Soldadora con Arcos Revestidos | Modelo WS0970 |
Model WS0970
Para ordenar repuestos, comuníquese con el distribuidor más cercano a su domicilio
Sírvase suministrarnos la siguiente información: | Puede escribirnos a: | |
- | Número del modelo | The Campbell Group |
- Número de Serie (de haberlo) | Attn: Parts Department | |
- | Descripción y número del repuesto según la | 100 Production Drive |
| lista de repuestos | Harrison, Ohio 45030 U.S.A. |
1
2
Lista de Repuestos - Modelo WS0970
Ref |
|
|
|
No. | Description | Part Number | Qty |
1 | Ensamblaje del portaelectrodos- No incluye el cordón eléctrico | WC200000AV | 1 |
2 | Pinza (No incluye el cordón) | WC100000AV | 1 |
3 | Etiqueta de seguridad (no se muestra) | DK687500AV | 1 |
4 | Martillo/cepillo cincelador (no se muestra) | WC803000AV | 1 |
5 | Máscara de mano (no se muestra) | WC801700AV | 1 |
6 | Lentes de la máscara de mano (no se muestra) | WC801100AV | 1 |
General Safety
(Continued)
explosion if not properly vented! Verify that any cylinder or container to be welded has an adequate ventilation hole, so that expanding gases can be released.
! WARNING
Do not breathe fumes that are produced by the arc welding operation. These
fumes are dangerous. If the welding area cannot be adequately ventilated, be sure to use an
●Keep the head and face out of the welding fumes.
●Do not perform electric arc welding operations on metals that are galvanized or cadmium plated, or contain zinc, mercury, or beryllium without completing the following precautions:
a.Remove the coating from the base metal.
b.Make sure that the welding area is well ventilated.
c.Use an
! WARNING
The electromagnetic field that is generated during arc welding may interfere with
the operation of various electrical and electronic devices such as cardiac pacemakers. Persons using such devices should consult with their physician prior to performing any electric arc welding operations.
● Route the electrode and work |
cables together and secure with |
equipment is turned off and electrode is removed. Be sure that cables are loosely coiled and out of the way. Be sure that all metal and slag has cooled.
ADDITIONAL SAFETY STANDARDS
ANSI Standard Z49.1 from American Welding Society, 550 N.W. LeJune Rd. Miami, FL 33126
Safety and Health Standards
OSHA 29 CFR 1910, from Superintendent of Documents, U.S. Government Printing Office, Washington, D.C. 20402
National Electrical Code
NFPA Standard 70, from National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02169
Safe Handling of Compressed Gases in Cylinders
CGA Pamphlet
Code for Safety in Welding and Cutting
CSA Standard W117.2, from Canadian Standards Association, Standards Sales, 178 Rexdale Boulevard, Rexdale, Ontario, Canada M9W 1R3
Cutting And Welding Processes
NFPA Standard 51B, from National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02169
Safe Practices For Occupational And
Educational Eye And Face
Protection
ANSI Standard Z87.1, from American National Standards Institute, 1430 Broadway, New York, NY 10018 Refer to the Material Safety Data Sheets and the manufacturers instructions for metals, electrodes, coatings and cleaners.
●The receptacle used for the welder must be properly grounded and the welder must be the only load on the power supply circuit. Refer to the Circuit Amps chart on page 1 for correct circuit capacity.
●The use of an extension cord is not recommended for arc welding machines. Extension cord use will significantly degrade the performance of the welder.
Assembly
HANDSHIELD
1.Cut detachable handle away from shield. Trim the excess plastic to remove sharp edges.
Figure 2
2. Insert filter lens.
Figure 3
7 | Electrodos de soldar (no se muestra) |
|
|
| 1/16” (1,6 mm) E6013 (tubo de 0,5 lbs [227 g]) | WE103501AV | + |
| 5/64” (2 mm) E6013 (tubo de 0,5 lbs [227 g]) | WE103001AV | + |
| 1/16” (1,6 mm) E7014 (tubo de 0,5 lbs [227 g]) | WE105501AV | + |
| 5/64” (2 mm) E7014 (tubo de 0,5 lbs [227 g]) | WE105001AV | + |
| 1/16” (1,6 mm) autoencendido (tubo de 0,3 lbs [136 g]) | WE110001AV | + |
8 | Casco de soldar (no se muestra) |
|
|
| Área de visión 2” x | WT100500AV | + |
| Área de visión | WT101000AV | + |
| Oscurecimiento automático | WT100600AV | + |
+Accesorios opcionales (no se incluyen con el soldador)
tape when possible. |
● Never wrap arc welder cables |
around the body. |
● Always position the electrode and |
work leads so that they are on the |
same side of the body. |
● Exposure to electromagnetic fields |
during welding may have other |
health effects which are not known. |
Always be sure
! WARNING that the welding area is secure and free of hazards (sparks, flames, glowing metal or slag) prior to leaving. Be sure that
Installation
Location
Selecting the proper location can significantly increase performance, reliability and life of the arc welder.
●For best results locate the welder in an environment that is clean and dry. Dust and dirt in the welder retain moisture and increase wear of moving parts.
●Store electrodes in a clean, dry location with low humidity to preserve the flux coating.
Figure 4
3.To attach the handle, place shield on a flat surface and press handle into place (See Figure 5).
www.chpower.com
34 Sp | 3 |
|