Graco 16F887 16H240, 262612, 16H241, 16H243, 16H245, 16H242, 16H829 Sprayer Setup

Page 12

Sprayer Setup

This sprayer arrives from the factory with a small amount of test material in the system. It is important that you flush this material from the sprayer before using it for the first time:

1.Fill material cup with water or compatible solvent, thread onto sprayer and hand tighten.

ti16712a

2.Put prime/pressure relief valve to UP position, then hold trigger in for 10 seconds.

ti16700a

3.Put prime/pressure relief valve DOWN to spray position.

ti16701a

4.Reverse spray tip to UNCLOG position and trigger sprayer into a waste area for 10 seconds.

ti14991a

ti16713a

Setup

5.Engage trigger lock and put prime/pressure relief valve UP to release pressure.

ti16699a

ti16700a

 

6.Unscrew and remove material cup.

7.Disengage trigger lock, put prime/pressure relief valve DOWN, hold sprayer slightly above material cup, and pull trigger to discharge fluid from pump.

ti16714a

8.Put prime/pressure relief valve UP and pull trigger to finish material flushing.

9.Discard material in cup.

12

3A1698F

Image 12
Contents Fine Finish Hand-Held Paint Sprayer 3A1698F Table of Contents Grounding Wire Repair Fire and Explosion Hazard Equipment Misuse Hazard Pressurized Aluminum Parts Hazard Component Identification Charging the Battery Charger Status Indicator LightsSprayer Status Indicator Trigger Lock Pressure Relief Procedure Prime/Pressure Relief Valve PositionSpray Tip Position Setting Hi/Lo Switch Adjusting Pressure Motor Speed Low Speed High SpeedSetup Flexible Suction TubeSpraying Ceilings, Walls and Crown Molding Spraying Floors and Base BoardsSprayer Setup Reversible Tip Selection Chart Starting a New Job Or Refilling the CupInstall Tip/Guard Assembly if not installed Getting Started with Basic TechniquesTriggering Sprayer Aiming SprayerUnclogging Spray Tip/Guard Assembly Shutdown and Cleaning Flushing SprayerTi15529ati16727a Cleaning Sprayer Exterior StorageFine Finish Tip Wear Replacement Parts and Kits Parts List Description 62-66 Model 16H240 16U241 Alternate Priming Method Inlet Valve Removal/Service InstallationOutlet Valve Repair RemovalTroubleshooting Problem Cause SolutionSpray Pattern Diagnostics Problem Cause Solution See Reversible Tip Selection ChartSpray pattern spits at Technical Data SprayerPreferred Material Settings Log 3A1698F Graco Standard Warranty Graco Information