Sanyo CVW-EXA124, CVW-EXA284, CVW-EXA184, CVW-EXA224 service manual Installing Handrail and Bumper

Page 15

3.10Installing Handrail and Bumper

Attaching the Bumper

1.Attach Maintenance Bumper (length 39-3/8 inches) to Bumper Brackets over the electrical connection box (“Raceway”) on each SANYO Case. The Raceway is located on the right end of each SANYO Case.

2.Attach Full-Length Bumpers between Maintenance Bumpers on separate SANYO Cases, and also between Maintenance Bumpers and Patch Ends.

3.Cut Full-Length Bumpers to size on-site. Cut to correct size so that no gaps remain between pieces.

Attaching the Handrail

1.Starting at one end of SANYO Case line-up, attach pieces of Handrail to Handrail Retainer, butting the pieces end-to-end without gaps.

2.When you reach the final piece of Handrail to be installed between the last SANYO Case in the line-up and the Patch End, cut that piece to length so there are no gaps between Handrails or between Handrails and Patch Ends.

3.Cut Handrail to size on-site. Cut to correct size so that no gaps remain between pieces.

WARNING!

Wear appropriate eye and hand protection and exercise care when using powered tools to prevent personal injuries and damage to the case.

15

Image 15
Contents 80 7/8, L 96 3/8 / H 80 7/8, L 144 5/8 MULTI-DECK Fresh Produce CasesActivity Safety Precautions Table of Contents Care and Cleaning Guidelines CVW-EXA284 CVW-EXA224 SpecificationsCVW-EXA184 CVW-EXA124 External Dimensions Footprint DimensionsCVW-EXA184 / CVW-EXA124 Location Unloading and Carpentry ProceduresUnloading Instructions & Precautions NSF CertificationCase Leveling Aligning Cases Perimeter gasket is required by NSF Joining InstructionsConnecting cases Installing Patch Ends CVW-EXA284/224CVW-EXA184/124 Installing Kickplate Installing Handrail and Bumper Piping Plumbing, Refrigeration Refrigeration, Plumbing & Electrical ProceduresElectrical Data Electrical Guidelines & PrecautionsWiring Wiring Color CodeWiring Diagram Load Limits OperationMagnet Installing FDA/NSF ThermometerCare and Cleaning Guidelines Exterior Panels Daily CleaningMirrors, Fluorescent Lamps, Drain Trap Monthly Cleaning Honeycomb Assemblies at least every 3 months Service Replacing Fan Motors and BladesTo replace the fan motors For models with Standard-type AC Fan Motors For models with high-efficiency-type DC fan motors To replace electronic ballasts Replacing Electronic BallastsLamp Cover END CAP Replacing Fluorescent LampsSporlan Expansion Valve DanfossPage Sanyo E & E Corporation