Graco Inc PRO 4500sc manual Air Trigger Valve Repair, Atomizing Air Valve Removal and Replacement

Page 31

Service

Air Trigger Valve Repair

1.Prepare the gun for service as instructed on page 22.

2.Using a 14 mm socket wrench, remove the fluid adjustment assembly (45), o-ring (23) and spring (44). See Fig. 21.

CAUTION

Clean all parts in non-conductive solvent compatible with the fluid being used, such as xylol or mineral spirits. Use of conductive solvents can cause the gun to malfunction.

3.Loosen the air valve packing nut (40) one full turn. Remove the air valve shaft (39) with a pliers.

CAUTION

When removing the air valve shaft (39) be careful not to damage the seat area.

4.Check the o-rings (41, 23) for damage and replace if necessary. Apply petroleum jelly to the o-rings.

CAUTION

Do not over-lubricate parts. Excessive lubricant on the o-ring (41) and air valve shaft (39) can be pushed into the gun air passage and blemish the finish on the workpiece.

5.

Unscrew the packing nut (40) to check the u-cup

 

(42). Do not remove the u-cup unless it is dam-

 

aged.

6.

Install the air valve shaft (39), with the o-ring (41),

 

and spring (44), into the back of the gun handle

 

(7). If the u-cup (42) was removed, install the air

 

valve shaft (39) before installing the u-cup. Install

 

the u-cup with its lips facing into the gun handle.

7.

Install the fluid adjustment assembly (45), with the

 

o-ring (23). Tighten the adjustment knob (45c) with

 

the 14 mm socket wrench. Tighten the air valve

Atomizing Air Valve Removal and Replacement

1.Prepare the gun for service as instructed on page 22.

2.Remove the fan air valve (43). See Fig. 22.

CAUTION

To avoid damaging the atomizing air valve (31), the fan air valve (43) must be removed before removing the atomizing air valve.

3.Remove the atomizing air valve (31) from the gun handle. Inspect the o-ring (19) and replace if necessary.

4.Install a new atomizing air valve (31).

5.Apply low strength (purple) Loctite or equivalent thread sealant to the fan air valve (43) housing threads. Start the valve housing threads into the handle by turning the fan air valve knob. Once the threads are started, rotate the knob (43c) fully counterclockwise. Torque the valve housing (43d) to 10–12 in-lb (1.1–1.4 NSm).

31

19

43 

Apply low strength (purple) Loctite or equivalent to fan air valve housing threads; Torque to 10–12 in-lb (1.1–1.4 N.m)

packing nut (40) until it bottoms.

Fig. 22

0386A

308131 31

Image 31
Contents Read and Keep for Reference 308131Part No , Series B Air Spray Gun with two-finger trigger Part No , Series B Air Spray Gun with four-finger trigger308131 Symbols Table of ContentsFIRE, EXPLOSION, and Electric Shock Hazard Pressurized Equipment Hazard KEY InstallationNon-Hazardous Area Hazardous AreaVentilate the Spray Booth Installing the SystemConnect the Air Line Refer to Fig Ground the System Connect the Exhaust TubeFIRE, EXPLOSION, Electric Shock Hazard Check the Electrical Grounding See Fig Page Filter the Fluid Pressure Relief ProcedureOperating Checklist OperationOperating the Spray Gun Selecting a Fluid Nozzle and Air CapComponent Rupture Hazard Fine Adjustments of the Spray Gun Atomizing Air Valve AdjustmentFIRE, EXPLOSION, and Electric Shock Hazard MaintenanceDaily Care and Cleaning ShutdownEquipment needed Clean the Air Cap and Fluid NozzleProcedure Flush the Spray GunSpray Pattern Troubleshooting TroubleshootingProblem Cause Solution Gun Operation Troubleshooting See Check the Electrical Grounding Electrical TroubleshootingElectrical Troubleshooting with SVR Test Gun Resistance See Fig Electrical TestsTest Resistor Stud Resistance See Fig Test Power Supply Resistance See FigPrepare the Gun for Service ServiceAir Cap/Nozzle/Resistor Stud Replacement Electrode Needle Replacement Barrel Removal Fluid Packing Removal Fluid Packing Rod Repair Power Supply Adjustment Power Supply Removal and ReplacementBarrel Installation Turbine Alternator Removal ReplacementDetail Fan Air Adjustment Valve Repair45c 45a  45b  45d  41 45e Fluid Adjustment Assembly RepairAir Trigger Valve Repair Atomizing Air Valve Removal and ReplacementMoving Parts Hazard ES ON-OFF Valve Repair308131 Detail a PartsElectrostatic Air Spray Gun, with four-finger trigger Part No , Series BAir Shutoff Valve AccessoriesConductive Air Supply Hose black Extended Air FittingMegohmmeter Grounding Clamp and WireSafety Warning Signs Fluid Hose Assemblies NylonGun System GUN SystemsFCC ID JHI1 Technical DataManual Change Summary Category DataGraco Phone Number Graco Standard WarrantyToll Free