1.Prime the sprayer with paint.

a.Close the pressure drain valve. See Fig 10±2.

b.Don't install the spray tip yet!

c.Put the suction tube into the paint container. You can hang the pail on the pail hanger. See Fig 10±2.

d.Turn the pressure adjusting knob all the way counterclockwise to lower the pressure.

e.Disengage the trigger safety latch. See the detail in Fig 10±2.

f.Hold a metal part of the gun firmly against a grounded metal waste container. See Fig 10±1. Hold the trigger open, turn the sprayer ON, and slowly increase the pressure until the sprayer starts. Keep the gun triggered until all air is forced out of the system and the paint flows freely from the gun. Release the trigger and engage the trig- ger safety latch.

NOTE: If the pump is hard to prime, open the pressure drain valve. When fluid comes through the drain tube, close the drain valve. Disengage the trigger safety latch and repeat Step 1.f.

g.Check all fluid connections for leaks; relieve pres- sure before tightening connections.

GROUND

WIRE

MAINTAIN FIRM

METAL-TO-METAL

CONTACT BETWEEN

GUN AND GROUNDED

METAL CONTAINER

Fig 10±1

0664

 

2.Install the spray tip and tip guard.

a.Be sure the trigger safety latch is engaged.

b.Install the spray tip. If using the RAC IV, refer to manual 307±848, supplied with the gun, for in- stallation instructions.

PACKING NUT/WETCUP

PAIL HANGER

DRAIN TUBE

SUCTION TUBE

ON/OFF SWITCH

PRESSURE ADJUSTING KNOB

PRESSURE DRAIN VALVE

DETAIL

TIP GUARD

SPRAY TIP

TRIGGER SAFETY LATCH SHOWN ENGAGED (ON SAFE)

10307-724

Image 10
Contents Model 231±018 Model 231±001, Series BModel 231±390 Model 220±726, Series CSpray Tip Safety General SafetySpray Gun Safety Devices Medical Alert±±Airless Spray WoundsFluid and Solvent Compatibility Flushing SafetySystem Pressure Hose Grounding ContinuityDispositifs de sécurité du pistolet Consignes générales de sécuritéSoins médicaux Consignes de sécurité concernant lajutage du pulvérisateurMise à la terre ou à la masse PressionCompatibilité chimique des corps Continuité de la mise à la terre des tuyauxTratamiento médico EL Rociado a Alta Presion Puede Causar Graves LesionesSeguridad general Aparatos de seguridad de la pistola pulverizadoraPuesta a tierra Presión del sistemaCompatibilidad de fluido Continuidad del circuito de puesta a tierra de la mangueraConnect the hose and gun. See ±1 SetupCheck the electrical service Plug in the sprayerPressure Relief Procedure OperationInstall the spray tip and tip guard Prime the sprayer with paintAdjust the spray pattern Cleaning a Clogged TipShutdown and Care When to Flush Startup after storageHOW to Flush Application Methods Right WrongPressure Relief Procedure Troubleshooting GuideProblem Cause Solution Fluid supply often to prevent running the pump Reinstalling the Pump. See ±1 Displacement PumpReassembly Notes Removing the Pump. See ±1206 Reassembly Procedure204 222Replacing the Connecting ROD and Bearing Replacing the Drive Assembly 55d 55a303 Replacing the Electric Motor & CapacitorCapacitor 23fCircuit Board Removal Replacing the Pressure Control & Circuit BoardPressure Control Removal Service Tools Needed Pressure Control AdjustmentFollow the Pressure Relief Procedure Warning, above 0750 Parts Drawing & List ± Pressure Control Circuit Board ApplicationsModel 218±215, Series C Carbon Steel Displacement Pump Displacement Pump Parts Drawing & ListDescription Qty Parts List ± Sprayer with Upright Cart Model 231±001, Series B, Basic SprayerParts Drawing ± Sprayer with Upright Cart Model 231±001, Series BParts List ± Sprayer with LO-BOY Cart Model 220±726, Series C, Basic SprayerModel 220±726, Series C Parts Drawing ± Sprayer with LO-BOY CartDetail a Model 231±018 Complete Upright Sprayer with Contractor Gun Parts Drawing & List ± Complete SprayersModel 231±390 Complete Upright Sprayer with Flex Gun Model 231±051 Complete Lo±Boy Sprayer with Flex GunAccessories Manual Change SummaryImportant Phone Numbers Technical DataDimensions To you 1±800±328±0211 Toll Free307-724 Table of Contents Graco Warranty and DisclaimersMINNEAPOLIS, MN 55440±1441 Model 231±390 shownGraco INC. P.O. BOX Upright LoBoyInjection Hazard Packing Repair Kit 222±587