3.4 CEILING UNIT -- DUCTED SYSTEMS

3.4.1 Filter Removal

The filters (Figure 3-9) are located in the ceiling grill. To remove the filters, do the following:

a. Grasp the edge of the filter at recess in the end of the ceiling grill.

b. Pull filter completely out of the filter slot.

c. Vacuum filter or wash filter in luke--warm water. Shake off excess water and dry thoroughly.

d. Replace filter by sliding the filter into the filter slot in the ceiling grill until the filter frame is flush with the in- terior grill.

Filters

Operation Indicators

Figure 3-9 Filter Removal -- Ducted Unit 3.4.2 Ceiling Grill Removal

To remove the ceiling grill (Figure 3--10) do the following:

a. Before working on unit place the master switch in the OFF position and disconnect all electrical power.

b. Remove filters (Refer to paragraph 3.4.1).

c.Remove 4 screws located on the ceiling grill, (two are under the filters) making sure to support the weight of the grill.

d.Lower the ceiling grill from the ceiling panel.

e.To replace the grill, place the grill up against the ceil- ing panel and align the screw holes in the grill with the ceiling panel.

f.Replace 4 screws and 2 filters.

3.4.3 Control Box Assembly Removal

To remove the control box assembly (Figure 3-11 & Figure 3-12) do the following:

a. Remove ceiling grill. Refer to paragraph 3.4.2.

b. Disconnect 115 volt (AC) and 12 volt (DC) power wires.

c. Remove two screws securing control box cover to control box assembly. See Figure 3-11.

d. Remove control box assembly cover.

Mounting Screws

Figure 3-10 Ceiling Grill -- Ducted

e. Disconnect blue furnace wires.

f.Unplug two connectors from upper unit.

g.Unplug DC power plug #1 (red/yellow/black wires) See Figure 3-12

h.Unplug relay signal plug #2 (brown/red/orange/ yellow wires). See Figure 3-12

i.While supporting control box assembly remove two screws securing control box assembly to ducted ceil- ing unit.

j.Pull control box assembly from the ducted ceiling unit.

k.Reverse above procedure to reassemble.

Control Box

Control Box

Cover Screws

Fuse

PCB Cover

PCB Cover

Screws

Figure 3-11 Control Box & PCB Cover

T--298

3-4

Image 28
Contents Model AirV AirV Safety Summary General Safety NoticesOperating Precautions Maintenance PrecautionsSpecific Warning and Caution Statements Specific Warnings and CautionsSafety 298 Table of Contents Table of Contents List of Figures Figure NumberList of Tables Table NumberSection Description IntroductionSerial Number Identification Design Change DescriptionsUpper Unit Roof Ceiling UnitMANUAL--FORM no Equipment Covered Type of Manual Additional Support ManualsFor Part no Ceiling Unit Component Identification Free--Blow Component Identification -- Low Profile -- Upper Unit Component Listing--Ceiling Unit For Ducted Systems Supply AIR Return AIRFree Blow Type START--UP CationsRefrigerant CYCLE--STANDARD System Refrigerant Flow Schematic -- Heat Pump -- Cool Mode Cooling Refrigerant Cycle -- Heat PumpPage Section Troubleshooting Heater Cycles on Limit Switch HEAT/ Cool Version only Insufficient COOLING, Cooling AIR not AdequateCondenser AIR not Adequate Insufficient CoolingClearing Diagnostic Alarms Inadequate Heat HEAT--PUMPPriority Malfunction Preventative Maintenance Section Service and MaintenanceService -- General Ceiling Grill -- Free Blow 3.3.3 Ceiling Panel Removal Indoor Thermostat Removal Indoor Thermostat 3.3.7 Air Sweep RemovalCeiling Unit -- Ducted Systems Control Box Assembly RemovalFilter Removal PCB Display Removal Service -- Upper Unit -- STANDARD, HC & HPFuse Removal Compressor Replacement 15 Control BoxUpper Scroll Assembly Removal 19 Motor AssemblyAir Handling System Removal 23 Blower WheelLine Voltage -- 10% 27 Upper Scroll Assembly Locking Tabs b. & Screw Locations c 30 Condenser Fan Assembly Retaining Ring Condenser Motor Removal 34 Evaporator Motor Locking TabsCapacitor Removal Change from Fahrenheit to Celsius willBe permanent. It cannot be changed back to Fahrenheit38 Remote Control Components SET Thermostat Configuration LCD DisplayCheck Thermostat Operation Upper Unit Powerbox AssemblyThermostat Thermostat Powerbox Assembly Ac to ry Wiri ng Fie ld Wiri ngSection Wiring Schematics Upper Unit Schematic -- Standard & HCCeiling Unit Schematic -- Cooling Only Heat Pump -- Ceiling Unit -- Free Blow Heat Pump -- Upper Unit -- Ducted 10 Ceiling Unit -- Wall Thermostat -- Ducted & Free Blow Wall Mounted ThermostatsIndex Ceiling Unit -- Ducted Systems Ceiling Unit -- Free Blow