Bostitch 175869REVA, CAP2000P-OF manual Electrical Grounding Instructions, Safety Valve

Page 5

ELECTRICAL GROUNDING INSTRUCTIONS:

This product should be electrically grounded. In the event of an electrical short circuit, grounding reduces the risk of electrical shock by providing an escape wire for electrical current. This product is equipped with a cord having a grounding wire with an appropriate grounding plug. The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances.

DANGER: IMPROPER INSTALLATION OF THE GROUNDING PLUG CAN RESULT IN A RISK OF ELECTRIC SHOCK. If a repair or replacement cord is necessary, do not connect the grounding wire to either flat blade terminal. Check with a qualified electrician or serviceman, if the grounding instructions are not completely understood or if there is doubt as to whether this product is properly grounded. Do not modify the plug provided. If the supplied plug does not fit the outlet, have the proper outlet installed by a qualified electrician.

This product is shipped for use on a nominal 120-volt circuit, and has a grounding plug that looks like the plug in sketch A. A temporary adapter that looks like the adapter illustrated in sketches B and C may be used to connect this plug to a 2-pole receptacle as shown in sketch B, if a properly grounded outlet is not available. The temporary adapter should be used only until a properly grounded outlet (sketch A) can be installed by a qualified electrician. The green colored rigid ear, lug, or like extending from the adapter must be connected to a permanent ground such as a properly grounded outlet box cover. Whenever the adapter is used, it must be held in place by a metal screw.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

Cover of

 

 

B

 

 

 

 

 

 

grounded

 

 

 

 

 

 

 

 

 

 

 

Metal Screw

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

outlet box

 

 

 

 

Grounding Pin

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Grounding Means

 

 

 

Grounding Pin

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The motor of this compressor has a thermal overload protector in the motor winding. If the motor should overheat, the overload protector will shut the motor off. When the temperature returns to normal, the motor will restart automatically.

NOTICE! Do not stop the compressor by pulling out the plug. Use only the On/Off switch, which operates a pressure relief valve on the compressor. If the compressor is plugged in with the switch in the “On” position, the compressor may have trouble restarting against the high pressure which could cause excessive heat build up and could damage the motor.

Safety Valve:

This compressor is equipped with a safety valve that is set to avoid over-pressurization of the air tanks. This valve is factory pre-set at 160 PSI and will not function unless tank pressure reaches this pressure. DO NOT ATTEMPT TO ADJUST OR ELIMINATE THIS SAFETY DEVICE. ANY ADJUSTMENTS TO THIS VALVE COULD CAUSE SERIOUS INJURY. If this device requires service or maintenance, see an Authorized BOSTITCH Service Center.

5

Image 5
Contents Stanley Fastening Systems L.P 175869REVA 10/07 Index IntroductionRules for Safe Operation Attachments and AccessoriesBe Educated Avoid Moving Parts Personal ProtectionAir Tank Rules for Safe OperationVentilation Risk of BurnsElectrical Grounding Instructions Safety ValveElectrical Grounding Instructions CAP2000P-OF SpecificationsFeatures of the Bostitch CAP2000P-OF Operation Instructions General MaintenanceLimited Warranty Problem Probable Cause Correction Trouble Shooting GuideÍndice IntroducciónReglas Para EL Funcionamiento Seguro Tanques de aire Reglas Para EL Funcionamiento Seguro continuaciónVentilación Peligro de quemadurasVálvula de seguridad Instrucciones DE Conexión Eléctrica a TierraInstrucciones DE Conexión Eléctrica a Tierra continuación CAP2000P-OF EspecificacionesMedidor de presión regulada ElE Características DEL Bostitch CAP2000P-OFMantenimiento General Instrucciones DE OperaciónGarantía Limitada Problema Causa probable Corrección Guía Para Solucionar ProblemasIndex Renseignez-vous Embouts et accessoiresÉvitez les pièces mobiles Protection personnelleRéservoirs d’air Règles Pour UNE Utilisation Sécuritaire suiteVentilation Risque de brûluresSoupape de sûreté Instructions DE Mise À LA TerreCAP2000P-OF Instructions DE Mise À LA Terre suiteCaractéristiques DU Bostitch CAP2000P-OF Entretien Général Instructions D’UTILISATIONGarantie Limitée Guide DE Dépannage Problème Cause probable SolutionPage Page