Troubleshooting
Sprayer Will Not Shut Off
1.Perform Pressure Relief Procedure, page 13. Leave prime valve open (down) and turn ON/OFF switch OFF.
2.Remove control box cover so the control board status light can be viewed if available.
Troubleshooting Procedure
Plumb pressure gauge into paint hose, plug sprayer in, and turn power switch ON. Does sprayer reach or exceed
its maximum pressure?
YES
Is the control board status light on?
YES
|
|
| Mechanical problem: |
|
|
| See the proper fluid pump |
NO |
|
| |
|
| manual for the sprayer for | |
|
|
| further troubleshooting procedures. |
|
|
|
|
|
|
| Replace the control board. |
NO |
|
| |
| |||
|
|
|
|
Unplug the transducer from control board.
Does motor stop running?
YES
Bad transducer.
Replace and test with a new one.
|
|
| Replace the control board. |
NO |
|
| |
| |||
|
|
|
|
ti24731a
334466A | 41 |