Single-Phase Units

Table 14 — 48HJ006 Fan Performance — Vertical Discharge Units With Standard Motor

Single-Phase Units

AIRFLOW

 

 

 

 

 

 

 

 

 

EXTERNAL STATIC PRESSURE (in. wg)

 

 

 

 

 

 

 

 

 

0.1

 

0.2

 

0.4

 

0.6

 

0.8

 

1.0

 

1.2

 

1.4

 

1.6

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

Rpm

 

Bhp

Rpm

 

Bhp

Rpm

 

Bhp

Rpm

 

Bhp

Rpm

 

Bhp

Rpm

 

Bhp

Rpm

 

Bhp

Rpm

 

Bhp

Rpm

 

Bhp

1500

771

 

0.37

828

 

0.44

935

 

0.58

1027

 

0.73

1107

 

0.88

1185

 

1.04

1257

 

1.20

1330

 

1.38

1411

 

1.59

1600

816

 

0.45

869

 

0.51

968

 

0.66

1056

 

0.81

1127

 

0.97

1215

 

1.14

1286

 

1.31

1353

 

1.49

1421

 

1.68

1700

902

 

0.61

940

 

0.60

1007

 

0.75

1094

 

0.91

1175

 

1.09

1245

 

1.26

1315

 

1.44

1381

 

1.52

1443

 

1.69

1800

942

 

0.70

978

 

0.66

1063

 

0.82

1147

 

0.97

1248

 

1.20

 

 

 

1395

 

1.46

1475

 

1.56

1542

 

1.71

 

 

 

 

 

1322

 

1.33

 

1900

982

 

0.80

1023

 

0.78

1097

 

0.91

1175

 

1.11

1266

 

1.29

1356

 

1.47

1430

 

1.58

1504

 

1.69

1556

 

1.82

2000

1022

 

0.91

1068

 

0.90

1132

 

1.01

1218

 

1.23

1303

 

1.41

1397

 

1.52

1459

 

1.67

1532

 

1.82

1588

 

1.97

2100

1063

 

0.99

1115

 

1.00

1180

 

1.17

 

 

 

1340

 

1.53

1428

 

1.66

1489

 

1.80

1567

 

1.99

1626

 

2.16

 

 

 

1261

 

1.35

 

2200

1104

 

1.13

1159

 

1.15

1214

 

1.28

1310

 

1.52

1375

 

1.63

1459

 

1.80

1528

 

1.95

1603

 

2.17

1666

 

2.37

2300

1130

 

1.26

1202

 

1.29

1248

 

1.38

1358

 

1.69

1410

 

1.72

1488

 

1.93

1561

 

2.13

1637

 

2.35

1710

 

2.54

2400

 

 

 

 

 

 

1292

 

1.55

1392

 

1.81

1460

 

1.90

1532

 

2.14

1584

 

2.28

1671

 

2.55

1756

 

2.70

1174

 

1.37

1237

 

1.41

 

2500

1201

 

1.48

1272

 

1.53

1335

 

1.71

1427

 

1.94

1518

 

2.16

1575

 

2.35

1633

 

2.53

1698

 

2.72

 

 

 

 

 

 

 

 

 

 

 

3-Phase Units

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIRFLOW

 

 

 

 

 

 

 

 

 

EXTERNAL STATIC PRESSURE (in. wg)

 

 

 

 

 

 

 

 

 

0.1

 

0.2

 

0.4

 

0.6

 

0.8

 

1.0

 

1.2

 

1.4

 

1.6

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

Rpm

 

Bhp

Rpm

 

Bhp

Rpm

 

Bhp

Rpm

 

Bhp

Rpm

 

Bhp

Rpm

 

Bhp

Rpm

 

Bhp

Rpm

 

Bhp

Rpm

 

Bhp

1500

771

 

0.37

828

 

0.44

935

 

0.58

1027

 

0.73

1107

 

0.88

1185

 

1.04

1257

 

