Wetting Hose

Wetting Hose

Wet inside of hose before each use to flush out sedi- ment and prevent texture material from packing out hose.

1.Pour one (1) gallon (3.8 liters) of clean water into hopper.

2. Close gun air valve (23).

23

closed

ti4005

3.Turn air inlet valve (E) open. Aim gun into hopper

(G) and trigger gun to circulate water for a few min- utes to wet inside of material hose.

4.Trigger gun into waste pail until hopper no longer contains water.

ti4290a

WASTE

5. Open gun air valve (23) to relieve compressor air.

23

TI

313384B

9

Image 9
Contents Repair Related ManualsFire and Explosion Hazard 313384B Component Identification Component Identification List Pressure Relief Procedure Setup Removing and Installing HopperPreparation Additional Equipment Needed Installing Hopper GWetting Hose Waste Wetting SystemWater Mixing MaterialOperation Characteristics Application Nozzle Orifice† Nozzle Number Air Volume‡ Spray TechniquesNozzle Selection System Adjustment Air Flow Adjustment Material Flow AdjustmentPreventing Material Surge at Gun Trigger For Continuous SprayingShutdown and Cleanup After SprayingRelieve Pressure , Maintenance Technical DataComponent Task Frequency Graco Information Graco Standard Warranty