Graco 334466A important safety instructions Electrical, Problem What to Check How to check

Page 33

Troubleshooting

Electrical

Symptom: Sprayer does not run, stops running, or will not shut off.

Perform Pressure Relief Procedure, page 13.

1.Plug sprayer into correct voltage, grounded outlet.

2.Turn the ON/OFF switch OFF wait 30 seconds and then turn power back ON again (this ensures sprayer is in normal run mode).

3.Turn pressure control knob clockwise 1/2 turn.

4.View digital display or remove control box cover to view control board status light. To determine which code (or any other code besides voltage supply) refer to the control board status light. Turn the ON/OFF switch OFF, remove the control cover then turn power back ON. Observe the status light. Blinking LED total count equals the error code (for example: two blinks equals CODE 02).

Keep clear of electrical and moving parts during troubleshooting procedures. To avoid electrical shock hazards when covers are removed for troubleshooting, wait 7 seconds after disconnecting power cord for stored electricity to dissipate.

Problem

What to Check

How to check

 

 

 

Sprayer does not run at all

See flow chart, page 39.

 

AND

 

 

Display is blank

 

 

OR

 

 

Control board status light never lights

 

 

 

 

 

Sprayer does not shut off

Control board.

Replace control board.

AND

 

 

Display shows E=02

 

 

OR

 

 

Control board status light blinks 2

 

 

times repeatedly

 

 

 

 

 

334466A

33

Image 33
Contents Contractor/FTx Related ManualsSG3 334599Contents Hi-Boy Stand Lo-BoyModel Extension Cords GroundingFire and Explosion Hazard Equipment Misuse Hazard Personal Protective Equipment Stand Models Component IdentificationLo-Boy Models Hi-Boy Models Hi-Boy Models Grounding Power RequirementsExtension Cords PailsPressure Relief Procedure Trigger Lock 334466A SetupTi24638a Make certain ON/OFF switch is OFF Turn prime valve horizontal. Disengage trigger lock Startup Perform Pressure Relief Procedure,20 s Ti24652a Perform Pressure Relief Procedure, Spray Tip InstallationOperation SprayClear Tip Clog Pressure Display Perform Pressure Relief Procedure, Digital DisplayStored Data Display Ti2824a Cleanup Raise fluid intake above flushing fluid Ti24719a Activity Interval MaintenanceTroubleshooting Mechanical/Fluid FlowRefer to this column Clockwise position. If problem Properly installed to allow fullHolders Dust with a small cleaning brush Piston packings are worn orSpray tip is partially clogged Possible during primingFluid supply is low or empty Pump manual. Check fluid supplyElectrical Problem What to Check How to checkAre clean and secure Install new transducer. ConnectSprayer does not run at all Check transducer or transducer ConnectionsVolt battery to the motor Contacts are clean and secureSize. Locate the two wires Should spin when battery isOhms Motor thermal device When cool, correct cause BoardDisplay shows E=06 Replace loose terminals crimp to Basic electrical problemsMotor. Check both brushes Rest squarely on top of brush Motor brushes may be bindingSprayer Will Not Run Sprayer Will Not RunStep Sprayer Will Not Shut Off Troubleshooting ProcedureStand Sprayers Torque Stand Sprayers Parts List Ref. Part DescriptionQty Models 17C315 Lo-Boy Sprayers6040 132 Models 17C315 Ref. Part Description Lo-Boy Sprayers Parts ListModels 17C317, 17C362, 17C408 Hi-Boy Sprayers40 44 117 Models 17C317, 17C362, 17C408 Ref. Part Description Hi-Boy Sprayers Parts ListAlert  Accessories and LabelsControl Box Grommet Control Box Parts List120V, US/Japan Wiring DiagramsTP1 TP2 110V, UKUltra 395 PC / Ultra 395 PC Classic Technical SpecificationsMetric Materials of Construction For Graco Canada Customers Graco Standard WarrantyInternational Offices Belgium, China, Japan, Korea Graco Information