Carrier 50TCQA Pwrd C.O, 56/59, 65/69, 74/80, 81/88, 48/50, 53/56, 58/62, 71/77, 46/48, 55/59

Page 37

Table 10 — Unit Wire/MOCP Sizing Data (cont)

 

--- HZ

 

ELECTRIC HEATER

 

 

 

 

w/ PWRD C.O.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIT

V--- PH

IFM

 

 

 

NO P.E.

 

 

 

w/ P.E. (pwrd fr/unit)

 

Nom

 

 

 

 

 

 

 

 

 

 

 

TYPE

 

 

 

 

 

 

 

 

 

 

 

FLA

 

 

 

DISC. SIZE

 

 

 

DISC. SIZE

 

NOM.

 

(kW)

MCA

MOCP

 

MCA

 

MOCP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FLA

LRA

 

FLA

LRA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

126

 

 

 

 

 

 

---60

 

---

---

35.5

50

 

36

37.4

 

50

38

128

 

 

3.3/4.4

15.9/18.3

55.4/58.4

60/60

 

54/57

142/144

57.3/60.3

 

60/70

56/59

144/146

 

---1

STD

4.9/6.5

23.5/27.1

64.9/69.4

70/80

 

63/67

150/153

66.8/71.3

 

70/80

65/69

152/155

 

208/230

6.5/8.7

31.4/36.3

74.7/80.9

80/90

 

72/77

157/162

76.6/82.8

 

80/90

74/80

159/164

 

 

 

 

 

 

 

 

 

 

 

 

7.9/10.5

37.9/43.8

82.9.90.2

90/100

 

79/86

164/170

84.8/92.1

 

90/100

81/88

166/172

 

 

 

9.8/13.0

46.9/54.2

94.1/103.2

100/110

 

90/98

220/234

96.0/105.1

 

100/110

92/100

222/236

 

 

 

 

 

 

 

 

 

102

 

 

 

 

 

 

 

 

---

---

29.6

40

 

30

31.5

 

40

32

104

 

 

 

3.3/4.4

9.2/10.6

41.1/42.9

50/50

 

41/42

111/113

43.0/44.8

 

50/50

43/45

113/115

 

 

STD

4.9/6.5

13.6/15.6

46.6/49.1

50/50

 

46/48

116/118

48.5/51.0

 

50/60

48/50

118/120

 

 

6.5/8.7

18.1/20.9

52.2/55.7

60/60

 

51/54

120/123

54.1/57.6

 

60/60

53/56

122/125

 

 

 

 

 

 

 

 

7.9/10.5

21.9/25.3

57.0/61.2

60/70

 

55/59

124/127

58.9/63.1

 

60/70

58/62

126/129

 

 

 

12.0/16.0

33.4/38.5

71.4/77.7

80/80

 

69/75

135/141

73.3/79.6

 

80/80

71/77

137/143

 

 

 

 

 

 

 

 

 

114

 

 

 

 

 

 

---60

 

---

---

27.4

40

 

28

29.3

 

40

30

116

 

 

3.3/4.4

9.2/10.6

38.9/40.7

45/50

 

38/40

123/125

40.8/42.6

 

50/50

40/42

125/127

 

---3

MED

4.9/6.5

13.6/15.6

44.4/46.9

50/50

 

43/46

128/130

46.3/48.8

 

50/50

46/48

130/132

 

208/230

6.5/8.7

18.1/20.9

50.0/53.5

60/60

 

49/52

132/135

51.9/55.4

 

60/60

51.54

134/137

 

 

 

 

 

 

 

 

 

 

 

 

7.9/10.5

21.9/25.3

54.8/59.0

60/60

 

53/57

136/139

56.7/60.9

 

60/70

55/59

138/141

 

 

 

12.0/16.0

33.4/38.5

69.2/75.5

70/80

 

66/72

147/153

71.1/77.4

 

80/80

68/74

149/155

 

 

 