1.20

1330

 

1.38

1411

 

1.59

1600

816

 

0.45

869

 

0.51

968

 

0.66

1056

 

0.81

1127

 

0.97

1215

 

1.14

1286

 

1.31

1353

 

1.49

1421

 

1.68

1700

902

 

0.61

940

 

0.60

1007

 

0.75

1094

 

0.91

1175

 

1.09

1245

 

1.26

1315

 

1.44

1381

 

1.52

1443

 

1.69

1800

942

 

0.70

978

 

0.66

1063

 

0.82

1147

 

0.97

1248

 

1.20

1322

 

1.33

1395

 

1.46

1475

 

1.56

1542

 

1.71

1900

982

 

0.80

1023

 

0.78

1097

 

0.91

1175

 

1.11

1266

 

1.29

1356

 

1.47

1430

 

1.58

1504

 

1.69

1556

 

1.82

2000

1022

 

0.91

1068

 

0.90

1132

 

1.01

1218

 

1.23

1303

 

1.41

1397

 

1.52

1459

 

1.67

1532

 

1.82

1588

 

1.97

2100

1063

 

0.99

1115

 

1.00

1180

 

1.17

1261

 

1.35

1340

 

1.53

1428

 

1.66

1489

 

1.80

1567

 

1.99

1626

 

2.16

2200

1104

 

1.13

1159

 

1.15

1214

 

1.28

1310

 

1.52

1375

 

1.63

1459

 

1.80

1528

 

1.95

1603

 

2.17

1666

 

2.37

2300

1130

 

1.26

1202

 

1.29

1248

 

1.38

1358

 

1.69

1410

 

1.72

1488

 

1.93

1561

 

2.13

1637

 

2.35

 

 

 

 

 

 

 

 

 

 

 

1710

 

2.54

2400

1174

 

1.37

1237

 

1.41

1292

 

1.55

1392

 

1.81

1460

 

1.90

1532

 

2.14

1584

 

2.28

1671

 

2.55

1756

 

2.70

2500

1201

 

1.48

1272

 

1.53

1335

 

1.71

1427

 

1.94

1518

 

2.16

1575

 

2.35

1633

 

2.53

1698

 

2.72

 

Table 15 — 48HJ006 Fan Performance — Vertical Discharge Units With High-Static Motor

AIRFLOW

 

 

 

 

 

 

 

EXTERNAL STATIC PRESSURE (in. wg)

 

 

 

 

 

 

 

0.2

 

 

 

0.4

 

 

 

 

0.6

 

 

 

 

0.8

 

 

1.0

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

Bhp

 

Rpm

 

Bhp

 

Rpm

 

Bhp

Rpm

 

Bhp

Rpm

 

 

Bhp

1500

808

 

0.42

 

 

914

 

0.56

 

1001

 

0.69

1084

 

 

0.85

 

1168

 

 

1.01

1600

846

 

0.49

 

 

950

 

0.64

 

1034

 

0.78

1111

 

 

0.94

 

1194

 

 

1.11

1700

884

 

0.57

 

 

983

 

0.72

 

1068

 

0.88

1145

 

 

1.03

 

1218

 

 

1.21

1800

924

 

0.66

 

 

1018

 

0.82

 

1105

 

0.98

1179

 

 

1.13

 

1246

 

 

1.32

1900

965

 

0.76

 

 

1057

 

0.92

 

1143

 

1.10

1212

 

 

1.26

 

1280

 

 

1.43

2000

1008

 

0.87

 

 

1096

 

1.04

 

1177

 

1.22

1247

 

 

1.40

 

1300

 

 

1.57

2100

1051

 

0.99

 

 

1136

 

1.17

 

1210

 

1.35

1284

 

 

1.54

 

1347

 

 

1.72

2200

1095

 

1.12

 

 

1173

 

1.30

 

1245

 

1.49

1322

 

 

1.70

 

1380

 

 

1.89

2300

1140

 

