Kenmore 625.38376 owner manual Valve, Where to Install the Water Softener

Page 7

outside

faucet

 

 

 

 

 

 

(hard

water)

-

 

 

 

outside faucet

 

 

 

 

 

 

(hard

water)

soft, cold

_

 

 

 

_

toR.O, faucet

 

water

._,_

_

_

Hard _,_ ,_

¢--

_-

SOwf_th

 

I

 

Shut-off [_-

II toR

......

 

 

 

i

.

-Valve

 

II

 

 

 

 

 

 

 

 

R.O.

wa!er

I _____</'

 

_II

haid

...... //

_

storage

nearer

i

I

- '

Ihll

water to

//

../_'_--JF> tank

 

J

I

 

IIII1

house

//

 

 

water

/4

gap

 

_

softener

/

.

_

 

 

floor

mare

"

 

drain

shutof

 

 

 

valve

 

 

 

 

 

 

FIG. 3

Typical Installation

WHERE TO INSTALL THE WATER SOFTENER

Review the following points before you choose a place

1.Place as close as possible but always after, the pressure tank (well water) or water meter (city water). See Fig. 3.

2.Place as close as possible to a water drain such as a floor drain, laundry tub, sump or standpipe. See Fig. 3.

3.Connect to the house main water pipe BEFORE THE WATER HEATER. See Fig. 3. Temperature of water going through the softener must not be more than 120°F (49°C). Hot water will damage inner softener parts. To reduce the risk of hot water backup, piping between the softener and water heater should be as long of a run as possible.

4.Keep outside faucets on hard water to save soft water and salt. See Fig. 3.

5.Do not install in a place where the softener could freeze. Damage caused by freezing voids the war- ranty by Sears, Roebuck and Co.

to put your softener.

6.Put the softener in a place where water damage is least likely to occur if it develops a leak. Sears or the manufacturer will not repair or pay for water damage.

7.A grounded, 120V electrical outlet is needed within 10 feet of the softener. See Fig. 3. This is to plug in the transformer. The softener has a 10 foot power cable. Be sure the outlet and transformer are in an inside place, to protect from wet weather. Use a continuously "live" outlet, which cannot be acci- dentally switched off.

8.When installing in an outside location, you must take the steps necessary to assure the softener, installa- tion plumbing, and wiring, are protected from the elements, contamination, vandalism, etc.

9.Keep the softener out of direct sunlight. The sun's heat can melt plastic parts.

