Carrier T--298 PCB Display Removal, Fuse Removal, Service -- Upper Unit -- STANDARD, HC & HP

Page 29

115V AC

 

 

 

 

12V DC

Fuse

 

#1

Upper Unit

#2

Furnace

Connectors

Wires (blue)

 

Figure 3-12 Control Box Assembly -- Ducted 3.4.4 Main PCB Board Removal

To remove the Main PCB board (Figure 3-13) do the following:

a. Remove ceiling grill. Refer to paragraph 3.4.2.

b. Remove three screws securing the PCB cover to the ducted ceiling unit.

c. Carefully turn over the PCB cover exposing the PCB main and the PCB display assemblies.

d.Gently push holding clip away from PCB main assem- bly.

e.Lift PCB main assembly from PCB cover assembly.

f.Unplug display wiring plug #4. Figure 3-13

g.Unplug thermistor/thermostat wiring plug #3. Figure 3-13

h.Unplug power wiring plug #1. Figure 3-12

i.Unplug signal wiring plug #2. Figure 3-12

j.Reverse above procedures for reassembly.

Holding Clips

PCB Display

PCB Main

#4

#3

Figure 3-13 Main/Display PCB’s

3.4.5 PCB Display Removal

To remove the PCB display assembly (Figure 3-13) do the following.

a. Remove ceiling grill. Refer to paragraph 3.4.2.

b. Push large clip away from PCB display assembly. c. Push center clip towards large clip.

d. Pull PCB display assembly from PCB cover.

e. Unplug display wiring from PCB main assembly.

f.Reverse above procedures of reassembly.

3.4.6 Fuse Removal

To remove the fuse (Figure 3-11) do the following: a. Remove ceiling grill. Refer to paragraph 3.4.2.

b.Turn fuse holder in direction of arrow (counter-- clock-- wise).

c.Pull fuse from fuse holder.

d.Test and/or replace.

e.Reverse above procedures for reassembly.

3.5SERVICE -- UPPER UNIT -- STANDARD, HC & HP

3.5.1 Exterior Cover Removal

CAUTION

Coil fins are sharp. Use care when removing the cover form the base pan to avoid per- sonal injury.

To remove the exterior cover, do the following:

a. Before working on unit place the master switch in the OFF position and disconnect all electrical power.

b. Remove 15 screws securing the unit cover to the base pan assembly. See Figure 3-14.

c.Carefully lift the exterior cover off of the unit base pan assembly.

d.Reverse above procedure for reassembly.

Cover Screws

Figure 3-14 Cover Assembly -- Standard

3-5

T--298

Image 29
Contents Model AirV AirV General Safety Notices Safety SummaryOperating Precautions Maintenance PrecautionsSpecific Warnings and Cautions Specific Warning and Caution StatementsSafety 298 Table of Contents Table of Contents Figure Number List of FiguresTable Number List of TablesIntroduction Section DescriptionSerial Number Identification Design Change DescriptionsCeiling Unit Upper Unit RoofFor Part no Additional Support ManualsMANUAL--FORM no Equipment Covered Type of Manual Ceiling Unit Component Identification Free--Blow Component Identification -- Low Profile -- Upper Unit Component Listing--Ceiling Unit For Ducted Systems Return AIR Supply AIRFree Blow Type Refrigerant CYCLE--STANDARD System CationsSTART--UP Refrigerant Cycle -- Heat Pump Refrigerant Flow Schematic -- Heat Pump -- Cool Mode CoolingPage Section Troubleshooting Insufficient COOLING, Cooling AIR not Adequate Heater Cycles on Limit Switch HEAT/ Cool Version onlyCondenser AIR not Adequate Insufficient CoolingInadequate Heat HEAT--PUMP Clearing Diagnostic AlarmsPriority Malfunction Service -- General Section Service and MaintenancePreventative Maintenance Ceiling Grill -- Free Blow 3.3.3 Ceiling Panel Removal Indoor Thermostat 3.3.7 Air Sweep Removal Indoor Thermostat RemovalFilter Removal Control Box Assembly RemovalCeiling Unit -- Ducted Systems Fuse Removal Service -- Upper Unit -- STANDARD, HC & HPPCB Display Removal 15 Control Box Compressor Replacement19 Motor Assembly Upper Scroll Assembly Removal23 Blower Wheel Air Handling System RemovalLine Voltage -- 10% 27 Upper Scroll Assembly Locking Tabs b. & Screw Locations c 30 Condenser Fan Assembly Retaining Ring 34 Evaporator Motor Locking Tabs Condenser Motor RemovalChange from Fahrenheit to Celsius will Capacitor RemovalBe permanent. It cannot be changed back to Fahrenheit38 Remote Control Components LCD Display SET Thermostat ConfigurationCheck Thermostat Operation Thermostat Powerbox AssemblyUpper Unit Ac to ry Wiri ng Fie ld Wiri ng Thermostat Powerbox AssemblyUpper Unit Schematic -- Standard & HC Section Wiring SchematicsCeiling Unit Schematic -- Cooling Only Heat Pump -- Ceiling Unit -- Free Blow Heat Pump -- Upper Unit -- Ducted Wall Mounted Thermostats 10 Ceiling Unit -- Wall Thermostat -- Ducted & Free BlowCeiling Unit -- Ducted Systems Ceiling Unit -- Free Blow Index