 

 

 

 

 

 

125

 

 

 

 

 

 

 

 

---

---

27.4

40

 

28

29.3

 

40

30

127

50TCQ*04

 

 

3.3/4.4

9.2/10.6

38.9/40.7

45/50

 

38/40

134/136

40.8/42.6

 

50/50

40/42

136/138

 

HIGH

4.9/6.5

13.6/15.6

44.4/46.9

50/50

 

43/46

139/141

46.3/48.8

 

50/50

46/48

141/143

 

 

 

 

 

 

6.5/8.7

18.1/20.9

50.0/53.5

60/60

 

49/52

143/146

51.9/55.4

 

60/60

51/54

145/148

 

 

 

 

 

 

 

 

7.9/10.5

21.9/25.3

54.8/59.0

60/60

 

53/57

147/150

56.7/60.9

 

60/70

55/59

149/152

 

 

 

12.0/16.0

33.4/38.5

69.2/75.5

70/80

 

66/72

158/164

71.1/77.4

 

80/80

68/74

160/166

 

 

 

 

 

 

 

 

 

55

 

 

 

 

 

 

 

 

---

---

18.2

25

 

19

19.2

 

25

20

56

 

 

 

6.0

7.2

27.2

30

 

27

62

28.2

 

30

28

63

 

 

STD

8.8

10.6

31.5

35

 

31

66

32.5

 

35

32

67

 

 

 

11.5

13.8

35.5

40

 

35

69

36.5

 

40

36

70

 

 

 

14.0

16.8

39.2

40

 

38

72

40.2

 

45

39

73

 

 

 

 

 

 

 

 

 

56

 

 

 

 

 

 

60

 

---

---

12.8

15

 

13

13.8

 

20

14

57

 

 

6.0

7.2

21.8

25

 

21

63

22.8

 

25

22

64

 

3---

 

 

 

 

MED

8.8

10.6

26.1

30

 

25

67

27.1

 

30

26

68

 

---

 

 

 

 

11.5

13.8

30.1

35

 

29

70

31.1

 

35

30

71

 

460

 

 

 

 

 

14.0

16.8

33.8

35

 

32

73

34.8

 

35

33

74

 

 

 

 

 

 

 

 

 

 

 

 

 

 

62

 

 

 

 

 

 

 

 

---

---

12.8

15

 

13

13.8

 

20

14

63

 

 

 

6.0

7.2

21.8

25

 

21

69

22.8

 

25

22

70

 

 

HIGH

8.8

10.6

26.1

30

 

25

73

27.1

 

30

26

74

 

 

 

11.5

13.8

30.1

35

 

29

76

31.1

 

35

30

77

 

 

 

14.0

16.8

33.8

35

 

32

79

34.8

 

35

33

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60

STD

---

---

7.1

15

 

7

7

9.5

 

15

9

9

 

3---

MED

---

---

5.1

15

 

5

10

7.5

 

15

7

12

 

---

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

575

HIGH

---

---

4.6

15

 

5

14

7.0

 

15

7

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: See page 44 for table legend and notes.

