| Remote 14 Receptacle Information |
|
| ||||
|
|
|
|
| Socket* | Socket Information | |
|
|
|
| 24 VOLTS AC | A | 24 volts ac. Protected by circuit breaker CB2. | |
|
|
|
|
|
| ||
A |
| J |
| B | Contact closure to A completes 24 volts ac | ||
K |
|
| contactor control circuit. | ||||
B |
| I |
|
|
| ||
|
|
|
| I | 115 volts ac. Protected by circuit breaker CB1. | ||
C | L N | H | 115 VOLTS AC | ||||
|
| ||||||
D |
| M | G |
| J | Contact closure to I completes 115 volts ac | |
|
| E | F |
|
| contactor control circuit. | |
|
|
|
|
| C | Output to remote control; 0 to +10 volts dc, +10 | |
|
|
|
|
|
| volts dc in MIG mode. | |
|
|
|
| REMOTE | D | Remote control circuit common. | |
|
|
|
| OUTPUT | E | 0 to +10 volts dc input command signal from | |
|
|
|
| CONTROL | |||
|
|
|
|
|
| remote control. | |
|
|
|
|
| M | CC/CV select | |
|
|
|
| A/V | F | Current feedback; +1 volt dc per 100 amperes. | |
|
|
|
|
|
| ||
|
|
|
| AMPERAGE | H | Voltage feedback; +1 volt dc per 10 output recep- | |
|
|
|
| VOLTAGE |
| tacle volts. | |
|
|
|
|
| G | Circuit common for 24 and 115 volts ac circuits. | |
|
|
|
| GND | K | Chassis common. | |
|
|
|
|
|
*The remaining sockets are not used.
1 115 V 10 Amp AC Receptacle
Power is shared between duplex receptacle and Remote 14 recep- tacle (see Section
1 | 2 Circuit Breaker CB1 |
3 Circuit Breaker CB2
CB1 protects duplex receptacle and 115 volts ac portion of Remote 14 receptacle from overload.
CB2 protects 24 volts ac portion of Remote 14 receptacle from overload.
Press button to reset breaker.
2 3
803