Kenmore 625.38376 owner manual Assemble Inlet Outlet ADAPTORS, or Single Bypass Valve

Page 11

ASSEMBLE INLET OUTLET ADAPTORS, OR SINGLE BYPASS VALVE

Complete the following steps to assemble the adaptors or bypass valve.

1.Close the shutoff valve on the house main water pipe, near the water meter or pressure tank, to turn off the water. See Fig. 7.

2.Shut off the gas or electric supply to the water heater. See Fig. 7.

3.Open the highest and lowest water faucets in your

house. This will let water drain from the pipes. Close faucets after water has drained.

4.Remove the main cover. See Fig. 8. Pull outward on two (2) tabs to release.

The salt hole cover remains attached to the main cover

when removed. Set both covers aside so they will not get scratched or broken.

INSTALL SEARS BYPASS VALVE AND / OR THE INLET OUTLET THREADED ADAPTORS

NOTE: If you will not install the bypass valve because you will have a three (3) valve bypass, skip steps 6 & 7, but do steps 5 and 8.

5.Visually check and remove any foreign materials from the valve inlet and outlet ports. See Fig. 9. Carefully remove the two large plastic clips (you will use them). Check to be sure the turbine and turbine support are firmly in place. See Fig. 10.

BYPASS VALVE:

6.Put a light coating of silicone grease on the o-ring seals and slide onto the bypass valve.

7.Push the bypass valve into the softener valve as far as it will go. Snap the two large holding clips into place, from the top down as shown. See Fig. 11.

CAUTION: Be sure the clips snap firmly into place so the bypass valve will not pull out. See Fig. 11.

INLET AND OUTLET THREADED ADAPTORS:

8.Put a light coating of silicone grease on the o-ring seals and slide into the threaded adaptors. Push the adaptors into the valve inlet and outlet ports, or bypass valve ports, as far as they will go. Both adaptors are the same and fit either port. Snap the two large holding clips into place, as shown. See Fig. 11.

CAUTION: Be sure the clips snap firmly into place so the tubes will not pull out. See Fig. 11.

Shutoff

Shutoff

. Pressure

Valve

Valve

L/Tank

 

Pump

Electrical

Panel

FIG. 7

Salt Hole Cover

FIG. 8

INSTALLING BYPASS VALVE, AND/OR

INLET AND OUTLET THREADED ADAPTORS

Clip (2)

Valve Outlet

Included with

Softener

Valve Inlet_

_.

Included with

 

 

 

 

Softener

 

 