50TCQA

37

Image 37
Contents Installation Instructions 50TCQA Unit Dimensional Drawing 04 07 Size Units Plan for Unit Location Unit Dimensional Drawing 04 07 Size UnitInspect unit Plan for Sequence of Unit InstallationProvide Unit Support Roof Curb Details Rig and Place Unit Field Fabricate DuctworkInstall Outside Air Hood Ductwork when requiredEconomizer Hood Removal and Setup Factory Option Convert to Horizontal and ConnectDamper Assembly Two Position Damper Hood Removal and Setup Factory OptionEconomizer Hood and Two-Position Hood Install External Condensate Trap and LineMake Electrical Connections Field Power SupplyConvenience Outlets Units with Factory-Installed DisconnectSplice BLU + Factory-Option Thru-Base Connections460 480 H2 + H3 575 600Heat Anticipator Settings Field Control WiringUnits without Thru-Base Connections ThermostatHeater Model Number Electric HeatersTypical Module Installation PremierLink Controller PremierLinkt Factory-OptionPremierLink Wiring Schematic 55 Space Temperature Sensor Wiring Space Thermostat Connections PremierLink Sensor Usage Thermostat Mode Space Sensor ModeEconomizer controls Outside and Return Air Enthalpy Sensor WiringIndoor CO2 Sensor 33ZCSENCO2 Connections PremierLink Filter Switch Connection Color Code Recommendations Recommended Cables2413 or American A22503 Belden 8772 Columbia 02525RTU-MP Multi-Protocol Control Board RTU-MP control systemRTU-MP System Control Wiring Diagram RTU-MP Controller Inputs and Outputs 33ZCT59SPT Economizer controls Space Temperature SPT SensorsFan Status Connecting Discrete Inputs Filter StatusCommunication Wiring Protocols General Power Exhaust outputDS = Dip Switch BACnet MS/TP SW3 example shown Remote OccupancyRTU-MP Troubleshooting Communication LEDs Local AccessController SystemLEDs LEDs on the RTU-MP show the status of certain functionsSmoke Detector Locations Controller AssemblyTypical Return Air Detector Location Completing Installation of Return Air Smoke SensorUnit Wire/MOCP Sizing Data 56/59 Pwrd C.O65/69 74/8044/46 74/7949/52 79/8679/85 61/6455/58 72/7879/84 70/7469/75 43/4684/90 75/7952/54 61/6557/61 47/5070/76 82/9062/66 53/5576/82 88/95EconoMi$er IV Occupancy Switch Adjust Factory-Installed OptionsSmoke Detectors Pre-Start and Start-Up Install Accessories50TCQA 50TCQA Catalog No 50TCQ---01SI

50TCQA specifications

The Carrier 50TCQA is a split system air conditioner known for its efficiency, reliability, and innovative technology. Designed for commercial and residential applications, this model provides a solution that combines comfort with cost-effectiveness, making it a popular choice for homeowners and businesses alike.

One of the key features of the Carrier 50TCQA is its impressive SEER (Seasonal Energy Efficiency Ratio) rating, which ensures optimal energy efficiency. This means that users can enjoy lower utility bills while maintaining a comfortable indoor climate. The unit is engineered to perform well even in extreme temperatures, providing effective cooling and heating when needed.

This model employs a scroll compressor, which is known for its durability and quiet operation. The compressor's design allows for smoother operation and reduced noise levels, making it suitable for use in noise-sensitive environments. Additionally, the 50TCQA is equipped with a multi-speed fan, allowing for adjustable airflow to match the specific comfort requirements of different spaces.

The Carrier 50TCQA utilizes advanced refrigerant technology, specifically the environmentally friendly R-410A refrigerant. This refrigerant helps to reduce greenhouse gas emissions and provides efficient cooling without depleting the ozone layer. The unit's design is also focused on minimizing refrigerant leaks, ensuring environmental safety and reliability over the long term.

Ease of installation and maintenance is another significant characteristic of the Carrier 50TCQA. The unit features a compact and lightweight design, making it easier for technicians to install and service. Moreover, the system is equipped with diagnostic capabilities that allow for quick identification of issues, enhancing service efficiency and reducing downtime.

In terms of control, the Carrier 50TCQA offers a sophisticated thermostat option that includes programmable settings. Users can easily set desired temperatures, timers, and operating modes, ensuring optimal comfort throughout the day and night.

Overall, the Carrier 50TCQA presents a robust solution for climate control needs. With its energy-efficient performance, advanced technologies, and user-friendly features, it embodies Carrier's commitment to providing high-quality heating and cooling solutions that cater to modern lifestyle requirements. This model stands out as an excellent option for those looking to invest in a reliable HVAC system that enhances comfort while being mindful of energy consumption and environmental considerations.