Graco 16H241, 262612, 16H243, 16H245, 16H242, 16F887 16H240 Unclogging Spray Tip/Guard Assembly

Page 15

Unclogging Spray Tip/Guard Assembly

Unclogging Spray Tip/Guard Assembly

Do not operate or spray near children. Do not aim the sprayer at, or spray any person or animal. Keep hands and other body parts away from the discharge. For example, do not try to stop leaks with any part of the body.

1.To unclog tip obstruction, engage trigger lock and put prime/pressure relief valve UP to release pres- sure.

ti16700a

ti16699a

2. Reverse spray tip to UNCLOG position.

ti14991a

3.Aim sprayer at waste area, disengage trigger lock, and put prime/pressure relief valve DOWN to spray position. Pull trigger to clear clog.

5.Disengage trigger lock, put prime/pressure relief valve DOWN to spray position, and resume spray- ing.

ti16698a ti16701a

6.If tip is still clogged, you may have to repeat steps 1 - 5 and rotate the tip from SPRAY to UNCLOG several times. Repeat step 1 to release pressure, remove and clean filter, or replace with new tip assembly.

ti14989a

NOTE: Filter assembly is reverse-threaded: Turn left (or counter-clockwise) to install. Turn right (or clockwise) to remove.

NOTICE

Make sure filter is completely screwed into the Tip/Guard Assembly to avoid damage to the filter. Do not use a damaged filter or poor sprayer performance may result.

7.When obstruction is cleared, engage trigger lock and rotate arrow-shaped handle back to SPRAY position.

ti16698ati16701a

ti16699a

ti16992a

 

4.Engage trigger lock. Put prime/pressure relief valve UP to release pressure and rotate spray tip back to SPRAY position.

ti16700a

ti16992a

3A1698F

15

Image 15
Contents Fine Finish Hand-Held Paint Sprayer 3A1698F Table of Contents Grounding Wire Repair Fire and Explosion Hazard Equipment Misuse Hazard Pressurized Aluminum Parts Hazard Component Identification Charging the Battery Charger Status Indicator LightsSprayer Status Indicator Trigger Lock Pressure Relief Procedure Prime/Pressure Relief Valve PositionSpray Tip Position Low Speed High Speed Setting Hi/Lo Switch Adjusting Pressure Motor SpeedSpraying Floors and Base Boards SetupFlexible Suction Tube Spraying Ceilings, Walls and Crown MoldingSprayer Setup Starting a New Job Or Refilling the Cup Reversible Tip Selection ChartAiming Sprayer Install Tip/Guard Assembly if not installedGetting Started with Basic Techniques Triggering SprayerUnclogging Spray Tip/Guard Assembly Flushing Sprayer Shutdown and CleaningTi15529ati16727a Cleaning Sprayer Exterior StorageFine Finish Tip Wear Replacement Parts and Kits Parts List Description 62-66 Model 16H240 16U241 Alternate Priming Method Installation Inlet Valve Removal/ServiceRemoval Outlet Valve RepairProblem Cause Solution TroubleshootingSee Reversible Tip Selection Chart Spray Pattern Diagnostics Problem Cause SolutionSpray pattern spits at Sprayer Technical DataPreferred Material Settings Log 3A1698F Graco Information Graco Standard Warranty