4-9. Troubleshooting

 

 

 

 

 

 

 

 

 

 

Trouble

Remedy

 

 

No weld output; wire does not feed.

Be sure line disconnect switch is On (see Section 2-13).

 

 

 

 

 

Replace building line fuse or reset circuit breaker if open (see Section 2-13).

 

 

 

 

 

Reset circuit breaker CB1 (see Section 4-2).

 

 

 

 

 

Secure gun trigger connections (see Section 2-6).

 

 

 

 

 

Have Factory Authorized Service Agent check Power switch.

 

 

 

 

 

Have Factory Authorized Service Agent check all board connections and main control board.

 

 

 

 

 

H – – message appears on voltmeter display to indicate thermostat TP1 is open and unit is in an over-

 

 

heated condition (see Section 3-2).

 

 

No weld output; wire feeds.

Thermostat TP1 open (overheating). Allow fan to run; the thermostat will close when the unit has cooled

 

 

(see Section 2-2).

 

 

 

 

 

Connect work clamp to get good metal to metal contact.

 

 

 

 

 

Replace contact tip (see Section 4-4).

 

 

 

 

 

An overload condition occurred. Release gun trigger (see Section 4-3).

 

 

 

 

 

Have Factory Authorized Service Agent check main control board and main rectifier.

 

 

Low weld output.

Connect unit to proper input voltage or check for low line voltage (see Section 2-13).

 

 

 

 

 

Check input voltage jumper links and correct position if necessary (see Section 2-11).

 

 

 

 

 

Have Factory Authorized Service Agent check main control board.

 

 

Fan motor does not run.

Have Factory Authorized Service Agent check fan-on-demand circuit.

 

 

Low, high, or erratic wire speed.

Readjust front panel settings (see Section 3-1).

 

 

 

 

 

Change to correct size drive rolls (see Section 4-5).

 

 

 

 

 

Readjust drive roll pressure (see Section 2-14).

 

 

 

 

 

Replace inlet guide, contact tip, and/or liner if necessary (see Sections 4-4, and 4-7).

 

 

 

 

 

Check position of input jumper links (see Section 2-11).

 

 

 

 

 

Have Factory Authorized Service Agent check main control board.

 

 

No wire feed.

Reset circuit breaker CB1 (see Section 4-2).

 

 

 

 

 

Turn Wire Speed control to higher setting (see Section 3-1).

 

 

 

 

 

Clear obstruction in gun contact tip or liner (see Sections 4-4, and 4-7).

 

 

 

 

 

Readjust drive roll pressure (see Section 2-14).

 

 

 

 

 

Change to correct size drive rolls (see Section 4-5).

 

 

 

 

 

Rethread welding wire (see Section 2-14).

 

 

 

 

 

Check gun trigger and leads. Repair or replace gun if necessary.

 

 

 

 

 

Have Factory Authorized Service Agent check main control board.

 

 

 

 

 

H – – message appears on voltmeter display to indicate thermostat TP1 is open and unit is in an over-

 

 

heated condition (see Section 3-2).

 

 

 

 

 

OM-198 683 Page 25

Image 29
Contents Description OM-198 683CProcesses From Hobart to You Table of Contents Page Marks a special safety message Symbol UsageArc Welding Hazards Electric Shock can killWelding can cause fire or explosion ARC Rays can burn eyes and skinFlying Metal can injure eyes Buildup of GAS can injure or killPrincipal Safety Standards About Pacemakers EMF InformationConsignes DE Securite Lire Avant Utilisation Signification des symbolesUN Choc É Lectrique peut tuer LES Fumé ES ET LES GAZ peuvent ê tre dangereuxLE Bruit peut affecter l’ouïe LE Soudage peut provoquer un incendie ou une explosionDES Particules Volantes peuvent blesser les yeux LA Chute DE L’APPAREIL peut blesser Risque D’INCENDIE OU’EMPLOI Excessif peut DES Organes Mobiles peuvent provoquer des blessuresConsignes relatives aux stimulateurs cardiaques Principales normes de sé curitéInformation sur les champs é lectromagné tiques Specifications InstallationWelding Power Source Duty Cycle And Overheating Exceeding duty cycle can damage unit and void warrantyDefinition Welding Gun Duty Cycle And OverheatingVolt-Ampere Curves Connecting Olympic 30A Gun Installing Work ClampInstalling Welding Gun Installing Gas Supply Setting Gun Polarity For Wire TypePositioning Jumper Links Installing Wire Spool and Adjusting Hub TensionSelecting a Location And Connecting Input Power Electrical Service GuideScale Threading Welding WireWeld Parameter 196 Controls OperationPower Up Status Voltmeter And Wire Feed Speed Meter OperationError Message Welding StatusRoutine Maintenance Maintenance &TROUBLESHOOTINGCircuit Breaker CB1 Unit OverloadReplacing Gun Contact Tip Changing Drive Roll and Wire Inlet GuideTurn Off power Aligning Drive Rolls and Wire Guide To Reassemble Gun Cleaning Or Replacing Gun LinerDisconnect gun from unit first Disconnect gun first Replacing Switch And/Or Head TubeTrouble Remedy TroubleshootingOM-198 683 Circuit Diagram Electrical DiagramMain Assembly Parts ListDia Part Description Mkgs Quantity Baffle, Center w/Components Baffle, Center w/Components -1 Item M-25 Gun M-25 Gun -1 Item Panel, Front w/Components -1 Item Wire Drive And Gears Wire Drive And Gears -2 ItemPanel, Rear w/Components -1 Item Drive Roll And Wire Guide KitsPage Page Support ServiceHobart Welding Products Contact your Distributor for