Carrier 50PCH specifications A50-8490

Page 11

Complete C

11

LEGEND

AL

Alarm Relay Contacts

LOC

Loss of Charge Pressure Switch

BM

Blower Motor

MV

Motorized Valve

BMC

Blower Motor Capacitor

MVES

Motorized Valve End Switch

BR

Blower Relay

NEC

National Electrical Code

CAP

Compressor Capacitor

P1

Field Wiring Terminal Block

CB

Circuit Breaker

PSC

Permanent Split Capacitor

CC

Compressor Contactor

RV

Reversing Valve Coil

CO

Sensor, Condensate Overflow

TRANS

Transformer

FP1

Sensor, Low Temperature Protection Water Coil

TXV

Thermostatic Expansion Valve

FP2

Sensor, Low Temperature Protection Air Coil

 

Field Line Voltage Wiring

HP

High-Pressure Switch

 

Field Low Voltage Wiring

HPWS — High-Pressure Water Switch

 

 

Printed Circuit Trace

HWTS

High Leaving Water Temperature Switch

 

JW1

Jumper, Alarm

 

Optional Wiring

 

 

 

*Optional.

Relay/Contactor Coil

Condensate Pan

Solenoid Coil

Temperature Switch

a50-8490

 

Thermistor

 

Ground

 

Wire Nut

 

NOTES:

1.Compressor and blower motor thermally protected internally.

2.All wiring to the unit must comply with NEC and local codes.

3.Transformer for 208/230 v will be connected for 208 v operation. For 230 v operation, switch RED wire to ORG wire. Insulate open end of RED lead. Transformer is energy limiting or may have circuit breaker.

4.FP1 thermistor provides freeze protection for water. When using anti- freeze solutions, cut JW3 jumper.

5.Typical heat pump thermostat wiring shown. Refer to thermostat installa- tion instructions for wiring to the unit. Wire “Y” from thermostat to “Y” Complete C when a motorized valve is not used. “O” terminal is not used in cooling only applications. Thermostat wiring must be Class 1 and volt- age rating equal to or greater than unit supply voltage.

6.24-v alarm signal shown. For dry alarm contact, cut JW1 jumper and for anti-freeze solutions, cut JW3 jumper.

7.Transformer secondary ground via green wire with yellow stripe from “C” terminal to control box.

8.Hot water generator pump only in models with hot water generation and internal pump option.

9.For auxiliary staging options, consult electric heat installation manual.

10.Fan motors factory wired for medium speed. For high or low speed, remove BLU wire from fan motor speed trap “M” and connect to “H” for high speed or “L” for low speed.

11.Aquastat is with unit and must be wired in series with the hot leg to the pump. Aquastat is rated for voltage up to 277 v.

