TIP SIZE

FOR APPLICATION OF

.021

Exterior Latex on large unobstructed areas.(max. size allowed) ( 60 OZ. )

.018

Interior Latex, Exterior Latex, Shake Paint, Exterior Flat Paints. ( 46 OZ. )

.015

Alkyd Flat Enamel, Interior Latex, Semi-Gloss Enamel, Stains. ( 30 OZ. )

.013

Fine ground Gloss Enamels, and good quality Stains. ( 23 OZ. )

.011

Clear Varnishes and Lacquers. ( 15 OZ. )

.009

Clear Varnishes and Lacquers. ( 10 OZ. )

NOT: The above volumes achieved with gun wide open for 1 minute and pump spraying at 2000psi. All volumes are approximate. To test worn tips, spray water through the tip at 2000 psi. for 1 minute. Spray into bucket and weigh amount (less weight of bucket). If it is substantially greater than what is listed above, then the tip should be discarded or reclassified. As a tip wears, the hole gets larger and the fan pattern becomes narrower.

ORIFICE SIZE

All tips are rated by the size of the orifice or bore size. The bore size is measured in thousandths of an inch ( .018 = 18 thousandths of an inch ). The size of tip required is based on the consistency of the material to be sprayed. The thicker the paint, the larger the tip size required. Always consult the product label or ask the paint retailer for the manufacturer's recommendations with regard to proper tip sizes.

FAN WIDTH

Fan width or pattern width is determined by the spray tip's "fan width" classification. This size is measured in inches, and is determined when spraying 12 inches from the spray surface. Various methods of noting the fan widths are used by tip manufacturers. Ask your distributor for assistance.

NOTE: Two tips having the same tip size, but different fan widths will deliver the same amount of paint over a different area (wider or narrower strip). A spray tip with a narrow pattern width makes it easy to spray in tight places. Use only good quality, high-pressure tungsten carbide spray tips.

SPRAY TIP REPLACEMENT

During use, especially with Latex paint, high pressure and material abrasion will cause the orifice to grow larger. As the orifice grows larger, the fan width grows smaller. Replace tips before they become excessively worn. Worn tips waste paint, cause overspray, make cutting in difficult, and decrease sprayer performance. NOTE: When using Latex paint, a spray tip will wear at the rate of one size for approximately every 100

gallons of material sprayed.

An excessively worn tip can be the cause of apparent operating problems with the unit. If a tip is worn past the aperture size which the unit can support, pulsation will become evident in the spray fan/pattern. Added strain is placed on the Hydrapulse membrane as it attempts to keep the spray pressure consistent. When the tip wears beyond .031, its is releasing more material than the unit is bringing in. The natural reserve of product in the paint chamber is reduced and harm to the membrane begins. ALWAYS check your tips for wear when trouble shooting the equipment. The 1150GSD can support up to a maximum of a one .031 tip or two .021 tips.

TROUBLESHOOTING

Hydraulic Energy Regulated Output (H.E.R.O.) is more than just our name, it is the bases for the operation of the pump. It is the regulation or control, of hydraulic energy, which allows the equipment to

H.E.R.O. INDUSTRIES

12

1150GSD MANUAL - “B” VERSION

Image 13
Contents Version Beginning AT Serial Number Airless Spray EquipmentR.O. Warranty Table of Contents Important Safety PrecautionsAlways Always R.O. Airless Spray PaintingInstructions Setting UP to SprayHydrapulse B Version Beginning AT Serial Number E R a T I N GAlways Paint Straining Special Notes and Instructions Flushing the Unit AT Shutdown Or Color ChangeAirless Spray Painting GAS EngineAirless Spray Painting Suggestions and Technique Suggestions and TechniqueSpray TIP Selection Spray TIP Replacement TroubleshootingTIP Size For Application Orifice SizeR.O. Industries 1150GSD Manual B Version Hydraulic Intake Valve REF# 66 Paint Intake Valve Assembly REF#Hydraulic Outgo Valve REF# 74, PART# 4-27C Prime Valve REF# 36, PART# Paint Outgo Valve REF# 26, PART# 4-611CSituation Gasoline Engine Wont START/RUN No PRESSURE, Blue Hydraulic Fluid in Paint Troubleshooting Sprayer does not Prime with Paint Spray Pattern is Spotty or Uneven Hydrapulse Membrane ReplacementRemoval Replacement of Intake SeatTools Required Piston RepairsSpecial Notes Outgo Valve REF# Prime Valve Repairs O L S Required Pressure Control ValveO L S Accessories Parts ListZIP TIP INSERT, Available in the Following Sizes Parts ListAssy Description QTYKIT Outgo Parts Industries 1150GSD Manual B Version Drive Parts Decals 1150GSD Parts Schematic Manual B Version