POSITION SOFTENER INTO PLACE

Complete the following steps to position the softener.

1.Grip under the ridge on the salt tank sidewall.

2.Carefully rock back and forth into position.

3.Move the softener into position.

4.Place on a level and smooth surface. If needed, put a piece of 3/4" plywood, at least 17" x 20", under the tank. Then put spacers under the plywood to level the softener. See Fig. 14.

NOTE: Do not put shims or spacers directly under the tank, without the plywood. The weight of the sof- tener, when full of salt and water, may cause the tank to puncture or break at the shim or spacer.

CONNECT THE SOFTENER

Refer to your plan drawing. See Fig. 5.

Measure, cut (thread if needed) and put all pipe and fit- tings together up to the main water pipe, or to the bypass valve(s) you installed in the previous step.

MOVE SOFTENER INTO PLACE

Grip under ridge

II

to move softener.

 

::::1__

Plywo_Shims

FIG. 14

CAUTION: Never solder fittings while connected to

nonmetalfic parts. Wait until soldered pipe has

cooled before connection. See Fig. 15.

CAUTION: Be careful when putting pipe fittings together. Do not cross thread, and do not overtight-

en.

TYPICAL SOLDERING

CONNECTIONS

Main Water Pipe

Hard Water

4.Solder

NOTE: To be certain heat will not travel down the pipe and into the bypass valve (or installation adaptors), wrap the bottom of the pipe and the bypass valve in a wet rag.

I

1.Cut pipe to correct length.

2.Solder (WHEN COOL, do Step 3).

3.Put threaded adaptor into bypass valve port.

i

FIG. 15

Questions? Call The Kenmore Water Line 1-800-426-9345

13

Image 13
Contents Save this Manual Repair or Parts ? Call toll freeThree Year Limited Warranty on Electronic Parts ONE Year Limited Warranty on Water SoftenerTEN Year Limited Warranty Against Leaks Disclaimer of implied warranties limitation of remediesQuestions? Page Parts Descriptions Small Parts InspectshipmentPlan Your Installation Proper Order to Install Water Treating EquipmentTools Needed PipeValve Where to Install the Water SoftenerDraw Your Pipes Fittings Suggested Slab Foundation InstallationOUT FIG. a Before Installing Checks & TestsBypass Valve Assemble Inlet Outlet ADAPTORS, or Single Bypass ValveInlet and Outlet Threaded Adaptors Valve Bypass Installing Holding ClipsBypass Valve Turned Downward Connect the Softener Position Softener Into PlaceConnect Salt Tank Overflow Tubing Connect the Valve Drain HoseSingle Bypass House Main Water Shutoff ValvesLeak Test Water Meter Jumper Wire Installgroundingclampbetween Thesoftenerinand OUT PipesConnecting Transformer Cold Water Pipe GroundingProgram the Timer InstallcoversRestart the Water Heater IC ,IIUSET Water Hardness Number SET Present Time of DAYHardness Number SET Regeneration TimeSanitize Your Water Softener AS Follows Sanitize the Water SoftenerWater Softening Salt with Iron Addingsalttothe StoragetankRemoving Additives Unit plugged Into a continuously live outlet? Check List of STEP-BY-STEP Guides to InstallRecharge NOW ExtrarechargeRecharge Tonight Salt Monitor System12 / 24 Hour Clock Clean Feature Clean Feature Minutes 97% FeatureGallons / Liters Maximum Days Between Regenerations California Efficiency RequirementWater Flow Through the Softener Tank LightError Code Recharge Time Remaining and Valve Position IndicatorsKenmores Ultra Cleansing Feature Average Dally Gallons or LitersService Soft Water Service and RegenerationRegeneration Water Flow Through Softener in Backwash Water Flow Through Softener Brining and Brine RinseWater Flow Through Softener Fast Rinse Soft Water Service and Regeneration Automatic BypassElectronics Salt Bridge Salt BridgeCleaning Nozzle Keeping the Water Softener Clean Nozzle & VenturiIron from Resin BED Protect the Water Softener from Freezing Drain ALL Water from SoftenerChecklist to Help YOU Save Money ProblemcauseCorrection Bypass Valves Model 383760 Timer Code H Model 393760 Timer Code HPressure Drop PSI vs. Flow Rate GPM Faceplate Wiring SchematicAlways Make These Initial Checks First Eration CheckProcedure for Removing Error Code From Faceplate Possible ProblemManual Initiated Electronics Diagnostics Most Likely Less LikelyTimer PWA Replacement Troubleshooting Valve Position IndicatorsFloat Setting Checks, and the manual initiated diagnosticsManualadvanceregeneration Check Cycle Flow Rates Gallons PER MINDisassembly RotaryvalveserviceAssembly To Relieve PressureWater Flow Through the Softener Valve Service CycleFill Cycle Brining and Brine Rinse CycleFast Rinse Cycle Valve Backwash CycleBackwash Cycle Fast Rinse CycleQuestions? Call The Kenmore Water Line Part Number Part Description Water Softener CompleteInlet Outlet Grounding Clamps Brine Valve Assembly Wear-Strip Seal Cross-Section View No. Number Part Description Your Home
Related manuals
Manual 48 pages 29.92 Kb Manual 48 pages 24.39 Kb

625.38376 specifications

The Kenmore 625.38376 is a versatile and efficient air purifier designed to enhance indoor air quality in various environments, including homes, offices, and other spaces. This model is particularly recognized for its impressive filtration capabilities and user-friendly features, making it a popular choice among consumers seeking cleaner air.

One of the standout features of the Kenmore 625.38376 is its advanced three-stage filtration system. This system includes a pre-filter, a true HEPA filter, and an activated carbon filter. The pre-filter captures larger particles such as dust and pet hair, which helps to extend the life of the HEPA filter. The true HEPA filter is capable of trapping 99.97% of particles as small as 0.3 microns, effectively removing allergens like pollen, smoke, and mold spores from the air. The activated carbon filter further enhances the unit's performance by absorbing odors and volatile organic compounds (VOCs), contributing to a fresher indoor environment.

In addition to its powerful filtration system, the Kenmore 625.38376 includes several user-friendly technologies and features. The air purifier is equipped with a smart air quality sensor that continuously monitors the air quality in real-time. This sensor automatically adjusts the fan speed based on the pollution levels detected, ensuring optimal cleaning performance without unnecessary energy consumption. Users can easily track air quality levels through an intuitive digital display that shows the current status.

Another significant characteristic of the Kenmore 625.38376 is its quiet operation. The unit is designed to operate at low noise levels, making it suitable for use in bedrooms and other quiet spaces. It features multiple fan speeds, allowing users to adjust the airflow according to their specific preferences and needs.

The Kenmore 625.38376 is also energy efficient, certified by ENERGY STAR. This certification assures consumers that the unit meets stringent energy efficiency guidelines, promoting lower electricity bills and a reduced environmental impact.

In summary, the Kenmore 625.38376 air purifier combines advanced filtration technologies, smart sensors, quiet operation, and energy efficiency to create a reliable solution for improved indoor air quality. Its thoughtful design and effective performance make it an excellent choice for individuals looking to breathe cleaner air in their homes.