Alcatel Carrier Internetworking Solutions ACT 250 user manual Lev, Lng, Nsp, Syntax Result

Page 20

Commissioning

Detailed description of RS commands

January 2001

LEV

Syntax

Result

LNG

Syntax

Result

See also: SHT

NSP

Syntax

Result

See also: RPM, SBY

Returns the state of the parameters defined by SET

#adrLEV<CR>[<LF>]

#adr,nnnnn,sssss,aaaa,hhhhh or

#adr,nnnnn rpm,sssss rpm,aaaa mA,hhhhh hours

Returns the current values:

nnnnn: speed set point sssss : stand-by speed aaaa : max. current set point

hhhhh : alert level for pump bearing maintenance

Returns the strings sent with the identification sub-strings

#adrLNG<CR>[<LF>]

#adr,ok

AVT>

Allows the parameters returned by the DLR, LEV and SPD commands to be identified with sub-strings. DLR, LEV, SPD.

Also generates the “AVT>” prompt each time a <CR> character is received.

Switches the speed set point to the nominal speed value

#adrNSP<CR>[<LF>]

#adr,ok

The speed set point for the pump is set to its nominal value. This configuration is automatically saved in user memory.

This mode of operation prevents the use of the “RPM” command.

Alcatel Vacuum Technology France - ACT 250 addendum

19

Image 20
Contents ACT Contents Syntax conventions applicable to all commands UsePresentation ACT 250 controllerEurope 108936 108948 Accessories108935 Local control mode Remote controlThere are three possible remote control modes ACT 250 box controller control modesACT 250 OEM controller control modes ACT 250 controller technical characteristics ACT 250 box dimensions in mmACT 250 OEM dimensions in mm Safety instructions CommissioningACT 250 controller electrical connections ACT 250 remote connector characteristics Voltage control modeExt. safety Select Mode Principle of voltage- controlled optocoupled inputsSignalling on output contacts ACT 250 remote connector wiring Use in remote control modeWiring the RS 232 or RS 485 serial link RS 232 / 485 serial linkParity Baud rate 9600 4800Result #aaa,ok or Err2 Detailed description of RS commandsSyntax conventions applicable to all commands #adrCKSOFFCRLF Result #adr,ok,S For CksonEnables DataLogger operation RS232 only Result #adr,ok or Err2IDN #adrECHOFFCRLFIdentifies the device which is communicating, and its Software versionLEV LNGNSP Syntax ResultOPT RPMSAV Syntax Result See also SELResult #adr,ok or #adr,ErrX If error SELDefines the character which separates the parameters A reply Syntax #adrSEPnnnCRLFSET SHTSPD Syntax Result See also LEVTMP Defines the turbomolecular pump operating stateUse Controlling the pump from the ACT 250 controllerStarting the pump with the Start switch Indication of rotation during operation controller on Precautions Local mode operationController functions Use France GermanyItaly Japan