Hitachi 309379 warranty DTS Error Codes, After a fault, follow these steps to restart sprayer

Page 11

DTS Error Codes

No display does not mean that sprayer is not pressurized. Relieve pressure before repair; page 4.

DISPLAY

SPRAYER

INDICATION

ACTION

 

OPERATION

 

 

 

 

 

 

 

Engine runs. Pump stops.

Pressure exceeded

Correct over-pressure cause.

 

 

4900 psi (338 bar, 34 MPa)

Check transducer and control

 

 

 

board. Take to service center.

 

 

 

 

 

Engines runs. Pump operates. No

Pressure transducer faulty,

Check transducer connection.

 

pressure displays.

bad connection or broken

Open drain valve. Substitute

 

 

wire.

new transducer for transducer

 

 

 

in sprayer. If sprayer runs, re-

 

 

 

place transducer.

 

 

 

 

 

Engine runs. AutoClean timer cancels.

Pressure exceeded

Turn directional valve OFF

 

 

2000 psi (338 bar, 34 MPa)

 

(AutoClean)

 

while in AutoClean.

 

 

 

 

 

 

Engine runs. Setup is exited.

Pressure exceeded

Turn directional valve OFF,

(Setup)

 

500 psi (34 bar, 3.4 MPa)

then ON.

 

while in Setup.

 

 

 

 

 

 

Engine runs. Pump switch OFF

Normal condition

Turn pump switch ON.

 

 

 

Increase pressure.

 

 

 

 

After a fault, follow these steps to restart sprayer:

1.Correct fault condition

2.Turn pump switch OFF

3.Turn pump switch ON

309379 11

Image 11
Contents HydraMaxr Sprayers Repair PartsTable of Contents 309379309379 AdvertênciaHOT Surfaces Hazard Explosion Hazard General Repair InformationGrounding Moving Parts HazardSEMI-ANNUALLY MaintenancePressure Relief Procedure Injection HazardTroubleshooting Removal InstallationHydraulic Pump 141 Bottom View 6425 133 Engine mounting Fasteners 136 139 Fan Belt Removal InstallationRemoval InstallationPressure Control Display and Control BoardOperation GeneralDisplay Sprayer Indication Action Operation DTS Error CodesAfter a fault, follow these steps to restart sprayer Removal Do Fan Belt, Removal Do Fan Belt, InstallationEngine Top Green Red Hydraulic MotorDirectional Valve Removal Hydraulic Motor SwitchesPush retaining spring up push out pin Displacement PumpParts Drawing HydraMax 225 Sprayers Models 233640 Parts List HydraMax 225 Sprayers163 153 164 154 Spring Holder SpringFitting Ring106 Plug Parts Drawing HydraMax 300/350 Sprayers Model 233650 Parts List HydraMax 300/350 SprayersTi1390c Shield Ti1391a † Include in Hydraulic Seal Repair Kit Parts Drawing HydraMax 225/300/350 Sprayers Wiring DiagramParts List HydraMax 225/300/350 Sprayers Spray GUN HydraMax Sprayers with Spray Gun and HosesHydraMax 225, 300 and 350 Sprayers Models 233642, 233643, 233651GRACO-APPROVED Hydraulic OIL Technical DataDimensions Graco Phone Number AccessoriesFor Graco Canada Customers Graco WarrantyAdditional Warranty Coverage