Troubleshooting
Electrical Troubleshooting with SVR
NOTE: Additional gun troubleshooting can be done using the Remote Spraying Voltage Readout (SVRt). See Accessories to order the SVR and the RF transmitting power supply.
Problem
Cause
Solution
Lower than normal voltage output
Insufficient air pressure to the turbine alternator.
Increase the air pressure to the gun.
Faulty turbine alternator. | Replace the turbine alternator. See page 28. |
|
|
Improper distance between gun and | Adjust the spraying distance to |
workpiece. | |
|
|
Fluid resistivity is too low. | Check the fluid resistivity with a paint meter |
| and probe. |
|
|
Dirty gun.
Clean the gun. See page 14.
Higher than normal voltage out- | Faulty gun resistance. | Check the gun resistance. See page 20. |
put |
|
|
| Fluid resistivity higher than normal. | Check the fluid resistivity with a paint meter |
|
| and probe. |