Fig. 13 — 50PCH,PCV Units with Complete C Controller, Single-Phase

Image 11
Contents Safety Considerations ContentsGeneral InstallationPhysical Data 50PCH,PCV Units IPT A50-8695Size Electric Heat A50-7842efA50-8696 Back Discharge Side DischargeA50-6260ef Install Condensate DrainMount the Unit A50-8489Copper FPT/PVC A50-6261tfA50-6262ef Metal Hose Minimum Bend RadiiFitting Wire Field Power SupplyA50-8490 Reversing Valve Solenoid Sensor, Low Temperature Protection Air CoilA50-8491 RVSHpws A50-8492LON A50-8493A50-8440 National Electrical Code Optional Wiring Temperature Switch8697 A50Units with Deluxe D and Wshp Open Multiple Protocol Controls 8698Wshp Open Control A50-8162 50PCH,PCV Unit Electrical DataA50-8442 Wire Field ControlsA50-8441 SPT Sensors Rnet Wiring SpecificationsRnet Wiring Field-Supplied Sensors for Wshp Open ControllerPRE-START-UP PCV Speed Airflow CFM 50PCH,PCV Blower Performance Standard Unit50PCH,PCV Blower Performance High-Static Unit FAN Rated MINField Selectable Inputs Complete C Control Jumper Settings Refer toDeluxe D Control Jumper Settings Refer to , 15, Operating Limits DIP Switch Block S2 Accessory 1 Relay OptionsDIP Switch Block S2 Accessory 2 Relay Options START-UPCooling Heating Water Flow Rate GPM Unit Start-Up Cooling ModeWater Temperature Change Through Heat Exchanger Operating Limits 50PCH,PCV UnitsEntering Cooling Heating Water 50PC006 Typical Unit Operating Pressures and Temperatures50PC009 Typical Unit Operating Pressures and Temperatures 50PC012 Typical Unit Operating Pressures and TemperaturesTemp GPM/ton Pressure Heat 50PC015 Typical Unit Operating Pressures and Temperatures50PC018 Typical Unit Operating Pressures and Temperatures 50PC024 Typical Unit Operating Pressures and TemperaturesWater Air Temp 50PC030 Typical Unit Operating Pressures and Temperatures50PC036 Typical Unit Operating Pressures and Temperatures 50PC042 Typical Unit Operating Pressures and TemperaturesUnit Start-Up with Wshp Open Controls Unit Start-Up Heating Mode50PC048 Typical Unit Operating Pressures and Temperatures 50PC060 Typical Unit Operating Pressures and TemperaturesBACview6 Display Interface A50-8444Gpm 30 F 50 F 70 F 90 F 10 C 21 C 32 C 006 009 Coaxial Water Pressure DropPressure DROP, psi kPa Units with Wshp Open Multiple Protocol OperationUnits with Aquazone Complete C Control Units with Aquazone Deluxe D ControlPage Auxiliary Modulating Hot Water/Steam Heating Reheat Complete C and Deluxe D Board System Test Aquazone Deluxe D Control LED Indica Complete C Control LED Code Fault DescriptionsLED Status Description of Operation Alarm Relay LED Fault Description CodeESD ServiceDescription Status LED Test LED ’ to 4’ Refrigerant ChargingA50-6286ef A50-8163 TroubleshootingAir Coil Fan Motor Removal Reduced or no airflow in heat TroubleshootingAir temperature out of range Cooling mode FP1125 F orReduced airflow in cooling Reduced or no water flowSensor Appendix a Wshp Open Screen ConfigurationAlarm Status StatusConfiguration Appendix a Wshp Open Screen ConfigurationMaintenance System SettingsSchedule Test Appendix a Wshp Screen Open ConfigurationService Screen Name Configuration ServicePoint Name Password Editable Range Default Level Alarm Page Copyright 2011 Carrier Corporation II. START-UP 50PCH,PCV START-UP ChecklistA50-8446 Heating Cycle AnalysisCooling Cycle Analysis A50-8445

50PCH specifications

The Carrier 50PCH is a cutting-edge series of air-cooled chillers designed to deliver exceptional cooling performance in a wide range of commercial applications. Engineered with efficiency and reliability in mind, the 50PCH stands out for its innovative technologies and robust construction, making it a preferred choice for facility managers and HVAC professionals.

One of the main features of the Carrier 50PCH is its advanced scroll compressor technology. This system consists of high-efficiency scroll compressors that optimize energy consumption while maintaining consistent cooling output. The incorporation of variable speed technology enables the chillers to adapt to fluctuating load demands, resulting in significant energy savings and reduced operational costs.

The 50PCH chillers also boast a high energy efficiency ratio (EER) and coefficient of performance (COP), ensuring compliance with stringent energy regulations and standards. They are designed with eco-friendly refrigerants, which contribute to lower greenhouse gas emissions, making them an environmentally responsible choice for modern buildings.

In addition to its energy-efficient operation, the 50PCH series is equipped with advanced controls that allow for seamless integration into building management systems. The intuitive interface facilitates monitoring and adjustment of set points, ensuring optimal comfort conditions. Furthermore, the chillers come with extensive diagnostic capabilities, enabling proactive maintenance and reducing the risk of unexpected downtime.

The robust construction of the 50PCH series enhances durability and reliability. With an all-weather aluminum cabinet, these chillers are designed to withstand harsh environmental conditions, ensuring long-term performance. The units undergo rigorous testing to meet high industry standards for quality and reliability.

Another distinguishing characteristic of the Carrier 50PCH is its whisper-quiet operation. Engineered for low sound levels, these chillers minimize noise pollution in sensitive environments, such as hospitals, schools, or residential areas.

In summary, the Carrier 50PCH series combines exceptional performance, energy efficiency, and innovative technology in a robust and reliable package. It highlights the best in modern HVAC design, making it an ideal solution for a wide array of climate control needs in commercial and institutional settings. With its advanced features and commitment to sustainability, the 50PCH is undoubtedly a leader in the air-cooled chiller market.