Sanyo CVW-EXA184, CVW-EXA124 service manual Specifications, CVW-EXA284 CVW-EXA224

Page 5

1 Specifications

1.1CVW-EXA284 (H: 84 7/8”, L: 96 3/8”) / CVW-EXA224 (H: 84 7/8”, L: 144 5/8”)

Model Name

 

CVW-EXA284

 

 

 

 

CVW-EXA224

General

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Application:

 

Medium Temperature (Fresh Produce)

Medium Temperature (Fresh Produce)

Cooling Capacity:

1224 BTU/h/ft. 2,880W

 

1224 BTU/h/ft.

4,321W

Discharge Air:

 

 

34°F (1.11°C)

 

 

 

 

34°F (1.11°C)

Evaporator Temperature:

 

 

28°F (-2.22°C)

 

 

 

 

28°F (-2.22°C)

 

 

 

 

 

 

 

 

 

 

 

Defrost (Off-cycle)

Medium Temperature

 

 

Medium Temperature

 

 

 

 

 

 

 

 

 

 

 

 

Frequency: (times per day)

 

6, once every 4 hours

 

 

6, once every 4 hours

Termination Temperature:

 

 

50.0°F

 

 

 

 

50.0°F

Failsafe/Duration:

 

 

30 minutes

 

 

 

 

30 minutes

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical

 

 

 

1-phase 120V

 

 

 

 

1-phase 120V

Anti-condensation Heater:

 

 

N/A

 

N/A

 

 

 

N/A

 

N/A

Fan

 

Standard:

 

 

195W

 

2.28A

 

 

 

285W

 

3.42A

Motor

 

High Efficiency:

 

 

84W

 

1.29A

 

 

 

126W

 

1.93A

 

 

Exterior:

2 Rows of Lamps

 

110W

 

0.94A

2 Rows of Lamps

 

 

166W

 

1.42A

Lights

 

Interior:

Top Panel

 

N/A

 

N/A

Top Panel

 

 

N/A

 

N/A

 

Handrail

 

N/A

 

N/A

Handrail

 

 

N/A

 

N/A

 

 

 

 

 

 

 

 

 

 

Total:

Standard

 

110W

 

0.94A

Standard

 

 

166W

 

1.42A

Components

 

 

 

 

 

 

 

 

 

 

 

Anti-condensation Heater

 

 

N/A

 

 

 

 

N/A

 

 

Fan

 

Standard:

 

 

SPFBE141 x 3

 

SPFBE141 x 3 , SPFBE91T x 2

Motor

 

High Efficiency:

 

SSC2B12CNHBV1 x 3

 

SSC2B12CNHBV1 x 3 , SSC2B12BVHBV1 x 2

Fan Blade Pitch:

Inside:128×2, Outside:128 x 1

Inside:128 x 3, Outside:117 x 2

Illumination:

 

FO32/XP (T8) (Output 32W)

 

FO32/XP (T8) (Output 32W)

Pipe Diameter:

Liquid 3/8”, Suction 3/4”

 

Liquid 3/8”, Suction 3/4”

 

 

 

 

 

 

 

 

 

 

 

 

Measurements

 

 

 

 

 

 

 

 

 

 

 

Outer Dimensions:

84 7/8” (H) × 42 1/2” (W) × 96 3/8” (L)

84 7/8” (H) × 42 1/2” (W) × 144 5/8” (L)

Open Space:

 

 

 

61 1/2”

 

 

 

 

61 1/2”

Display Area:

 

 

 

73.4 sq.ft.

 

 

 

 

110.1 sq.ft

Effective Capacity:

 

 

72.0 cu.ft.

 

 

 

 

108.0 cu.ft.

Weight:

 

 

 

620.5 lbs

 

 

 

 

892.0 lbs

Waste Outlet Dimensions:

 

 

1 1/2”

 

 

 

 

1 1/2”

Standard Ambient Conditions: Indoor temperature 75°F (24°C), relative humidity 55%, wind speed under 39.4 fpm.

All specifications are based upon temperature, humidity, and wind speed values equal to or less than Standard Ambient Conditions.

SANYO Cases described in this manual are designed for indoor use only. SANYO Cases should not be exposed to direct sunlight.

Fan Motors are available in Standard-type (AC Fan Motors) or High Efficiency-type (DC Fan Motors).

Display Area Effective Capacity data specification based on 4 (four) 20” shelves set at 0° (flat). Any variations from this specification will affect overall data.

5

Image 5
Contents 80 7/8, L 96 3/8 / H 80 7/8, L 144 5/8 MULTI-DECK Fresh Produce CasesActivity Safety Precautions Table of Contents Care and Cleaning Guidelines CVW-EXA284 CVW-EXA224 SpecificationsCVW-EXA184 CVW-EXA124 External Dimensions Footprint DimensionsCVW-EXA184 / CVW-EXA124 Unloading Instructions & Precautions Unloading and Carpentry ProceduresNSF Certification LocationCase Leveling Aligning Cases Perimeter gasket is required by NSF Joining InstructionsConnecting cases CVW-EXA184/124 Installing Patch EndsCVW-EXA284/224 Installing Kickplate Installing Handrail and Bumper Piping Plumbing, Refrigeration Refrigeration, Plumbing & Electrical ProceduresWiring Electrical Guidelines & PrecautionsWiring Color Code Electrical DataWiring Diagram Load Limits OperationMagnet Installing FDA/NSF ThermometerMirrors, Fluorescent Lamps, Drain Trap Monthly Cleaning Care and Cleaning GuidelinesExterior Panels Daily Cleaning Honeycomb Assemblies at least every 3 months To replace the fan motors ServiceReplacing Fan Motors and Blades For models with Standard-type AC Fan Motors For models with high-efficiency-type DC fan motors To replace electronic ballasts Replacing Electronic BallastsLamp Cover END CAP Replacing Fluorescent LampsSporlan Expansion Valve DanfossPage Sanyo E & E Corporation