Questions? Call The Kenmore Water Line 1-800-426-9345

Image 7
Contents Save this Manual Repair or Parts ? Call toll freeDisclaimer of implied warranties limitation of remedies ONE Year Limited Warranty on Water SoftenerThree Year Limited Warranty on Electronic Parts TEN Year Limited Warranty Against LeaksQuestions? Page Parts Descriptions Small Parts InspectshipmentPipe Proper Order to Install Water Treating EquipmentPlan Your Installation Tools NeededValve Where to Install the Water SoftenerDraw Your Pipes Fittings Suggested Slab Foundation InstallationOUT FIG. a Before Installing Checks & TestsBypass Valve Assemble Inlet Outlet ADAPTORS, or Single Bypass ValveInlet and Outlet Threaded Adaptors Valve Bypass Installing Holding ClipsBypass Valve Turned Downward Connect the Softener Position Softener Into PlaceConnect Salt Tank Overflow Tubing Connect the Valve Drain HoseSingle Bypass House Main Water Shutoff ValvesLeak Test Cold Water Pipe Grounding Installgroundingclampbetween Thesoftenerinand OUT PipesWater Meter Jumper Wire Connecting TransformerIC ,IIU InstallcoversProgram the Timer Restart the Water HeaterSET Regeneration Time SET Present Time of DAYSET Water Hardness Number Hardness NumberSanitize Your Water Softener AS Follows Sanitize the Water SoftenerWater Softening Salt with Iron Addingsalttothe StoragetankRemoving Additives Unit plugged Into a continuously live outlet? Check List of STEP-BY-STEP Guides to InstallSalt Monitor System ExtrarechargeRecharge NOW Recharge TonightCalifornia Efficiency Requirement Clean Feature Clean Feature Minutes 97% Feature12 / 24 Hour Clock Gallons / Liters Maximum Days Between RegenerationsWater Flow Through the Softener Tank LightAverage Dally Gallons or Liters Recharge Time Remaining and Valve Position IndicatorsError Code Kenmores Ultra Cleansing FeatureService Soft Water Service and RegenerationRegeneration Water Flow Through Softener in Backwash Water Flow Through Softener Brining and Brine RinseWater Flow Through Softener Fast Rinse Soft Water Service and Regeneration Automatic BypassElectronics Salt Bridge Salt BridgeCleaning Nozzle Keeping the Water Softener Clean Nozzle & VenturiIron from Resin BED Protect the Water Softener from Freezing Drain ALL Water from SoftenerChecklist to Help YOU Save Money ProblemcauseCorrection Bypass Valves Model 383760 Timer Code H Model 393760 Timer Code HPressure Drop PSI vs. Flow Rate GPM Eration Check Wiring SchematicFaceplate Always Make These Initial Checks FirstMost Likely Less Likely Possible ProblemProcedure for Removing Error Code From Faceplate Manual Initiated Electronics DiagnosticsTimer PWA Replacement Troubleshooting Valve Position IndicatorsCycle Flow Rates Gallons PER MIN Checks, and the manual initiated diagnosticsFloat Setting Manualadvanceregeneration CheckTo Relieve Pressure RotaryvalveserviceDisassembly AssemblyBrining and Brine Rinse Cycle Valve Service CycleWater Flow Through the Softener Fill CycleFast Rinse Cycle Valve Backwash CycleFast Rinse Cycle Backwash CycleQuestions? Call The Kenmore Water Line Part Number Part Description Water Softener CompleteInlet Outlet Grounding Clamps Brine Valve Assembly Wear-Strip Seal Cross-Section View No. Number Part Description Your Home
Related manuals
Manual 48 pages 29.92 Kb Manual 48 pages 24.39 Kb

625.38376 specifications

The Kenmore 625.38376 is a versatile and efficient air purifier designed to enhance indoor air quality in various environments, including homes, offices, and other spaces. This model is particularly recognized for its impressive filtration capabilities and user-friendly features, making it a popular choice among consumers seeking cleaner air.

One of the standout features of the Kenmore 625.38376 is its advanced three-stage filtration system. This system includes a pre-filter, a true HEPA filter, and an activated carbon filter. The pre-filter captures larger particles such as dust and pet hair, which helps to extend the life of the HEPA filter. The true HEPA filter is capable of trapping 99.97% of particles as small as 0.3 microns, effectively removing allergens like pollen, smoke, and mold spores from the air. The activated carbon filter further enhances the unit's performance by absorbing odors and volatile organic compounds (VOCs), contributing to a fresher indoor environment.

In addition to its powerful filtration system, the Kenmore 625.38376 includes several user-friendly technologies and features. The air purifier is equipped with a smart air quality sensor that continuously monitors the air quality in real-time. This sensor automatically adjusts the fan speed based on the pollution levels detected, ensuring optimal cleaning performance without unnecessary energy consumption. Users can easily track air quality levels through an intuitive digital display that shows the current status.

Another significant characteristic of the Kenmore 625.38376 is its quiet operation. The unit is designed to operate at low noise levels, making it suitable for use in bedrooms and other quiet spaces. It features multiple fan speeds, allowing users to adjust the airflow according to their specific preferences and needs.

The Kenmore 625.38376 is also energy efficient, certified by ENERGY STAR. This certification assures consumers that the unit meets stringent energy efficiency guidelines, promoting lower electricity bills and a reduced environmental impact.

In summary, the Kenmore 625.38376 air purifier combines advanced filtration technologies, smart sensors, quiet operation, and energy efficiency to create a reliable solution for improved indoor air quality. Its thoughtful design and effective performance make it an excellent choice for individuals looking to breathe cleaner air in their homes.