1.26

 

 

1210

 

1.47

 

1284

 

1.65

1356

 

 

1.80

 

1418

 

 

2.07

2400

1185

 

1.41

 

 

1249

 

1.61

 

1323

 

1.80

1389

 

 

2.03

 

1456

 

 

2.26

2500

1231

 

1.57

 

 

1289

 

1.78

 

1363

 

2.00

1424

 

 

2.22

 

1500

 

 

2.45

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIRFLOW

 

 

 

 

 

 

 

EXTERNAL STATIC PRESSURE (in. wg)

 

 

 

 

 

 

 

 

1.2

 

 

 

1.4

 

 

 

 

1.6

 

 

 

1.8

 

 

 

 

2.0

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

 

Bhp

 

Rpm

 

Bhp

 

Rpm

 

Bhp

 

 

Rpm

 

 

Bhp

 

Rpm

 

 

Bhp

1500

 

1199

 

1.19

 

1126

 

1.46

 

1250

 

1.69

 

 

1301

 

1.91

 

1349

 

2.12

1600

 

1263

 

1.28

 

1275

 

1.49

 

1299

 

1.78

 

 

1352

 

2.01

 

1401

 

2.23

1700

 

1295

 

1.39

 

1351

 

1.58

 

1352

 

1.80

 

 

1407

 

2.03

 

1459

 

2.26

1800

 

1319

 

1.52

 

1389

 

1.71

 

1435

 

1.91

 

 

1494

 

2.15

 

1548

 

2.40

1900

 

1343

 

1.64

 

1415

 

1.80

 

1478

 

2.05

 

 

1538

 

2.31

 

1594

 

2.57

2000

 

1374

 

1.77

 

1438

 

1.99

 

1505

 

2.21

 

 

1566

 

2.49

 

1624

 

2.77

2100

 

1409

 

1.91

 

1465

 

2.14

 

1533

 

2.45

 

 

1596

 

2.77

 

1654

 

3.08

2200

 

1442

 

2.08

 

1498

 

2.30

 

1568

 

2.64

 

 

 

 

 

 

1691

 

3.31

 

 

1632

 

2.97

2300

 

1475

 

2.26

 

1554

 

2.64

 

1627

 

3.03

 

 

1693

 

3.42

 

1755

 

3.81

2400

 

1565

 

2.47

 

1649

 

2.89

 

1726

 

3.31

 

 

 

 

 

 

 

2500

 

 

 

 

 

 

 

 

 

1760

 

3.96

 

 

 

 

 

 

 

1596

 

2.95

 

1682

 

3.45

 

 

 

 

 

 

LEGEND AND NOTES FOR TABLES 14 AND 15

LEGEND

Bhp — Brake Horsepower Input to Fan

FIOP — Factory-Installed Option

NOTES:

1.Boldface indicates field-supplied drive required. (See Note 3.)

2.3-Phase UnitsManual background indicates field-supplied motor and drive required.

3.Motor drive range is 1020 to 1460 rpm for single-phase standard motors, 1120 to 1585 for 3-phase standard motors, and 1300 to 1685 for high-static motors. All other rpms require a field-supplied drive.

4.Values include losses for filters, unit casing, and wet coils. See page 28 for accessory/FIOP static pressure information.

5.Maximum continuous bhp is 1.30 for single-phase standard motors, 2.40 for 3-phase standard motors, and 2.90 for high-static motors. Extensive motor and electrical testing on these units ensures that the full range of the motor can be utilized with confidence. Using your fan motors up to the ratings shown will not result in nuisance tripping or premature motor failure. Unit warranty will not be affected. See Evaporator-Fan Motor Data tables on page 20 for additional information.

6.Use of a field-supplied motor may affect wire sizing. Contact your Carrier representative to verify.

7.Interpolation is permissible. Do not extrapolate.

23

Page 23
Image 23
Carrier 48HJD005-007 specifications Single-Phase Units