Hobart 3225DX manual Panel, Front w/Components -1 Item

Page 55

 

Item

Dia.

Part

Description

Quantity

 

No.

Mkgs.

No.

 

 

 

 

Figure 11-2. Panel, Front w/Components (Fig 11-1 Item 104)

 

 

 

 

 

. . . 1 . . . . S3

114 193

. . SWITCH, range (Fig 11-3)

. . . 1

. . . 2 . . . . R1

605 960

. . RHEOSTAT, WW 300W 34 ohm

. . . 1

. . .

3 . . .

MS . . . . .

011 072

. . . . SWITCH, magnetic (consisting of)

. . . 1

. . . . . . . . .

. F

*048 317

. . . . . FUSE, mintr gl 14A 32V

. . . 1

. . .

4 . . .

. . . . . . . . . . . .

011 609

. . SWITCH, tgl SPDT 15A 125V

. . . 1

. . .

5 . . .

. . . . . . . . . . . .

032 897

. . RECEPTACLE, twlk grd 2P3W 15A 125V

. . . 1

. . . 6 . . CB1,2

139 266

. . CIRCUIT BREAKER, man reset 1P 15A 250VAC

. . . 2

. . .

7 . . . RC1

604 103

. . RECEPTACLE, str dx grd 2P3W 15A 250V

. . . 1

. . . . . . . . .

. . . . . . . . . . . .

025 234

. . PLUG, str grd 2P3W 15A 250V

. . . 1

. . .

8 . . . RC2

170 901

. . RECEPTACLE, str dx grd 2P3W 15A 125V

. . . 1

. . .

. . . . . .

. . . . . . . . . . . .

073 690

. . PLUG, str grd 2P3W 15A 125V Arrow Hart 5965V

 

. . .

9 . . .

. . . . . . . . . . . .

601 836

. . NUT, brs hex .250-20 jam hvy

. . . 3

. . . 10 . . .

. . . . . . . . . . . .

083 030

. . STUD, brs grd .250-20 x 1.750

. . . 1

. . . 11 . . .

.. .. .. .. .. .. .. .. .. .. . .

. . . . . . . . .

. . PLATE, ident control rating (order by model and serial number) . . .

. . . 1

. . . 12 . . .

046 559

. . METER, amp DC 50MV 0-500

. . . 1

. . . 13 . . .

. . . . . . . . . .

046 654

. . METER, volt DC 0-100

. . . 1

. . . 14 . . .

.. .. .. .. .. .. .. .. .. .. . .

021 385

. . BOOT, toggle switch lever

. . . 1

. . . 15 . . .

129 860

. . GAUGE, oil pressure

. . . 1

. . . . . . . . .

. . . . . . . . . .

128 829

. . KIT, oil line 44.000 in 1/8NPT x 10mm

. . . 1

. . . . . . . . .

. . . . . . . . . .

128 633

. . FITTING, pipe brs adapter 1/8NPT x 12mm

. . . 1

. . . 16 . . .

. . . . . . . . . .

129 837

. . GAUGE, engine pressure

. . . 1

. . . 17 . . .

. . . . . . . . . . . .

119 014

. . LEVER, switch black

. . . 1

. . . 20 . . .

. . . . . . . . . . . .

082 788

. . HOLDER, light ind

. . . 2

. . . 19 . .

PL1,2

*048 155

. . BULB, incand flg base 12V

. . . 2

. . . 18 . . .

. . . . . . . . . . . .

082 789

. . LENS, light ind red

. . . 2

. . . 21 . . .

HM

145 247

. . METER, hour 4-40VDC

. . . 1

. . . 22 . . .

. . . . . . . . . . . .

148 723

. . KNOB, pointer

. . . 1

. . . 23 . . .

. . . . . . . . . . . .

019 754

. . HANDLE, switch range

. . . 1

. . . 24 . . .

. . . . . . . . . . . .

. . . . . . . . .

. . NAMEPLATE, (order by model and serial number)

. . . 1

. . . 25 . . .

. S1

176 606

. . SWITCH, ignition 4posn

. . . 1

. . . 26 . . .

. . . . . . . . . . . .

127 618

. . PANEL, front upper

. . . 1

. . . 27 . . .

. . . . . . . . . . . .

189 404

. . SPACER, nylon

. . . 1

OPTIONAL *Recommended Spare Parts.

BE SURE TO PROVIDE MODEL AND SERIAL NUMBER WHEN ORDERING REPLACEMENT PARTS.

