Graco Inc 2000EX, 313384B, 257030 Maintenance, Technical Data, Component Task Frequency

Page 17

Maintenance

Maintenance

Component

Task

Frequency

 

 

 

 

 

 

Hoses

Check for wear and/or damage

Daily

 

 

Drain system of all water

After each use

 

 

 

 

Air and Material Hose Connections

Add a few drops of light oil

After each use

 

 

 

 

 

Remove hose from pump air line and

 

Lubricate

add 2 drops of machine oil to air inlet

 

after every 500 hours of operation (or

 

 

 

 

monthly)

 

 

 

Diaphragm Pump

Flush

Before storing

 

 

Before each use, check to make sure

 

Thread connections

all connections are light and leak-free

 

 

 

Torque all threaded connections

 

 

 

 

every two months

 

 

 

 

Clean

After each use

Gun

 

 

Add a few drops of light oil to flow

After each use

 

adjustment

 

 

 

 

 

Technical Data

Maximum working air pressure Maximum working fluid pressure Compressor (not supplied by Graco) Air Delivery

Hopper capacity

Maximum delivery with texture material Dimensions

Length

Width

Height

Sound

Weight

With hoses and gun

Wetted Parts

120 psi (8.27 bar)

120 psi (8.27 bar) Oil-less compressor 12 CFM @ 100 psi minimum (340 lpm @ 6.9 bar)

17 US gallons (64 liters)

4.0 gpm (15.14 lpm)

38 in. (965 mm) with handles

24 in. (610 mm)

40 in. (1016 mm) Reference Pump Manual 308479

110 lb (49.9 kg)

PVC, zinc plate CS, Buna-N, aluminum, brass, polyethylene, SST, UHMW, Delrin

313384B

17

Image 17
Contents Repair Related ManualsFire and Explosion Hazard 313384B Component Identification Component Identification List Pressure Relief Procedure Preparation SetupRemoving and Installing Hopper Additional Equipment Needed Installing Hopper GWetting Hose Waste Wetting SystemWater Mixing MaterialOperation Characteristics Nozzle Selection Application Nozzle Orifice† Nozzle Number Air Volume‡Spray Techniques System Adjustment Air Flow Adjustment Material Flow AdjustmentPreventing Material Surge at Gun Trigger For Continuous SprayingRelieve Pressure , Shutdown and CleanupAfter Spraying Component Task Frequency MaintenanceTechnical Data Graco Information Graco Standard Warranty