Graco ti15035b, ti14838b, ti15034a, ti15036b Reed Switch Replacement, RemovalInstallation

Page 39

Reed Switch Replacement

Reed Switch Replacement

RemovalInstallation

1. Remove four screws and remove display cover.

ti13568a

1.Apply thread sealant to end of reed switch. Hand tighten reed switch until it is tight against control panel.

ti13574a

2.Add thread sealant and tighten jam nut against threaded bus.

2. Remove two screws and remove control panel.

ti13576a

3. Connect reed switch to control board.

ti13571a

3. Unplug reed switch from control board.

ti13572a

4. Replace control panel and tighten two screws.

ti13572a

4. Unscrew reed switch from control panel.

ti13571a

5. Replace display cover and tighten four screws.

ti13573a

ti13568a

3A0157B

39

Image 39
Contents Mark Electric Airless SprayersUltra MAX lIl ModelsTable of Contents Extension Cords GroundingSkin Injection Hazard Fire and Explosion HazardMoving Parts Hazard Equipment Misuse HazardElectric Shock Hazard Pressurized Aluminum Parts HazardComponent Identification Pressure Relief Procedure Pails Power RequirementsGrounding Extension CordMechanical/Fluid Flow TroubleshootingPerform Pressure Relief Procedure What to Check What to do Type of ProblemFollow Pressure Relief Procedure on What to Check What to do Type of Problem Electrical Type of Problem What to Check HOW to CheckCheck to see if transducer and control board Step Check Motor Thermal Switch Unplug thermal Is not correct, replace motor YES Sprayer Will Not Shut OffSprayer Will Not Run Step VAC and 110 VAC Motor Control Board Removal Installation33 D 115 Removal VAC Filter BoardPressure Adjust Potentiometer Pressure Control Transducer Install control box 61 and control panel 68 with four screws 3A0157B Drive and Bearing Housing Replacement DisassemblyAssembly Drive and Bearing Housing Replacement Removal Motor ReplacementInstallation Install Motor ShroudMotor Replacement Perform Relieve Pressure Procedure Displacement Pump Replacement for 695/795/MarkTi7169a Perform Pressure Relief Procedure, Displacement Pump Replacement 1095/1595/MarkPlace u-bolt on pump door protrusion Attach drain hose to sprayer Hose Reel Grease shaft RemovalInstallation Reed Switch ReplacementWiring Diagram 120V ModelsON/OFF 120V Models with 15/20 Amp Switch Digital Display Potentiometer Pressure Transducer Thermal Switch Motor Leads SensorDip Switch AutoClean Watchdog 240V Models3A0157B Graco Information Graco Standard Warranty