SECTION 3: CIRCUIT REQUIREMENTS
Amperage Draw |
| |
|
|
|
|
|
|
The Model G0526 features a 110V/220V motor that is prewired at 110V.
Amperage Draw |
|
|
|
110V (prewired) | 18 | Amps | |
220V | 9 | Amps | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
The cord set enclosed is equipped with a NEMA
Circuit Breaker
Use the following guidelines when choosing a cir- cuit breaker (circuit breakers rated any higher are not adequate to protect the circuit):
Circuit Breaker |
|
|
110V (prewired) | 20 Amp, 1 Pole | |
220V | 10 Amp, 2 Pole | |
|
|
|
|
|
|
|
|
|
|
|
|
Figure 1a. NEMA 5-15 plug and receptacle.
If the jointer is rewired to operate on a 220V power source, the plug must be replaced with a NEMA 6-15 plug (Figure 1b).
Figure 1b. NEMA 6-15 plug and receptacle.
G0526 6" Jointer |