Alcatel Carrier Internetworking Solutions ACT 250 user manual Controller functions

Page 27

Use

Controller functions

Precautions

Local mode operation

The “OEM” version of the ACT 250 has been designed with electrical safety and electromagnetic compatibility standards in mind.

It is the user’s responsibility to provide external shielding to comply with EMC and electrical safety standards.

The Start and Stop functions use switches located on the front panel of the “box” version and on the board for the “OEM” version.

POWER

FAULT

SPEED

START

STOP

 

 

 

 

 

The pump’s operating status is shown by the state of the “POWER” indicator (yellow) and the three “FAULT” (red) and “SPEED” (yellow and green) indicators.

Indication of rotation during operation (controller on)

1

Before start-up

 

 

 

 

2

During start-up

 

 

 

 

3

Pump at nominal speed

 

 

 

4

Alert or fault

Alert

 

triggered

 

 

(see page 27 )

Fault

 

 

5

Overload

 

 

 

6 Speed set point lowered

7

Pumping stopped

Press button

START STOP

0

 

0

 

 

 

1 0

0

 

0

 

 

 

0 0

0

 

0

 

 

 

00

0 1

Pump

motor on

NO

YES

YES

YES

NO

YES

YES

NO

Pump

State of indicators

 

 

 

rotation

Power

Fault

Speed

speed

Yellow

Red

Yellow Green

 

0

 

 

 

< selected

 

 

 

speed

 

 

 

= selected

speed

selected

speed

0

< selected

speed

> selected

speed

0

January 2001

indicator off

indicator on

indicator flashing

26

Alcatel Vacuum Technology France - ACT 250 addendum

Image 27 Contents
ACT Contents Use Syntax conventions applicable to all commandsACT 250 controller PresentationAccessories 108935Europe 108936 108948 ACT 250 box controller control modes Local control modeRemote control There are three possible remote control modesACT 250 OEM controller control modes ACT 250 box dimensions in mm ACT 250 controller technical characteristicsACT 250 OEM dimensions in mm Commissioning Safety instructionsACT 250 controller electrical connections Principle of voltage- controlled optocoupled inputs ACT 250 remote connector characteristicsVoltage control mode Ext. safety Select ModeSignalling on output contacts Use in remote control mode ACT 250 remote connector wiringBaud rate 9600 4800 Wiring the RS 232 or RS 485 serial linkRS 232 / 485 serial link ParityDetailed description of RS commands Syntax conventions applicable to all commandsResult #aaa,ok or Err2 Result #adr,ok,S For Ckson #adrCKSOFFCRLFResult #adr,ok or Err2 Enables DataLogger operation RS232 onlySoftware version IDN#adrECHOFFCRLF Identifies the device which is communicating, and itsSyntax Result LEVLNG NSPSyntax Result See also SEL OPTRPM SAVA reply Syntax #adrSEPnnnCRLF Result #adr,ok or #adr,ErrX If errorSEL Defines the character which separates the parametersSyntax Result See also LEV SETSHT SPDDefines the turbomolecular pump operating state TMPControlling the pump from the ACT 250 controller UseStarting the pump with the Start switch Precautions Local mode operation Controller functionsIndication of rotation during operation controller on Use Japan FranceGermany Italy