Elation Professional 575B manual Lamp off via external DMX controller, Lamp Off if no DMX

Page 27

Design Spot 575B™

don’t.

9.3.4. Lamp off via external DMX controller

With this function you can select if you can switch the lamp off via an external controller. Select “ON” by turning the LCD controls if you wish to enable this function or “OFF” if you don’t.

9.3.5. Lamp Off if no DMX

With this function you can select to switch off the lamp off automatically if there is no DMX signal). Select “ON” by turning the LCD controls if you wish to enable this function or “OFF” if you don’t.

9.3.6. Lamp on at temp.

With this function you can set the inside temperature from which the projector will strike the lamp after an automatic lamp shut off.

9.3.7. Lamp off at temp.

With this function you can set the inside temperature at which the projector will automatically switch the lamp off. Turn the LCD controls to select the maximum inside temperature between 80° C and 139° C. Inside temperatures below 90° C are not critical. 90° C and more should lead to the lamp being switched off. Please note that the outside temperature should not exceed 45° C.

9.4 Personality:

9.4.1.Status setting

A.Address via DMX - This function allows the DMX address to remotely be adjusted from a DMX console. This setting requires special settings for both the controller and the fixture. RDMX is on by default. For operational instructions please see Section 10/Page 32 of this manual “Remote DMX addressing.”

B.Run if no DMX – This function dictates how the fixture will function if it looses DMX signal during normal operation. The default function is set to hold, in which

©Elation Professional, Los Angeles CA.

27

Design Spot 575B™

Image 27
Contents Design Spot 575B Design Spot 575B Elation Professional, Los Angeles CA Contents General Information Design Spot 575B Never open this fixture while in use Safety Instructions Design Spot 575B Features General Guidelines Lamp Installation Instructions Safety RegulationsInstallation Procedure Lamp Optimization Design Spot 575B Mounting Mounting and InstallationClamp Mounting Mounting pointsSecuring the Design Spot 575B Understanding DMX DMX-512 control connection Fixture DMX addressing DMX-512 connection with DMX terminatorDesign Spot 575B PAN…… Fixture MenuPAN…… PAN =XXX XX~XX Music control Slave settingMenu Functions Auto ProgramLamp off time Time information Current timeTotal Run Time Total Lamp TimeAutomatic Lamp On Temp. InfoSoftware version Lamp on/offLamp on at temp Status settingLamp off via external DMX controller Lamp Off if no DMXDesign Spot 575B Design Spot 575B Effect Adjust User Mode DMX Addressing Controller Settings Operation Music Control submenu select Alone Working with BUILT-IN Programs Memory StatisticsBuilding Scenes Building Scenes from an External DMX Controller Playing a Program Editing ProgramsTilt Movement 8bit DMX Channel TraitsPAN Movement 8bit Pan Fine 16bitRotating gobo index, rotating gobo rotation Color WheelColor Wheel Fine Rotating gobos, cont. rotationFocus Fine Fixed gobo indexing FineFacet rotating prism, Prism / Gobo macros FocusIris Lamp on/off, reset, internal programsDimmer intensity Fine Dimmer intensityFuse Replacement Error Codes Pan ErTilt Er Prism Rotation Er Color ErRotation gobo Er Gobo Rotation ErIris Er Focus ErCleaning and Maintenance Year Limited Warranty Design Spot 575B Photometric Data Gobos Dimensional Drawings Circuit Schematic Gobos Technical SpecificationsDesign Spot 575B Elation Professional