Fedders A7Q08F2B important safety instructions Installation in Minimum Width Window, Inside View

Page 4

INSTALLATION

WINDOW INSTALLATON

6

Lower window sash

 

 

Level

 

 

 

Top bar

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Window sill

 

Bottom bar

 

 

1 1/4” space

 

 

 

 

 

Leveling bracket

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Screw

 

 

 

SIDE VIEW

 

 

 

 

 

 

 

 

 

Sill edge

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

Plastic foam seal

 

 

 

 

Upper window sash

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lower window sash

5/8” wood screws

Window sill

Filler panel

INSIDE VIEW

5.Keeping a firm grip on air conditioner, carefully center air conditioner in window opening with the bottom bar sitting behind window sill. Be sure cabinet maintains an outward pitch. Air conditioner should slant slightly downward on the outside as shown by half a bubble off on a carpenter’s level. This outward pitch prevents water from entering the room (Fig. 6).

6.Close window until it touches behind air conditioner top bar. Slide filler panels outward until they touch window sash tracks. (Do not release grip on air conditioner until lower window sash is in final position)

(Fig. 7).

7.Secure top of filler panels by driving 5/8” long wood screws through top mounting holes into window sash (Fig. 7).

8.Secure bottom of filler panels by driving 5/8” long screws into window sill through filler panel tabs (Fig. 7).

9.Cut plastic foam seal to width of window and install between upper and lower window sash (Fig. 7).

10.Use sealant to fill any minor openings.

Installation in Minimum Width Window

1.Remove both filler panels from air conditioner cabinet (Fig. 3).

2.Refer to steps 1 through 7 of preceding instructions (Pgs. 4 & 5).

3.Close window until it touches behind air conditioner top bar (Fig. 6).

4.Fasten lower window sash to window frame (use finishing nails, wood screws, or “L” brackets) (Fig. 7).

5.If filler is required on sides of air conditioner, cut plastic foam seal to size and fill both sides.

6.Cut plastic foam seal to width of window and install between upper and lower window sash (Fig. 7).

7.Use sealant to fill any minor openings.

Consult your authorized dealer or importer for alternative installation instructions.

CAUTION

Do not drill a hole in bottom pan. Unit is designed to operate with approximately 1/2” of water in bottom pan.

4

Image 4
Contents English GarantíaOr email customerservice@fedders.com InstallationImportant Grounding Requirements Installation in Normal Width Window Tools NeededWindow Requirements Unit & Window SizeInstallation in Minimum Width Window Inside ViewPower Control Set Temperature/Timer DisplayTemperature/Timer Hour Controls Check Filter Light/Reset some modelsTimer Control Air Conditioner Remote ControlTimer can be set to either turn the unit on or off To turn the unit on using the TimerCleaning Air Filter Occurrence Possible Cause SolutionsService Troubleshooting GuideHow to Obtain Warranty Service or Parts Room Air Conditioner WarrantyWarranty ExceptionsRiesgo de Choque Eléctrico Requerimientos Importantes para la Puesta a TierraInstalacion Precauciones de Seguridad AdicionalesHerramientas necesarias Requisitos de la ventanaTamaño de la ventana y de la unidad Instale los paneles de llenado En algunos modelosInstalación en una ventana de ancho mínimo Consultar los pasos 1 a 7 de las instrucciones precedentesControl de alimentación Pantalla de configuración de temperatura/relojControles de temperatura/hora del reloj Control de modoControl de velocidad del ventilador Control del relojControl Remoto de Acondicionador de Aire PRECAUCION´Problema Causa Posible Soluciones Localización y Solución de AveríasOrientación de la corriente de aire Limpieza del filtro de aireCómo obtener servicio o piezas bajo la garantía Garantía del acondicionador de aireGarantia ExcepcionesCordon électrique avec dispositif de détection darc Risque de choc électriqueAvertissement Dimensions de l’appareil et de la fenêtre Caractéristiques des fenêtresFixation des panneaux de remplissage Pose dans une fenêtre de largeur normalePose dans une fenêtre de largeur minimum Commande marche/arrêt Commandes de la température et du nombre d’heuresCommande du mode Commande de la vitesse de ventilationCommande de la minuterie Télécommande de ClimatiseurSymptôme Causes possibles Solutions PRECAUTION´Orientation de l’air Nettoyage du filtre à airPour les modèles installés en dehors de l’Amérique du Nord Garantie du climatiseurDépannage ET Garantie 800 332-6658 ou en écrivant àPage 23-23-0321N-011