Positoning Jumper Links (230/400V | |
| 230 V |
| 400 V |
3-7. Electrical Service Guide
Migmatic Model | 271 |
| 273 |
| 293 |
| 333 |
| 383 | ||||
|
|
|
|
|
|
|
|
|
|
|
|
| |
Input Voltage | 230 | 230 |
| 400 | 230 |
| 400 | 230 |
| 400 | 230 |
| 400 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Input Amperes at Rated Output | 35 | 23 |
| 13 | 30 |
| 18 | 32 |
| 19 | 38 |
| 22 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Max Recommended Standard Fuse |
|
|
|
|
|
|
|
|
|
|
|
|
|
or Circuit Breaker Rating in Am- | 35 | 23 |
| 13 | 30 |
| 18 | 32 |
| 19 | 38 |
| 22 |
peres |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
** Input Conductor Size in mm2 | 4 | 2.5 |
| 2.5 | 6 |
| 4 | 6 |
| 4 | 6 |
| 4 |
** Grounding Conductor Size in | 4 | 2.5 |
| 2.5 | 6 |
| 4 | 6 |
| 4 | 6 |
| 4 |
mm2 |
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
** Power cord supplied with the unit is sized for 230V operation. Larger power cord may be required for cable lengths greater than 3 meters. Consult national and local regulations.