FIG. 9

Questions? Call The Kenmore Water Line 1-800-426-9345

11

Image 11
Contents Save this Manual Repair or Parts ? Call toll freeDisclaimer of implied warranties limitation of remedies ONE Year Limited Warranty on Water SoftenerThree Year Limited Warranty on Electronic Parts TEN Year Limited Warranty Against LeaksQuestions? Page Parts Descriptions Small Parts InspectshipmentPipe Proper Order to Install Water Treating EquipmentPlan Your Installation Tools NeededValve Where to Install the Water SoftenerDraw Your Pipes Fittings Suggested Slab Foundation InstallationOUT FIG. a Before Installing Checks & TestsInlet and Outlet Threaded Adaptors Assemble Inlet Outlet ADAPTORS, or Single Bypass ValveBypass Valve Bypass Valve Turned Downward Installing Holding ClipsValve Bypass Connect the Softener Position Softener Into PlaceConnect Salt Tank Overflow Tubing Connect the Valve Drain HoseLeak Test House Main Water Shutoff ValvesSingle Bypass Cold Water Pipe Grounding Installgroundingclampbetween Thesoftenerinand OUT PipesWater Meter Jumper Wire Connecting TransformerIC ,IIU InstallcoversProgram the Timer Restart the Water HeaterSET Regeneration Time SET Present Time of DAYSET Water Hardness Number Hardness NumberSanitize Your Water Softener AS Follows Sanitize the Water SoftenerRemoving Additives Addingsalttothe StoragetankWater Softening Salt with Iron Unit plugged Into a continuously live outlet? Check List of STEP-BY-STEP Guides to InstallSalt Monitor System ExtrarechargeRecharge NOW Recharge TonightCalifornia Efficiency Requirement Clean Feature Clean Feature Minutes 97% Feature12 / 24 Hour Clock Gallons / Liters Maximum Days Between RegenerationsWater Flow Through the Softener Tank LightAverage Dally Gallons or Liters Recharge Time Remaining and Valve Position IndicatorsError Code Kenmores Ultra Cleansing FeatureRegeneration Soft Water Service and RegenerationService Water Flow Through Softener in Backwash Water Flow Through Softener Brining and Brine RinseElectronics Soft Water Service and Regeneration Automatic BypassWater Flow Through Softener Fast Rinse Salt Bridge Salt BridgeIron from Resin BED Keeping the Water Softener Clean Nozzle & VenturiCleaning Nozzle Protect the Water Softener from Freezing Drain ALL Water from SoftenerCorrection ProblemcauseChecklist to Help YOU Save Money Bypass Valves Model 383760 Timer Code H Model 393760 Timer Code HPressure Drop PSI vs. Flow Rate GPM Eration Check Wiring SchematicFaceplate Always Make These Initial Checks FirstMost Likely Less Likely Possible ProblemProcedure for Removing Error Code From Faceplate Manual Initiated Electronics DiagnosticsTimer PWA Replacement Troubleshooting Valve Position IndicatorsCycle Flow Rates Gallons PER MIN Checks, and the manual initiated diagnosticsFloat Setting Manualadvanceregeneration CheckTo Relieve Pressure RotaryvalveserviceDisassembly AssemblyBrining and Brine Rinse Cycle Valve Service CycleWater Flow Through the Softener Fill CycleFast Rinse Cycle Valve Backwash CycleFast Rinse Cycle Backwash CycleQuestions? Call The Kenmore Water Line Part Number Part Description Water Softener CompleteInlet Outlet Grounding Clamps Brine Valve Assembly Wear-Strip Seal Cross-Section View No. Number Part Description Your Home
Related manuals
Manual 48 pages 29.92 Kb Manual 48 pages 24.39 Kb

625.38376 specifications

The Kenmore 625.38376 is a versatile and efficient air purifier designed to enhance indoor air quality in various environments, including homes, offices, and other spaces. This model is particularly recognized for its impressive filtration capabilities and user-friendly features, making it a popular choice among consumers seeking cleaner air.

One of the standout features of the Kenmore 625.38376 is its advanced three-stage filtration system. This system includes a pre-filter, a true HEPA filter, and an activated carbon filter. The pre-filter captures larger particles such as dust and pet hair, which helps to extend the life of the HEPA filter. The true HEPA filter is capable of trapping 99.97% of particles as small as 0.3 microns, effectively removing allergens like pollen, smoke, and mold spores from the air. The activated carbon filter further enhances the unit's performance by absorbing odors and volatile organic compounds (VOCs), contributing to a fresher indoor environment.

In addition to its powerful filtration system, the Kenmore 625.38376 includes several user-friendly technologies and features. The air purifier is equipped with a smart air quality sensor that continuously monitors the air quality in real-time. This sensor automatically adjusts the fan speed based on the pollution levels detected, ensuring optimal cleaning performance without unnecessary energy consumption. Users can easily track air quality levels through an intuitive digital display that shows the current status.

Another significant characteristic of the Kenmore 625.38376 is its quiet operation. The unit is designed to operate at low noise levels, making it suitable for use in bedrooms and other quiet spaces. It features multiple fan speeds, allowing users to adjust the airflow according to their specific preferences and needs.

The Kenmore 625.38376 is also energy efficient, certified by ENERGY STAR. This certification assures consumers that the unit meets stringent energy efficiency guidelines, promoting lower electricity bills and a reduced environmental impact.

In summary, the Kenmore 625.38376 air purifier combines advanced filtration technologies, smart sensors, quiet operation, and energy efficiency to create a reliable solution for improved indoor air quality. Its thoughtful design and effective performance make it an excellent choice for individuals looking to breathe cleaner air in their homes.