Carrier specifications Physical Data 50PCH,PCV Units

Page 3

or an equivalent protective covering. Cap open ends of pipes stored on the jobsite. This precaution is especially important in areas where painting, plastering, or spraying of fireproof mate- rial, etc. is not yet complete. Foreign material that accumulates within the units can prevent proper start-up and necessitate costly clean-up operations.

Before installing any of the system components, be sure to examine each pipe, fitting, and valve, and remove any dirt or foreign material found in or on these components.

CAUTION

DO NOT store or install units in corrosive environments or in locations subject to temperature or humidity extremes (e.g., attics, garages, rooftops, etc.). Corrosive conditions and high temperature or humidity can significantly reduce performance, reliability, and service life. Always move units in an upright position. Tilting units on their sides may cause equipment damage.

INSPECT UNIT — To prepare the unit for installation, com- plete the procedures listed below:

1.Compare the electrical data on the unit nameplate with ordering and shipping information to verify that the correct unit has been shipped.

2.Verify that the unit is the correct model for the entering water temperature of the job.

3.Do not remove the packaging until the unit is ready for installation.

4.Verify that the refrigerant tubing is free of kinks or dents, and that it does not touch other unit components.

5.Inspect all electrical connections. Be sure connections are clean and tight at the terminals.

6.Loosen compressor bolts until the compressor rides freely on springs. Remove shipping restraints.

7.Remove the four 1/4 in. shipping bolts from compressor support plate (two bolts on each side) to maximize vibra- tion and sound alternation.

CAUTION

Failure to remove shipping brackets from spring-mounted compressors will cause excessive noise and could cause component failure due to added vibration.

8.Remove any blower support cardboard from inlet of the blower.

9.Locate and verify any accessory kit located in compressor section.

10.Remove any access panel screws that may be difficult to remove once unit is installed.

Table 1 — Physical Data — 50PCH,PCV Units

50PCH,PCV UNIT

006

 

 

009

 

 

012

 

015

 

 

018

 

024

 

030

 

 

036

 

042

 

048

 

 

060

COMPRESSOR (1 each)

 

 

 

 

 

 

Rotary

 

 

 

 

 

 

 

 

 

 

 

Scroll

 

 

 

 

 

REFRIGERANT TYPE

 

 

 

 

 

 

 

 

 

 

 

 

 

R-410A

 

 

 

 

 

 

 

 

 

 

 

 

Factory Charge (oz)

17

 

 

18.5

 

 

23

 

32

 

 

43

 

43

 

47

 

 

50

 

70

 

74

 

 

82

 

 

 

 

 

 

 

 

 

 

FAN MOTOR AND BLOWER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan Motor Type/Speeds

 

 

 

 

 

 

 

 

 

 

 

 

 

PSC/3

 

 

 

 

 

 

 

 

 

 

 

 

Fan Motor (hp)

1/25

 

 

1/10

 

 

1/10

 

1/6

 

 

1/6

 

1/4

 

3/4

 

 

1/2

 

3/4

 

3/4

 

 

1

 

 

 

 

 

 

 

 

 

 

Blower Wheel Size (Dia x W) (in.)

5 x 5

 

 

6 x 5

 

8 x 7

 

9 x 7

 

 

9 x 8

 

10 x 10

 

 

11 x 10

COAX VOLUME (gal.)

0.123

 

 

0.143

 

 

0.167

 

0.286

 

 

0.450

 

0.286

 

0.323

 

 

0.323

 

0.890

 

0.738

 

 

0.939

WATER CONNECTION SIZE FPT (in.)

 

 

 

 

 

 

1/2

 

 

 

 

 

 

 

3/4

 

 

 

 

 

1

HORIZONTAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air Coil Dimensions (H x W)(in.)

