Troubleshooting
Problem | What to Check | How to check | |
|
|
| |
Sprayer does not run at all | Check transducer or transducer | Make sure there is no pressure in the | |
AND | connections | system (see Pressure Relief | |
| Procedure, page 13). Check fluid | ||
Display shows E=02 |
| ||
| path for clogs, such as clogged filter. | ||
OR |
| Use airless paint spray hose with no | |
Control board status light blinks 2 |
| metal braid. A small hose or metal | |
| braid hose may result in | ||
times repeatedly |
| ||
| |||
|
| ||
|
| Turn ON/OFF switch OFF and | |
|
| disconnect power to sprayer. | |
|
| Check transducer and connections to | |
|
| control board. | |
|
| Disconnect transducer from control | |
|
| board socket. Check that transducer | |
|
| and control board contacts are clean | |
|
| and secure. | |
|
| Reconnect transducer to control | |
|
| board socket. Connect power, turn | |
|
| ON/OFF switch ON and control knob | |
|
| 1/2 turn clockwise. If sprayer does not | |
|
| run properly, turn ON/OFF switch | |
|
| OFF and go to next step. | |
|
| Install new transducer. Connect | |
|
| power, turn ON/OFF switch ON and | |
|
| control knob 1/2 turn clockwise. | |
|
| Replace control board if sprayer does | |
|
| not run properly. | |
|
|
| |
Sprayer does not run at all | Check transducer or transducer | Turn ON/OFF switch OFF and | |
AND | connections (control board is not | disconnect power to sprayer. | |
detecting a pressure signal). | Check transducer and connections to | ||
Display shows E=03 | |||
| |||
| control board. | ||
OR |
| ||
| Disconnect transducer from control | ||
Control board status light blinks 3 |
| ||
| board socket. Check to see if | ||
times repeatedly |
| transducer and control board contacts | |
|
| are clean and secure. | |
|
| Reconnect transducer to control | |
|
| board socket. Connect power, turn | |
|
| ON/OFF switch ON and control knob | |
|
| to 1/2 turn clockwise. If sprayer does | |
|
| not run, turn ON/OFF switch OFF and | |
|
| go to next step. | |
|
| Connect a confirmed working | |
|
| transducer to control board socket. | |
|
| Turn ON/OFF switch ON and control | |
|
| knob to 1/2 turn clockwise. If sprayer | |
|
| runs, install new transducer. Replace | |
|
| control board if sprayer does not run. | |
|
|
|
34 | 334466A |