Troubleshooting
Problem | What to Check | How to check |
8.Use an Ohm meter to check motor for shorts. Connect
|
| GROUND |
|
| BLACK |
|
| RED |
|
| YELLOW |
|
| OL |
|
| - |
|
| ti24724a |
|
| 9.Reconnect motor connector(s) to |
|
| control board socket(s). Connect |
|
| power, turn ON/OFF switch ON and |
|
| control knob to 1/2 turn clockwise. If |
|
| motor does not run, replace control |
|
| board. |
Sprayer does not run at all | Motor is hot or there is a fault in the | Allow sprayer to cool. If sprayer runs |
AND | motor thermal device. | when cool, correct cause of |
| overheating. Keep sprayer in cooler | |
Display shows E=06 |
| |
| location with good ventilation. Make | |
OR |
| sure motor air intake is not blocked. If |
| sprayer still does not run, replace | |
Control board status light blinks 6 |
| |
| motor. | |
times repeatedly |
|
|
Sprayer does not run at all | Check voltage supply to the sprayer | Turn ON/OFF switch OFF and |
AND | (incoming voltage too low for sprayer | disconnect power to the sprayer. |
operation). |
| |
Display shows E=08 |
| |
|
| |
OR |
|
|
Control board status light blinks 8 |
|
|
times repeatedly |
|
|
334466A | 37 |