 

 

 

10 x 15

 

 

 

 

 

16 x 22

 

 

 

 

20 x 25

 

20 x 35

 

 

 

 

 

 

 

 

 

 

 

Standard Filter - (Qty)

 

(1) 10 x 18

 

 

(1) 16 x 25

 

(1) 18 x 25

 

 

(1) 20 x 28 or

 

(1) 20 x 24,

 

 

 

 

 

 

1 in. Throwaway

 

 

 

 

 

 

(2) 20 x 14

 

(1) 20 x 14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Weight (lb)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operating

103

 

 

105

 

 

114

 

153

 

 

158

 

174

 

182

 

 

203

 

218

 

263

 

 

278

 

 

 

 

 

 

 

 

Packaged

113

 

 

115

 

 

124

 

158

 

 

163

 

179

 

187

 

 

209

 

224

 

270

 

 

285

Corner Weight (lb)*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Left-Front

37

 

 

38

 

 

42

 

53

 

 

55

 

62

 

67

 

 

75

 

81

 

98

 

 

103

Right-Front

24

 

 

24

 

 

26

 

36

 

 

37

 

40

 

41

 

 

47

 

50

 

60

 

 

64

Left-Back

23

 

 

23

 

 

25

 

34

 

 

35

 

39

 

40

 

 

44

 

48

 

58

 

 

61

Right-Back

19

 

 

20

 

 

21

 

30

 

 

31

 

33

 

34

 

 

37

 

39

 

47

 

 

75

VERTICAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air Coil Dimensions (H x W)(in.)

 

 

 

10 x 15

 

 

 

 

 

20 x 17.25

 

 

 

 

24 x 17.75

 

24 x 28.25

 

 

 

 

 

 

 

 

 

 

 

Standard Filter - (Qty)

 

(1) 10 x 18

 

 

 

 

 

(1) 20 x 20

 

 

 

 

(1) 24 x 24

 

(1) 14 x 24,

1 in. Throwaway

 

 

 

 

 

 

 

 

 

 

 

(1) 18 x 24

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Weight (lb)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operating

103

 

 

105

 

 

114

 

153

 

 

158

 

189

 

197

 

 

203

 

218

 

263

 

 

278

 

 

 

 

 

 

 

 

 

 

Packaged

113

 

 

115

 

 

124

 

158

 

 

163

 

194

 

202

 

 

209

 

224

 

270

 

 

285

LEGEND

 

 

 

 

 

 

 

 

 

*Front is located at control box end.

 

 

 

 

 

 

 

FPT — Female Pipe Thread

 

 

 

 

 

 

 

 

 

NOTES:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. All units have grommet compressor mountings, and 1/2-in. and

PSC — Permanent Split Capacitor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3/4-in. electrical knockouts.

 

 

 

 

 

 

 

 

