5. LAMP INSTALLATION INSTRUCTIONS

For a proper and safe lamp change, please read this chapter carefully and follow all instructions.

Safety Regulations

Disconnect the unit’s main power supply.

Allow the unit to cool for at least 30 minutes before attempting any type of service.

Before you put the Design Spot 575B™ into operation be sure all covers have been replaced, otherwise you risk damage to the retina and expose to UV radiation!

Replace the lamp with an approved replacement type. Be sure to follow all the lamp handling procedures included with your new lamp. Never handle the new lamp with your bare hands as the oils from your skin may damage the lamp. Always replace with a lamp that meets the original lamp specification, failure to do so may damage the unit and will void your manufactures warranty.

Installation Procedure:

1.Set the fixture on a flat surface and remove the four screws labeled “A” “B,” “C,” and “D” found on the back plate of the head assembly.

2.Gently pull out the lamp/socket assembly to access the lamp.

3.Gently remove the old lamp by grasping it by metal ends.

4.Insert the new lamp securely, locking the lamp in place as illustrated in the diagram on the next page. Orientate the lamp filler tube towards the backside of the reflector. Before reassembling the unit, be sure the new lamp is securely seated in the lamp socket. Always be sure to only use specified lamp types! (MSR 575 lamp or equivalent).

©Elation Professional, Los Angeles CA.

11

Design Spot 575B™

Image 11
Contents Design Spot 575B Design Spot 575B Elation Professional, Los Angeles CA Contents General Information Design Spot 575B Never open this fixture while in use Safety Instructions Design Spot 575B Features General Guidelines Installation Procedure Lamp Installation InstructionsSafety Regulations Lamp Optimization Design Spot 575B Mounting Mounting and InstallationClamp Mounting Mounting pointsSecuring the Design Spot 575B Understanding DMX DMX-512 control connection Fixture DMX addressing DMX-512 connection with DMX terminatorDesign Spot 575B PAN…… Fixture MenuPAN…… PAN =XXX XX~XX Music control Slave settingMenu Functions Auto ProgramLamp off time Time information Current timeTotal Run Time Total Lamp TimeAutomatic Lamp On Temp. InfoSoftware version Lamp on/offLamp on at temp Status settingLamp off via external DMX controller Lamp Off if no DMXDesign Spot 575B Design Spot 575B Effect Adjust User Mode DMX Addressing Controller Settings Operation Music Control submenu select Alone Building Scenes Working with BUILT-IN ProgramsMemory Statistics Building Scenes from an External DMX Controller Playing a Program Editing ProgramsTilt Movement 8bit DMX Channel TraitsPAN Movement 8bit Pan Fine 16bitRotating gobo index, rotating gobo rotation Color WheelColor Wheel Fine Rotating gobos, cont. rotationFocus Fine Fixed gobo indexing FineFacet rotating prism, Prism / Gobo macros FocusIris Lamp on/off, reset, internal programsDimmer intensity Fine Dimmer intensityFuse Replacement Tilt Er Error CodesPan Er Prism Rotation Er Color ErRotation gobo Er Gobo Rotation ErIris Er Focus ErCleaning and Maintenance Year Limited Warranty Design Spot 575B Photometric Data Gobos Dimensional Drawings Circuit Schematic Gobos Technical SpecificationsDesign Spot 575B Elation Professional