WHEN TO FLUSH

NOTE: The Pressure Relief Procedure Warning is on page 16.

CAUTION

NEVER leave water or water±base paint in the sprayer if there is the slightest change it could freeze. Flush out the water or water±base paint with mineral spirits. If water freezes in the pressure con- trol tube, it prevents the sprayer from being started, and causes serious damage to the pressure control.

1.New Sprayer. The sprayer was factory tested in lightweight oil, which was left in to protect the pump parts.

Before using water-base paint, flush with mineral spirits, followed by a soapy water flush, and then a clean water flush.

Before using oil-base paint, flush with mineral spirits, only.

2.Changing Colors. Flush with a compatible solvent such as mineral spirits or water.

3.Changing from water-base to oil-base paint. Flush with warm, soapy water, then mineral spirits.

4.Changing from oil-base to water-base paint. Flush with mineral spirits, followed by warm, soapy water, and then a clean water flush.

5.Storage.

Water-base paint: Flush with water, and then mineral spirits. Leave the pump, hose and gun filled with mineral spirits. Shut off the sprayer and open the pressure drain valve to relieve pressure.

Oil-base paint: Flush with mineral spirits. Shut off and unplug the sprayer, open the pressure drain valve to relieve pressure.

6.Startup after storage.

Before using water-base paint, flush out the min- eral spirits with soapy water, and then with clean water.

When using oil-based paint, flush out the mineral spirits with the paint to be sprayed.

NOTE: HOW TO FLUSH is on page 14.

307-724 13

Image 13
Contents Model 231±390 Model 231±001, Series BModel 231±018 Model 220±726, Series CSpray Gun Safety Devices General SafetySpray Tip Safety Medical Alert±±Airless Spray WoundsSystem Pressure Flushing SafetyFluid and Solvent Compatibility Hose Grounding ContinuitySoins médicaux Consignes générales de sécuritéDispositifs de sécurité du pistolet Consignes de sécurité concernant lajutage du pulvérisateurCompatibilité chimique des corps PressionMise à la terre ou à la masse Continuité de la mise à la terre des tuyauxSeguridad general EL Rociado a Alta Presion Puede Causar Graves LesionesTratamiento médico Aparatos de seguridad de la pistola pulverizadoraCompatibilidad de fluido Presión del sistemaPuesta a tierra Continuidad del circuito de puesta a tierra de la mangueraCheck the electrical service SetupConnect the hose and gun. See ±1 Plug in the sprayerOperation Pressure Relief ProcedurePrime the sprayer with paint Install the spray tip and tip guardCleaning a Clogged Tip Adjust the spray patternShutdown and Care Startup after storage When to FlushHOW to Flush Right Wrong Application MethodsPressure Relief Procedure Troubleshooting GuideProblem Cause Solution Fluid supply often to prevent running the pump Reassembly Notes Displacement PumpReinstalling the Pump. See ±1 Removing the Pump. See ±1204 Reassembly Procedure206 222Replacing the Connecting ROD and Bearing 55d 55a Replacing the Drive AssemblyCapacitor Replacing the Electric Motor & Capacitor303 23fCircuit Board Removal Replacing the Pressure Control & Circuit BoardPressure Control Removal Service Tools Needed Pressure Control AdjustmentFollow the Pressure Relief Procedure Warning, above 0750 Circuit Board Applications Parts Drawing & List ± Pressure ControlModel 218±215, Series C Carbon Steel Displacement Pump Displacement Pump Parts Drawing & ListDescription Qty Model 231±001, Series B, Basic Sprayer Parts List ± Sprayer with Upright CartModel 231±001, Series B Parts Drawing ± Sprayer with Upright CartModel 220±726, Series C, Basic Sprayer Parts List ± Sprayer with LO-BOY CartModel 220±726, Series C Parts Drawing ± Sprayer with LO-BOY CartDetail a Model 231±390 Complete Upright Sprayer with Flex Gun Parts Drawing & List ± Complete SprayersModel 231±018 Complete Upright Sprayer with Contractor Gun Model 231±051 Complete Lo±Boy Sprayer with Flex GunManual Change Summary AccessoriesDimensions Technical DataImportant Phone Numbers To you 1±800±328±0211 Toll Free307-724 Graco Warranty and Disclaimers Table of ContentsGraco INC. P.O. BOX Model 231±390 shownMINNEAPOLIS, MN 55440±1441 Upright LoBoyPacking Repair Kit 222±587 Injection Hazard