2. Maximum water working pressure is 500 psig.

3

Image 3
Contents Safety Considerations ContentsGeneral InstallationPhysical Data 50PCH,PCV Units A50-8695 SizeIPT Electric Heat A50-7842efA50-8696 Back Discharge Side DischargeA50-6260ef Install Condensate DrainMount the Unit A50-8489Copper FPT/PVC A50-6261tfA50-6262ef Metal Hose Minimum Bend RadiiFitting Wire Field Power SupplyA50-8490 Reversing Valve Solenoid Sensor, Low Temperature Protection Air CoilA50-8491 RVSHpws A50-8492LON A50-8493A50-8440 National Electrical Code Optional Wiring Temperature Switch8697 A50Units with Deluxe D and Wshp Open Multiple Protocol Controls 8698Wshp Open Control A50-8162 50PCH,PCV Unit Electrical DataWire Field Controls A50-8441A50-8442 SPT Sensors Rnet Wiring SpecificationsRnet Wiring Field-Supplied Sensors for Wshp Open ControllerPRE-START-UP PCV Speed Airflow CFM 50PCH,PCV Blower Performance Standard Unit50PCH,PCV Blower Performance High-Static Unit FAN Rated MINComplete C Control Jumper Settings Refer to Deluxe D Control Jumper Settings Refer to , 15,Field Selectable Inputs Operating Limits DIP Switch Block S2 Accessory 1 Relay OptionsDIP Switch Block S2 Accessory 2 Relay Options START-UPCooling Heating Water Flow Rate GPM Unit Start-Up Cooling ModeWater Temperature Change Through Heat Exchanger Operating Limits 50PCH,PCV UnitsEntering Cooling Heating Water 50PC006 Typical Unit Operating Pressures and Temperatures50PC009 Typical Unit Operating Pressures and Temperatures 50PC012 Typical Unit Operating Pressures and TemperaturesTemp GPM/ton Pressure Heat 50PC015 Typical Unit Operating Pressures and Temperatures50PC018 Typical Unit Operating Pressures and Temperatures 50PC024 Typical Unit Operating Pressures and TemperaturesWater Air Temp 50PC030 Typical Unit Operating Pressures and Temperatures50PC036 Typical Unit Operating Pressures and Temperatures 50PC042 Typical Unit Operating Pressures and TemperaturesUnit Start-Up with Wshp Open Controls Unit Start-Up Heating Mode50PC048 Typical Unit Operating Pressures and Temperatures 50PC060 Typical Unit Operating Pressures and TemperaturesBACview6 Display Interface A50-8444Coaxial Water Pressure Drop Pressure DROP, psi kPaGpm 30 F 50 F 70 F 90 F 10 C 21 C 32 C 006 009 Units with Wshp Open Multiple Protocol OperationUnits with Aquazone Complete C Control Units with Aquazone Deluxe D ControlPage Auxiliary Modulating Hot Water/Steam Heating Reheat Complete C and Deluxe D Board System Test Aquazone Deluxe D Control LED Indica Complete C Control LED Code Fault DescriptionsLED Status Description of Operation Alarm Relay LED Fault Description CodeService Description Status LED Test LEDESD Refrigerant Charging A50-6286ef’ to 4’ Troubleshooting Air Coil Fan Motor RemovalA50-8163 Reduced or no airflow in heat TroubleshootingAir temperature out of range Cooling mode FP1125 F orReduced airflow in cooling Reduced or no water flowSensor Appendix a Wshp Open Screen ConfigurationAlarm Status StatusConfiguration Appendix a Wshp Open Screen ConfigurationMaintenance System SettingsSchedule Appendix a Wshp Screen Open Configuration ServiceTest Configuration Service Point Name Password Editable Range Default LevelScreen Name Alarm Page Copyright 2011 Carrier Corporation II. START-UP 50PCH,PCV START-UP ChecklistA50-8446 Heating Cycle AnalysisCooling Cycle Analysis A50-8445

50PCH specifications

The Carrier 50PCH is a cutting-edge series of air-cooled chillers designed to deliver exceptional cooling performance in a wide range of commercial applications. Engineered with efficiency and reliability in mind, the 50PCH stands out for its innovative technologies and robust construction, making it a preferred choice for facility managers and HVAC professionals.

One of the main features of the Carrier 50PCH is its advanced scroll compressor technology. This system consists of high-efficiency scroll compressors that optimize energy consumption while maintaining consistent cooling output. The incorporation of variable speed technology enables the chillers to adapt to fluctuating load demands, resulting in significant energy savings and reduced operational costs.

The 50PCH chillers also boast a high energy efficiency ratio (EER) and coefficient of performance (COP), ensuring compliance with stringent energy regulations and standards. They are designed with eco-friendly refrigerants, which contribute to lower greenhouse gas emissions, making them an environmentally responsible choice for modern buildings.

In addition to its energy-efficient operation, the 50PCH series is equipped with advanced controls that allow for seamless integration into building management systems. The intuitive interface facilitates monitoring and adjustment of set points, ensuring optimal comfort conditions. Furthermore, the chillers come with extensive diagnostic capabilities, enabling proactive maintenance and reducing the risk of unexpected downtime.

The robust construction of the 50PCH series enhances durability and reliability. With an all-weather aluminum cabinet, these chillers are designed to withstand harsh environmental conditions, ensuring long-term performance. The units undergo rigorous testing to meet high industry standards for quality and reliability.

Another distinguishing characteristic of the Carrier 50PCH is its whisper-quiet operation. Engineered for low sound levels, these chillers minimize noise pollution in sensitive environments, such as hospitals, schools, or residential areas.

In summary, the Carrier 50PCH series combines exceptional performance, energy efficiency, and innovative technology in a robust and reliable package. It highlights the best in modern HVAC design, making it an ideal solution for a wide array of climate control needs in commercial and institutional settings. With its advanced features and commitment to sustainability, the 50PCH is undoubtedly a leader in the air-cooled chiller market.