Graco 16W865, ti23055a, 16W884, 16W881, 16W867 Press and hold DTS button to clear error code to zero

Page 18

Digital Tracking System (ProContractor and Ironman units)

Secondary Menu - Stored Data and WatchDog Pump Protection Modes

1.Perform Pressure Relief, steps 1 - 4 if they have not already been done.

2.Turn power switch on while holding DTS button down.

7.Short press DTS button. W-DOGscrolls past then OFF displays if watchdog switch is OFF. ON dis- plays if Watchdog switch is ON.

ti22719a

3.The sprayer model briefly displays (e.g. 5900), SERIAL NUMBER scrolls past and then serial num- ber (e.g. 00001) displays.

ti22720a

4.Short press DTS button and MOTOR ON scrolls past and then total motor run hours are displayed.

ti22721a

5.Short press DTS button. LAST ERROR CODE scrolls by and last error code is displayed; e.g. E=07. See sprayer Repair manual for additional information.

ti22722a

6.Press and hold DTS button to clear error code to zero.

ti22723a

ti22724a

8.Press and hold (8 seconds) DTS button to move to WatchDog Trigger % menu. Continue to hold DTS button and Watchdog can be set to trigger at 30, 40, 50, or 60% of current sprayer pressure setting. Release DTS button when desired % is displayed. default is 50%.

ti22725a

9. Short press to move to SOFTWARE REV.

ti22726a

18

332919C

Image 18
Contents Operation Table of Contents Fire and Explosion Hazard Equipment Misuse Hazard Component Identification Standard Models 3400, 3900, 5900, 5900HD, 7900, 7900HDProContractor Models 3900, 5900, 7900, 5900HD, 7900HD Ironman Models 5900, 7900, 7900HD Lo-Boy Models 3900, 5900 Convertible Models Pressure Relief Procedure Grounding Setup Convertible Models Only Change Engine to MotorStartup Switch Tip Guard Assembly Spray Clearing Tip Clogs WatchDog Protection System ProContractor and Ironman units only Hose Reel ProContractor units onlyChange Display Units Digital Tracking SystemProContractor and Ironman units Operation Main Menu Job GallonsPress and hold DTS button to clear error code to zero Cleanup Turn prime valve down Drain position Maintenance Pressure Relief ProcedureTroubleshooting Problem Cause SolutionTroubleshooting Troubleshooting Procedure Fluid Pump Runs ConstantlyControl Board Malfunction Control Board Malfunction Steps VoltsConvertible Electric Motor Will Not Run Convertible Electric Motor Will Not Run Steps See step Is there over 10-20 AC volts? Beep Digital Display Messages Two blinks is the same as E=02Pinion Assembly/Clutch Armature/Clamp Pinion Assembly/Clutch Armature RemovalInstallation Technical Data ModelsMetric Models Honda GX160 Engine Ansi Power Rating @ 3600 rpm Horsepower Honda GX200 Engine Ansi Power Rating @ 3600 rpm Horsepower Graco Standard Warranty Graco Information