Graco ti15035b, ti14838b, ti15034a, ti15036b important safety instructions Step

Page 15

Troubleshooting

TYPE OF PROBLEM

WHAT TO CHECK

HOW TO CHECK

 

 

 

Sprayer does not run at all

Control is commanding motor to run

1. Remove pump and try to run sprayer. If motor runs,

 

but motor shaft does not rotate.

check for locked or frozen pump or drive train.

Digital display shows E=05

Possibly locked rotor condition, an

If sprayer does not run, continue to step 2.

 

 

open connection exists between

2. Set sprayer to OFF and disconnect power to

 

motor and control, there is a

 

problem with motor or control board,

sprayer.

 

or motor amp draw is excessive.

3. Disconnect motor connector(s) from control board

 

 

Control board status light blinks

 

 

socket(s). Check that motor connector and control

5 times repeatedly

 

board contacts are clean and secure. If contacts

 

 

are clean and secure, continue to step 4.

 

 

4. Set sprayer to OFF and spin motor fan 1/2 turn.

 

 

Restart sprayer. If sprayer runs, replace control

 

 

board. If sprayer does not run, continue to step 5.

 

 

5. Perform Spin Test: Test at large 4-pin motor field

 

 

connector. Disconnect fluid pump from sprayer. Test

 

 

motor by placing a jumper across pins 1 & 2. Rotate

 

 

motor fan at about 2 revolutions per second. A cogging

 

 

resistance to motion should be felt at the fan.

 

 

The motor should be replaced if no resistance is felt.

 

 

Repeat for pin combinations 1 & 3 and 2 & 3. Pin 4

 

 

(the green wire) is not used in this test. If all spin test

 

 

is positive, continue to step 6.

 

 

Green Blue Red Black

STEP 1:

Green Blue Red Black

STEP 2:

Green Blue Red Black

STEP 3:

3A0157B

15

Image 15
Contents Mark Electric Airless SprayersUltra MAX lIl ModelsTable of Contents Extension Cords GroundingSkin Injection Hazard Fire and Explosion HazardMoving Parts Hazard Equipment Misuse HazardElectric Shock Hazard Pressurized Aluminum Parts HazardComponent Identification Pressure Relief Procedure Pails Power RequirementsGrounding Extension CordMechanical/Fluid Flow TroubleshootingPerform Pressure Relief Procedure What to Check What to do Type of ProblemFollow Pressure Relief Procedure on What to Check What to do Type of Problem Electrical Type of Problem What to Check HOW to CheckCheck to see if transducer and control board Step Check Motor Thermal Switch Unplug thermal Is not correct, replace motor YES Sprayer Will Not Shut OffSprayer Will Not Run Step VAC and 110 VAC Motor Control Board Removal Installation33 D 115 Removal VAC Filter BoardPressure Adjust Potentiometer Pressure Control Transducer Install control box 61 and control panel 68 with four screws 3A0157B Drive and Bearing Housing Replacement DisassemblyAssembly Drive and Bearing Housing Replacement Removal Motor ReplacementInstallation Install Motor ShroudMotor Replacement Perform Relieve Pressure Procedure Displacement Pump Replacement for 695/795/MarkTi7169a Perform Pressure Relief Procedure, Displacement Pump Replacement 1095/1595/MarkPlace u-bolt on pump door protrusion Attach drain hose to sprayer Hose Reel Grease shaft RemovalInstallation Reed Switch ReplacementWiring Diagram 120V ModelsON/OFF 120V Models with 15/20 Amp Switch Digital Display Potentiometer Pressure Transducer Thermal Switch Motor Leads SensorDip Switch AutoClean Watchdog 240V Models3A0157B Graco Information Graco Standard Warranty