Aquacal Heat Pump Winterizing and Troubleshooting Guide

Page 28

Winterizing Procedure:

1.Disconnect all electrical power to the heater; turn OFF circulating pump.

2.At the two (2) water connection unions, disconnect the plumbing to the heater (removal is counterclockwise).

3.Locate the drain plug at lower, right-hand, front corner of heater. (See Figures 1 & 2, below.)

4.Using a 5/8", box-end wrench, remove the drain plug (removal is counterclockwise).

5.Permit all of the water to drain out of the condenser, and then replace the plug: thread the plug in clockwise until just snug, then apply an additional 1/8 turn.

6.To prevent insects and vermin from entering the plumbing during the winterized period, partially reconnect the two (2) plumbing connection unions: couple each union one or two threads; this will permit condensation to drain, but will prevent most insects and animals from entering the plumbing circuit.

7.Next Season: to ready the heat pump for use, simply retighten plumbing connection unions. Hand-tight is generally sufficient.

Location of Winterizing Drain

FIGURE 1

FIGURE 2

28

Image 28
Contents Pool and Spa Heat Pump Installation Guide Page Table of Contents Eam Important Features Your NEW Heat Pump ThermoLink Heat ExchangerSafety Information Water Temperature SafetyWater Chemistry Safety Heater not Repairable by OwnerQuick Start & Stop Physical Characteristics Performance Dimensional Information TropiCal Models T65 and T115Dimensional Information TropiCal Model T135 TropiCal Table of Specifications Refrigerant Circuit Performance ChartsRefrigerant Circuit Performance Charts Guide Troubleshooting Refrigerant Circuit Problems Possible ConditionsInstallation Placement of HeaterIndoor Installation Outdoor InstallationTypical Installation Clearances Irrigation, Rainwater Runoff, and Landscape FeaturesEquipment Pad Requirements Anchoring Heater to PadPlumbing Requirements Plumbing Schematics Water in & OUT Connections Electrical RequirementsGeneral Information Code Requirements Reference Equipment Data PlateSTART-UP & Operation Getting Familiar with ControlsOverview of Controls Initial Start-Up and Basic OperationHeating Tips Pool/Spa BlanketsCalculating Initial Heating Time Pool and Spa Combination HeatingSpa Heating Heating in Cooler Weather Defrost CycleMaintenance Planned Maintenance Program General MaintenanceMaintaining Proper Water Flow Seasonal USE & Shut Down Maintaining Proper Clearances Around HeaterDuring the Swim Season Freeze protection / Extended shut downsWinterizing Procedure Location of Winterizing DrainTroubleshooting Common Troubleshooting IssuesHeat Pump Not Running Heat Pump Running but Not HeatingTroubleshooting Flow Charts Heater Fails to OperateHeater Running but Not Heating Analog or Digital Controls 12/22/03Determining Water Leaks vs. Condensation StartHeater Short Cycling If the heater is turning on Off every 5 minutesReplacement Parts Part Description Part NumberWhat We Need to Know When You Call Us Contacting the Factory2737 24th St. North St. Petersburg, FL