Sanyo CVW-EXA224, CVW-EXA284 service manual CVW-EXA184 CVW-EXA124

Page 6

1.2CVW-EXA184 (H: 80 7/8”, L: 96 3/8”) / CVW-EXA124 (H: 80 7/8”, L: 144 5/8”)

Model Name

 

CVW-EXA184

 

 

 

CVW-EXA124

General

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Application:

 

Medium Temperature (Fresh Produce)

Medium Temperature (Fresh produce)

Cooling Capacity:

1146 BTU/h/ft.

2682W

1146 BTU/h/ft.

4195W

Discharge Air:

 

 

 

34°F (1.11°C)

 

 

 

34°F (1.44°C)

Evaporator Temperature:

 

 

28°F (-2.22°C)

 

 

 

28°F (-2.22°C)

 

 

 

 

 

 

 

 

 

 

 

Defrost (Off-cycle)

Medium Temperature

 

Medium Temperature

 

 

 

 

 

 

 

 

 

 

 

 

Frequency: (time per day)

 

6, once every 4 hours

 

6, once overy 4 gours

Termination Temperature:

 

 

50.0°F

 

 

 

 

 

50.0°F

 

 

Failsafe/Duration:

 

 

30 minutes

 

 

 

30 minutes

 

 

 

 

 

 

 

 

 

 

 

 

Electrical

 

 

 

1-phase 120V

 

 

 

1-phase 120V

Anti-condensation Heater

 

 

N/A

 

N/A

 

 

 

N/A

 

N/A

Fan Motor

Standard:

 

 

195W

 

2.28A

 

 

 

285W

 

3.42A

High Efficiency:

 

 

84W

 

1.29A

 

 

 

126W

 

1.93A

 

 

 

 

 

 

 

 

 

 

 

Exterior:

2 Rows of Lamps

 

110W

 

0.94A

2 Rows of Lamps

 

 

166W

 

1.42A

Lights

Interior:

Top Panel

 

N/A

 

N/A

Top Panel

 

 

N/A

 

N/A

Handrail

 

N/A

 

N/A

Handrail

 

 

N/A

 

N/A

 

 

 

 

 

 

 

 

 

 

Total:

Standard

 

110W

 

0.94A

Standard

 

 

166W

 

1.42A

Components

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Anti-condensation heater

 

 

N/A

 

 

 

 

 

N/A

 

 

Fan

 

Standard

 

 

SPFBE141 x 3

SPFBE141 x 3 , SPFBE91T x 2

Motor

 

High Efficiency:

 

SSC2B12CNHBV1 x 3

SSC2B12CNHBV1 x 3 , SSC2B12BVHBV1 x 2

Fan Blade Pitch

Inside:128×2, Outside:128 x 1

Inside:128 x 3, Outside:117 x 2

Illumination

 

FO32/XP (T8) (Output 32W)

FO32/XP (T8) (Output 32W)

Pipe Diameter

 

Liquid 3/8”, Suction 3/4”

Liquid 3/8”, Suction 3/4”

 

 

 

 

 

 

 

 

 

 

 

 

Measurements

 

 

 

 

 

 

 

 

 

 

 

Outer Dimensions

80 7/8” (H) × 42 1/2” (W) × 96 3/8” (L)

80 7/8” (H) × 42 1/2” (W) × 144 5/8” (L)

Open Space

 

 

 

60”

 

 

 

 

 

60”

 

 

Display Area

 

 

 

73.4 sq.ft.

 

 

 

110.1 sq.ft

Effective Capacity

 

 

72.0 cu.ft.

 

 

 

108.0 cu.ft.

Weight

 

 

 

609.0 lbs

 

 

 

875.0 lbs

Waste Outlet Dimensions

 

 

1 1/2”

 

 

 

 

 

1 1/2”

 

 

Standard Ambient Conditions: Indoor temperature 75°F (24°C), relative humidity 55%, wind speed under 39.4 fpm.

All specifications are based upon temperature, humidity, and wind speed values equal to or less than Standard Ambient Conditions.

SANYO Cases described in this manual are designed for indoor use only. SANYO Cases should not be exposed to direct sunlight.

Fan motors are available in Standard-type (AC fan motors) or High Efficiency-type (DC fan motors).

Display Area Effective Capacity data specification based on 4 (four) 20” shelves set at 0° (flat). Any variations from this specification will affect overall data.

6

Image 6
Contents MULTI-DECK Fresh Produce Cases 80 7/8, L 96 3/8 / H 80 7/8, L 144 5/8Activity Safety Precautions Table of Contents Care and Cleaning Guidelines Specifications CVW-EXA284 CVW-EXA224CVW-EXA184 CVW-EXA124 Dimensions External Dimensions FootprintCVW-EXA184 / CVW-EXA124 NSF Certification Unloading and Carpentry ProceduresUnloading Instructions & Precautions LocationAligning Cases Case LevelingJoining Instructions  Perimeter gasket is required by NSFConnecting cases Installing Patch Ends CVW-EXA284/224CVW-EXA184/124 Installing Kickplate Installing Handrail and Bumper Refrigeration, Plumbing & Electrical Procedures Piping Plumbing, RefrigerationWiring Color Code Electrical Guidelines & PrecautionsWiring Electrical DataWiring Diagram Operation Load LimitsInstalling FDA/NSF Thermometer MagnetCare and Cleaning Guidelines Exterior Panels Daily CleaningMirrors, Fluorescent Lamps, Drain Trap Monthly Cleaning Honeycomb Assemblies at least every 3 months Service Replacing Fan Motors and BladesTo replace the fan motors For models with Standard-type AC Fan Motors For models with high-efficiency-type DC fan motors Replacing Electronic Ballasts To replace electronic ballastsReplacing Fluorescent Lamps Lamp Cover END CAPExpansion Valve Danfoss SporlanPage Sanyo E & E Corporation