Graco 16H245, 262612, 16H241, 16H243, 16H242, 16F887 16H240, 16H829 Ti15529ati16727a

Page 17

Shutdown and Cleaning

8.Disengage trigger lock, reverse tip to UNCLOG position, and pull trigger for 5 seconds to prime sprayer.

11.Engage trigger lock and put prime/pressure relief valve UP to release pressure.

ti16698a ti14991a

ti16699a

ti16700a

ti14999a

9.Put prime/pressure relief valve DOWN to spray position. Trigger sprayer into waste area until no paint appears in water or flushing fluid.

ti16701a

ti16713a

10. If sprayer is not completely clean, repeat steps 4-9.

To avoid serious injury or damage to equipment, do not expose the sprayer electronics to flushing solvents. Keep sprayer at least 10 in. above the rim of the con- tainer when flushing.

ti15529ati16727a

Keep spray area well-ventilated. Keep a good supply of fresh air moving through the area. When flushing with solvents, always ground the sprayer and waste container.

12.Remove material cup and discard used fluid.

13.Use a stiff wire such as a paper clip to make sure vent hole is open.

ti17102a

14.Remove Spray Tip/Guard Assembly and clean with water or flushing fluid. A soft brush can be used to loosen and remove dried material if needed.

ti15003a

ti15003a

NOTICE

The tip is permanently attached to the guard. Removing the tip from the guard will result in damage to the tip assembly.

Do not store tip/guard assembly or suction tube in sol- vent other than mineral spirits. Damage to parts may occur.

3A1698F

17

Image 17
Contents Fine Finish Hand-Held Paint Sprayer 3A1698F Table of Contents Grounding Wire Repair Fire and Explosion Hazard Equipment Misuse Hazard Pressurized Aluminum Parts Hazard Component Identification Sprayer Status Indicator Charging the BatteryCharger Status Indicator Lights Spray Tip Position Trigger Lock Pressure Relief ProcedurePrime/Pressure Relief Valve Position Low Speed High Speed Setting Hi/Lo Switch Adjusting Pressure Motor SpeedFlexible Suction Tube SetupSpraying Ceilings, Walls and Crown Molding Spraying Floors and Base BoardsSprayer Setup Starting a New Job Or Refilling the Cup Reversible Tip Selection ChartGetting Started with Basic Techniques Install Tip/Guard Assembly if not installedTriggering Sprayer Aiming SprayerUnclogging Spray Tip/Guard Assembly Flushing Sprayer Shutdown and CleaningTi15529ati16727a Fine Finish Tip Wear Cleaning Sprayer ExteriorStorage Replacement Parts and Kits Parts List Description 62-66 Model 16H240 16U241 Alternate Priming Method Installation Inlet Valve Removal/ServiceRemoval Outlet Valve RepairProblem Cause Solution TroubleshootingSee Reversible Tip Selection Chart Spray Pattern Diagnostics Problem Cause SolutionSpray pattern spits at Sprayer Technical DataPreferred Material Settings Log 3A1698F Graco Information Graco Standard Warranty