7.2Replacing Electronic Ballasts

Ballast

Exterior Top

Panel

To replace electronic ballasts:

Remove the Exterior Top Panel.

Unplug the Electronic Ballast Harness(es).

Remove the Electronic Ballast(s).

Electronic Ballast Part Codes

Type

Model

Part Number

CVW-EXA124/224

CVW-EXA184/284

Quantity used

Quantity used

 

 

 

3-lamp

QHE3X32T8/UNV ISN-SC-1-CC-B

8FC05400000301

2

-

 

 

 

 

 

2-lamp

QHE2X32T8/UNV ISN-SC-1-CC-B

8FC05400000201

-

2

 

 

 

 

 

WARNING!

Make sure that all Electronic Ballasts Harness plugs are placed firmly in their sockets to prevent damage to the ballast and/or the case.

26

Image 26
Contents MULTI-DECK Fresh Produce Cases 80 7/8, L 96 3/8 / H 80 7/8, L 144 5/8Activity Safety Precautions Table of Contents Care and Cleaning Guidelines Specifications CVW-EXA284 CVW-EXA224CVW-EXA184 CVW-EXA124 Dimensions External Dimensions FootprintCVW-EXA184 / CVW-EXA124 NSF Certification Unloading and Carpentry ProceduresUnloading Instructions & Precautions LocationAligning Cases Case LevelingJoining Instructions  Perimeter gasket is required by NSFConnecting cases CVW-EXA184/124 Installing Patch EndsCVW-EXA284/224 Installing Kickplate Installing Handrail and Bumper Refrigeration, Plumbing & Electrical Procedures Piping Plumbing, RefrigerationWiring Color Code Electrical Guidelines & PrecautionsWiring Electrical DataWiring Diagram Operation Load LimitsInstalling FDA/NSF Thermometer MagnetMirrors, Fluorescent Lamps, Drain Trap Monthly Cleaning Care and Cleaning GuidelinesExterior Panels Daily Cleaning Honeycomb Assemblies at least every 3 months To replace the fan motors ServiceReplacing Fan Motors and Blades For models with Standard-type AC Fan Motors For models with high-efficiency-type DC fan motors Replacing Electronic Ballasts To replace electronic ballastsReplacing Fluorescent Lamps Lamp Cover END CAPExpansion Valve Danfoss SporlanPage Sanyo E & E Corporation