| Troubleshooting |
|
|
|
|
| Problem | What to Check | How to check |
|
|
|
|
| Sprayer does not run at all | Check voltage supply to the sprayer | Turn ON/OFF switch OFF and |
| AND | (control board is detecting a multiple | disconnect power to sprayer. |
| voltage surges). | Locate a good voltage supply to | |
| Display shows E=04 | ||
|
| ||
|
| prevent damage to electronics. | |
| OR |
| |
|
|
| |
| Control board status light blinks 4 |
|
|
| times repeatedly |
|
|
|
|
|
|
| Sprayer does not run at all | Control is commanding motor to run | 1.Remove pump and try to run |
| AND | but motor shaft does not rotate. | sprayer. If motor runs, check for |
| Possibly locked rotor condition, an | locked or frozen pump or drive train. | |
| Display shows E=05 | ||
| open connection exists between | If sprayer does not run, continue to | |
| OR | motor and control, there is a problem | step 2. |
| with motor or control board, or motor | 2.Turn ON/OFF switch OFF and | |
| Control board status light blinks 5 | ||
| amp draw is excessive. | ||
| disconnect power to sprayer. | ||
| times repeatedly |
| |
|
| 3.Disconnect motor connector(s) from | |
|
|
| |
|
|
| control board socket(s). Check that |
|
|
| motor connector and control board |
|
|
| contacts are clean and secure. If |
|
|
| contacts are clean and secure, |
|
|
| continue to step 4. |
|
|
| 4.Connect a DC voltmeter across the |
|
|
| two motor wires – red & black spin |
|
|
| the motor fan and check for a |
|
|
| voltage to register on the meter. If |
|
|
| voltage is not present, check |
|
|
| brushes. If OK, replace motor. If |
|
|
| voltage is present, go to step 5. |
|
|
| 5.Perform a spin test by connecting a |
|
|
| 9 |
|
|
| leads. Motor leads may vary in style |
|
|
| and size. Locate the two wires |
|
|
| going to the carbon brushes |
|
|
| normally Red and Black. Motor |
|
|
| should spin when battery is |
|
|
| connected to the motor leads. |
BLACK
RED (+)
YELLOW
334466A | 35 |