Graco Inc EM390 instruction manual 0750

Page 25

PRESSURE CONTROL ADJUSTMENT

NOTE: See Fig 25±1 for the following procedure.

4.Open the needle valve slightly. Turn the pressure con- trol knob (A) to the minimum setting.

5.Plug in the sprayer and turn the switch ON. Increase the pressure setting just enough to start the sprayer. Prime the hose, being sure to eliminate all air from the system.

6.Open the needle valve a little more±±enough to allow the pump to run continuously±±and turn the pressure control knob to maximum. Now, very slowly start to close the needle valve, but don't close it all the way. Observe the pressure at which the pump stalls, which should be approximately 2500 psi (172 bar).

NOTE: The slower the pressure is raised, the easier it is to note the exact stall pressure. Closing the needle valve quickly causes the pressure to rise

8.Open the needle valve very slowly while observing the pressure gauge. Check to see if the pressure drops to approximately 2100 psi (147 bar) before starting again.

If the pressure is not 2100 psi (147bar):

Shut off and unplug the sprayer, but do not relieve pressure. Turn the differential wheel (D) just one notch and repeat Steps 5 and 6. Check the pressure drop again, and repeat if necessary.

NOTE: If you adjust the differential wheel, recheck the stall pressure (steps 5 and 6) to be sure the stall pressure has not changed.

9.Follow the Pressure Relief Procedure Warning on page 24. Flush the water out with mineral spirits. Re- lieve pressure again. Install the plug (121) and the pressure control cover (41). Remove the test hose, needle valve and pressure gauge.

ON/OFF SWITCH

too fast which gives a false reading.

If the pressure is lower than 2500 psi (172 bar):

Unplug the sprayer. Relieve pressure. Insert the wrench and untighten the pressure adjustment nut 1/8 turn or less, then repeat steps 5 and 6.

If the pressure is higher than 2500 psi (172 bar): Unplug the sprayer. Relieve pressure. Insert the wrench and tighten the pressure adjustment nut 1/8 turn or less and repeat steps 5 and 6. Repeat this pro- cedure until the proper stall pressure is obtained.

D

A

B

7.Now check to see at what pressure the sprayer starts to run again after it stalls. Plug in the sprayer, turn it on, close the needle valve, and set the pressure at maximum. Allow the sprayer to run until it stalls.

C

TIGHTEN

Fig 25±1

0750

307-724 25

Image 25
Contents Model 231±390 Model 231±001, Series BModel 231±018 Model 220±726, Series CSpray Gun Safety Devices General SafetySpray Tip Safety Medical Alert±±Airless Spray WoundsSystem Pressure Flushing SafetyFluid and Solvent Compatibility Hose Grounding ContinuitySoins médicaux Consignes générales de sécuritéDispositifs de sécurité du pistolet Consignes de sécurité concernant lajutage du pulvérisateurCompatibilité chimique des corps PressionMise à la terre ou à la masse Continuité de la mise à la terre des tuyauxSeguridad general EL Rociado a Alta Presion Puede Causar Graves LesionesTratamiento médico Aparatos de seguridad de la pistola pulverizadoraCompatibilidad de fluido Presión del sistemaPuesta a tierra Continuidad del circuito de puesta a tierra de la mangueraCheck the electrical service SetupConnect the hose and gun. See ±1 Plug in the sprayerOperation Pressure Relief ProcedurePrime the sprayer with paint Install the spray tip and tip guardCleaning a Clogged Tip Adjust the spray patternShutdown and Care Startup after storage When to FlushHOW to Flush Right Wrong Application MethodsPressure Relief Procedure Troubleshooting GuideProblem Cause Solution Fluid supply often to prevent running the pump Reassembly Notes Displacement PumpReinstalling the Pump. See ±1 Removing the Pump. See ±1204 Reassembly Procedure206 222Replacing the Connecting ROD and Bearing 55d 55a Replacing the Drive AssemblyCapacitor Replacing the Electric Motor & Capacitor303 23fCircuit Board Removal Replacing the Pressure Control & Circuit BoardPressure Control Removal Service Tools Needed Pressure Control AdjustmentFollow the Pressure Relief Procedure Warning, above 0750 Circuit Board Applications Parts Drawing & List ± Pressure ControlModel 218±215, Series C Carbon Steel Displacement Pump Displacement Pump Parts Drawing & ListDescription Qty Model 231±001, Series B, Basic Sprayer Parts List ± Sprayer with Upright CartModel 231±001, Series B Parts Drawing ± Sprayer with Upright CartModel 220±726, Series C, Basic Sprayer Parts List ± Sprayer with LO-BOY CartModel 220±726, Series C Parts Drawing ± Sprayer with LO-BOY CartDetail a Model 231±390 Complete Upright Sprayer with Flex Gun Parts Drawing & List ± Complete SprayersModel 231±018 Complete Upright Sprayer with Contractor Gun Model 231±051 Complete Lo±Boy Sprayer with Flex GunManual Change Summary AccessoriesDimensions Technical DataImportant Phone Numbers To you 1±800±328±0211 Toll Free307-724 Graco Warranty and Disclaimers Table of ContentsGraco INC. P.O. BOX Model 231±390 shownMINNEAPOLIS, MN 55440±1441 Upright LoBoyPacking Repair Kit 222±587 Injection Hazard