OM-130 098 Page 51

Image 55
Contents August OM-130Processes Visit our website atFrom Hobart to You Table of Contents Page ARC Rays can burn eyes and skin Symbol UsageArc Welding Hazards Electric Shock can killEngine Hazards Engine Heat can cause fire Battery Explosion can BlindMoving Parts can cause injury Engine Exhaust Gases can killARC Welding can cause interference Principal Safety StandardsEMF Information Radiation can cause interferenceLES Fumé ES ET LES GAZ peuvent ê tre dangereux Signification des symbolesConsignes DE SÉ Curité Lire Avant Utilisation UN Choc É Lectrique peut tuerLE Bruit peut affecter l’ouïe LE Soudage peut provoquer un in- cendie ou une explosionDES Particules Volantes peuvent blesser les yeux DES PIÈ CES Chaudes peuvent provoquer des brû lures gravesLA Chute DE L’APPAREIL peut blesser DES Organes Mobiles peuvent provoquer des blessures’EXPLOSION DE LA Batterie peut LA Chaleur DU Moteur peut pro- voquer un incendieConsignes relatives aux stimulateurs cardiaques Principales normes de sé curitéInformation sur les champs é lectromagné tiques LE Soudage À L’ARC risque de provoquer des interfé rencesDefinitions Symbols And DefinitionsWeld, Power, And Engine Specifications SpecificationsDimensions, Weights, And Operating Angles 40% Duty Cycle At 400 Amperes Warranty Minutes Welding Minutes RestingFuel Consumption Duty Cycle And OverheatingVolt-Ampere Curves AC Auxiliary PowerOptional AC Power Plant Curves Installing Welding Generator InstallationInstalling Muffler Pipe For 12 Minutes Activating The Dry Charge BatteryDo not overfill battery cells Vent CapsFull Connecting The BatteryEngine Prestart Checks Connect Negative Cable LastConnecting To Weld Output Terminals Installing Ether Cylinder Optional Ether Starting AidPut cap on fitting when cylinder is removed 100 ft 30 m Or Less Selecting Weld Cable Sizes10 100% Duty Cycle OM-130 098 Controls See Section Operating the Welding GeneratorRemote A/V Control Description Of Front Panel Controls See SectionVolt And 240 Volt Duplex Receptacles Operating Auxiliary EquipmentGfci Receptacle Option Optional Auxiliary Power ReceptaclesAustralian, British, And South African Receptacle Options Connecting Optional Auxiliary Power Plant Maintenance and Troubleshooting Maintenance Label Hose Servicing Air CleanerTo clean air filter Stop engineTo change oil and filter Servicing Fuel And Lubrication SystemsTo replace primary fuel filter Standard Models Adjusting Engine SpeedModels With Automatic Idle Optional Full Empty Overload Protection Servicing Optional Ether Starting AidTroubleshooting Inspecting And Cleaning Optional Spark ArrestorWelding Maximum see Section Auxiliary PowerCheck connections to auxiliary power plant see Section EngineCircuit Diagram For Welding Generator Electrical DiagramWetstacking RUN-IN ProcedureFrom flammables Run-In Procedure Using Load BankStop engine Do not touch hot exhaust Bank/gridRun-In Procedure Using Resistance Grid Selecting Equipment Auxiliary Power GuidelinesGrounding Generator To Truck Or Trailer Frame Amperes x Volts = Watts Grounding When Supplying Building SystemsHow Much Power Does Equipment Require? Earth ground if supplyingFarm/Home Equipment Rating Starting Watts Running Watts Approximate Power Requirements For Industrial MotorsApproximate Power Requirements For Farm/Home Equipment Industrial Motors Rating Starting Watts Running WattsContractor Rating Starting Watts Running Watts Approximate Power Requirements For Contractor EquipmentKVA/HP x HP x Power Required To Start MotorHow Much Power Can Generator Supply? Single-Phase Induction Motor Starting Requirements120 Single-Phase Power Company ServiceObtain and install correct switch Safety practicesCurrent Load Watts Amperes Selecting Extension Cord Use Shortest Cord Possible110 Parts List118 117 116 115 71Includes 113 11465 FIG Dia Part Description Quantity Mkgs 126 102 Optional Equipment Panel, Front w/Components Panel, Front w/Components -1 Item 11 10 GeneratorGenerator -1 Item Includes 114Support ServiceHobart Welding Products Contact your Distributor forCall

3225DX specifications

The Hobart 3225DX is a robust and versatile commercial dishwasher designed to meet the needs of restaurants, catering services, and institutions requiring efficient dishwashing solutions. Engineered for high performance, this machine combines advanced technology with user-friendly features to deliver exceptional cleaning results.

One of the standout features of the Hobart 3225DX is its high capacity. It can wash up to 60 racks per hour, making it suitable for busy kitchens. The machine is designed to handle a wide variety of dishware, glassware, and utensils, ensuring a thorough clean for all types of kitchenware.

Equipped with a powerful two-speed wash pump, the Hobart 3225DX guarantees optimal cleaning efficiency. Users can choose between a standard wash cycle for regular soiled items and a more intense cycle for heavily soiled dishware. This flexibility allows kitchen staff to adjust the machine's performance based on their specific needs.

The dishwasher features an advanced filtration system that minimizes the need for frequent cleaning of the internal components. This system captures food particles and debris, enhancing the machine's longevity and maintaining consistently clean results. Additionally, the Hobart 3225DX is designed with a built-in booster heater that increases water temperature to ensure optimal sanitization, complying with health and safety standards.

User convenience is a key consideration in the design of the Hobart 3225DX. The intuitive controls and clear display make operation straightforward, even for first-time users. The machine is also engineered for easy maintenance, with accessible components that allow for quick service and troubleshooting.

Another notable characteristic is its energy efficiency. The Hobart 3225DX is designed to minimize water and energy consumption without compromising performance. This aligns with the growing emphasis on sustainability in the foodservice industry, offering an eco-friendly solution that helps businesses reduce operational costs.

In summary, the Hobart 3225DX is an efficient, high-capacity commercial dishwasher that combines powerful cleaning capabilities with user-friendly features. Its advanced wash pump, effective filtration system, and energy-efficient design make it an ideal choice for any busy kitchen looking to streamline dishwashing operations and maintain the highest hygiene standards.