Graco 334466A important safety instructions Ti2824a

Page 25

Operation

3.Sprayer model number is displayed followed by Data Point 1 which is the unit power on time in hours.

4.Press display button again to display Data Point 2. Motor run time in hours is displayed.

5.Press display button again to display Data Point 3. This will be the last error code.

6.To erase last error code, press and hold display button.

7.Press display button again to display Data Point 4. The software revision is displayed.

8.Press display button again to return to Data Point 1.

9.Turn ON/OFF switch to OFF position to exit Stored Data.

ti24586a

ti2824a

334466A

25

Image 25
Contents Contractor/FTx Related ManualsSG3 334599Contents Stand Lo-Boy Hi-BoyModel Extension Cords GroundingFire and Explosion Hazard Equipment Misuse Hazard Personal Protective Equipment Stand Models Component IdentificationLo-Boy Models Hi-Boy Models Hi-Boy Models Grounding Power RequirementsExtension Cords PailsPressure Relief Procedure Trigger Lock 334466A SetupTi24638a Make certain ON/OFF switch is OFF Turn prime valve horizontal. Disengage trigger lock Startup Perform Pressure Relief Procedure,20 s Ti24652a Perform Pressure Relief Procedure, Spray Tip InstallationOperation SprayClear Tip Clog Digital Display Pressure Display Perform Pressure Relief Procedure,Stored Data Display Ti2824a Cleanup Raise fluid intake above flushing fluid Ti24719a Activity Interval MaintenanceMechanical/Fluid Flow TroubleshootingRefer to this column Clockwise position. If problem Properly installed to allow fullHolders Dust with a small cleaning brush Piston packings are worn orSpray tip is partially clogged Possible during primingFluid supply is low or empty Pump manual. Check fluid supplyElectrical Problem What to Check How to checkAre clean and secure Install new transducer. ConnectSprayer does not run at all Check transducer or transducer ConnectionsVolt battery to the motor Contacts are clean and secureSize. Locate the two wires Should spin when battery isOhms Board Motor thermal device When cool, correct causeDisplay shows E=06 Replace loose terminals crimp to Basic electrical problemsMotor. Check both brushes Rest squarely on top of brush Motor brushes may be bindingSprayer Will Not Run Sprayer Will Not RunStep Sprayer Will Not Shut Off Troubleshooting ProcedureStand Sprayers Torque Ref. Part Description Stand Sprayers Parts ListQty Models 17C315 Lo-Boy Sprayers6040 132 Models 17C315 Ref. Part Description Lo-Boy Sprayers Parts ListModels 17C317, 17C362, 17C408 Hi-Boy Sprayers40 44 117 Models 17C317, 17C362, 17C408 Ref. Part Description Hi-Boy Sprayers Parts ListAlert  Accessories and LabelsControl Box Grommet Control Box Parts List120V, US/Japan Wiring DiagramsTP1 TP2 110V, UKUltra 395 PC / Ultra 395 PC Classic Technical SpecificationsMetric Materials of Construction For Graco Canada Customers Graco Standard WarrantyInternational Offices Belgium, China, Japan, Korea Graco Information