Grizzly owner manual To set the inward 45º stop, Adjusting the inward stop G0612 6 Jointer

Page 22

6.Loosen the fence tilting handle, bring the fence to 90º with the machinist's square set against the fence, then tighten the handle.

Note: Keep the limit plate tab in the rear slot of the limit block.

7.Loosen the jam nut (located at the rear of the limit block shaft).

8.Using a screwdriver, turn the limit block set screw until the limit block shaft hits the fence.

9.Tighten the jam nut. The 90º stop is now set precisely.

To set the inward 45º stop:

1.DISCONNECT THE JOINTER FROM THE POWER SOURCE!

2.With the fence positioned over the bed and the sliding handle locked, loosen the fence tilting handle.

3.Tip the fence towards the table as far as it will go, then tighten the fence tilting handle.

Note: When you tip the fence towards the table, it will stop when it hits the inward stop bolt.

4.Use a machinist's combination square to check the angle of the fence as shown in Figure 25.

Figure 25. Checking the inward 45º stop.

—If the fence leans 45º towards the table, the inward 45º stop is set correctly; move ahead to set the outward 45º stop.

—If the fence does not lean 45º towards the table, adjust the inward 45º stop by doing Steps 5-9.

5.Loosen the fence tilting handle, bring the fence to 90º, then tighten the handle just enough to keep the fence in position.

6.Remove the limit block from the fence bracket assembly and set it aside.

7.Using two 8mm wrenches, adjust the inward stop bolt (see Figure 26) until it hits the fence at precisely 45º inward, then tighten the jam nut (where the bolt meets the bracket assem- bly) while holding the stop bolt in place. Some trial-and-error will be required to set this stop correctly.

Inward

Stop Bolt

Figure 26. Adjusting the inward stop.

-20-

G0612 6" Jointer

Image 22
Contents Model G0612 Jointer Page Table of Contents Foreword IntroductionContact Info Machine Data Sheet Identification Safety Safety Instructions for MachineryAlways Lock Mobile Bases if Used Before Operating Machinery Additional Safety for Jointers Circuit Requirements 110V OperationItems Needed for Setup SetupSetup Safety Unpacking QtyInventory Jointer Box Contents QtyHardware Not Shown Qty Site Considerations CleanupMounting the Jointer Components and Hardware Needed Qty Attaching the Fence SupportTo attach the fence support To install the fence Installing the FenceFence Tilting Handle Checking Outfeed Table Alignment To adjust the height of the cutterhead knivesTo check the outfeed table alignment To Install the dust collection chute and bag Dust CollectionTest Run Attaching the dust collection bagOperations Operation SafetyBasic Parts Controls Page Fence Angle Stops To set the 90º stopAdjusting the inward stop G0612 6 Jointer To set the inward 45º stopTo set the outward 45º stop Stock Inspection Requirements Squaring Stock Surface Planing To surface plane on the jointerEdge Jointing To edge joint on the jointerBevel Cutting To bevel cut on the jointerH1300 G7984 H2347 H0736 AccessoriesH1298 G3631-Jointer/Planer Knife HoneH1411-PowerHandsSafety Stick Half-mask respirator and disposable Cartridge filtersSchedule MaintenanceCleaning BeltsService TroubleshootingPage To realign or replace the cutterhead belt Adjusting/Replacing BeltsTo replace the fan belt Replacing Motor Brushes To replace motor brushesWiring Diagram Parts Breakdown Parts List Safety Label Parts List DescriptionWarranty and Returns Warranty Card CommentsGrizzly INDUSTRIAL, INC BOX BELLINGHAM, WAPage Call Today For a Free Full Color Catalog