Carrier 48HJD005-007 specifications Base Unit Dimensions - 48HJ004-007, 1/2″, 3/4″

Models: 48HJD005-007

1 48
Download 48 pages 50.36 Kb
Page 7
Image 7
1/2″

 

STANDARD

DURABLADE

 

 

CORNER

CORNER

CORNER

CORNER

BOTTOM POWER CHART, THESE HOLES REQUIRED FOR

 

ECONOMI$ER

USE WITH ACCESSORY PACKAGES — CRBTMPWR001A00

UNIT

UNIT

ECONOMIZER

WEIGHT

WEIGHT

WEIGHT

WEIGHT

WEIGHT

THROUGH CRBTMPWR004A00

48HJ

WEIGHT

WEIGHT

 

 

 

(A)

(B)

(C)

 

(D)

 

 

 

 

Lb

Kg

Lb

Kg

Lb

Kg

Lb

Kg

Lb

Kg

Lb

Kg

Lb

Kg

THREADED

WIRE

REQURED

004

530

240

34

15.4

47

21.3

127

57.6

122

55.3

138

62.6

143

64.9

CONDUIT SIZE

USE

HOLE SIZES (MAX.)

005

540

245

34

15.4

47

21.3

129

58.5

124

56.2

141

64.0

146

66.2

1/2

24 V

7/8[22.2]

006

560

254

34

15.4

47

21.3

134

60.8

129

58.5

146

66.2

151

68.5

3/4

Power*

11/8[28.4]

007

615

279

34

15.4

47

21.3

147

66.7

142

64.4

160

72.6

166

75.3

11/4

Power*

13/4[44.4]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1/2NPT

Gas†

11/4[31.8]

 

CONNECTION SIZES

 

 

 

 

 

 

 

 

 

 

3/4NPT

Gas†

15/8[41.3]

A

13/8Dia [35] Field Power Supply Hole

 

 

 

 

 

 

 

 

 

*Select either 3/4or 11/4for power, depending on wire size.

B

2Dia [51] Power Supply Knockout

 

 

 

 

 

 

 

 

 

 

†Select either 1/2or 3/4for gas depending on gas connection.

C

13/4Dia [44] Charging Port Hole

 

 

 

 

 

 

 

 

 

 

 

 

 

D

7/8Dia [22] Field Control Wiring Hole

 

 

 

 

NOTES:

 

 

 

 

 

E

3/4-14 NPT Condensate Drain

 

 

 

 

 

1.

Dimensions in [

] are in millimeters.

 

 

F

5/8-14 NPT Gas Connection

 

 

 

 

 

2.

 

Center of gravity.

 

 

 

G

21/2Dia [64] Power Supply Knockout

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.

 

Direction of airflow.

 

 

 

 

 

 

 

 

 

 

 

 

 

4. On vertical discharge units, ductwork to be attached to accessory roof curb only. For horizontal dis-

 

 

 

 

 

 

 

 

 

 

 

charge units, field-supplied flanges should be attached to horizontal discharge openings, and all

 

 

 

 

 

 

 

 

 

 

 

ductwork should be attached to the flanges.

 

 

 

 

 

 

 

 

 

 

 

 

5. Minimum clearance (local codes or jurisdiction may prevail):

 

 

 

 

 

 

 

 

 

 

 

 

a. Between unit, flue side and combustible surfaces, 48 inches. (18 in. when using accessory flue

 

 

 

 

 

 

 

 

 

 

 

 

discharge deflector.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b. Bottom of unit to combustible surfaces (when not using curb), 1 inch.

 

 

 

 

 

 

 

 

 

 

 

 

Bottom of base rail to combustible surfaces (when not using curb) 0 inches.

 

 

 

 

 

 

 

 

 

 

 

c. Condenser coil, for proper airflow, 36 in. one side, 12 in. the other. The side getting the greater

 

 

 

 

 

 

 

 

 

 

 

 

clearance is optional.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

d. Overhead, 60 in. to assure proper condenser fan operation.

 

 

 

 

 

 

 

 

 

 

 

 

e. Between units, control box side, 42 in. per NEC (National Electrical Code).

 

 

 

 

 

 

 

 

 

 

 

f. Between unit and ungrounded surfaces, control box side, 36 in. per NEC.

 

 

 

 

 

 

 

 

 

 

 

g. Between unit and block or concrete walls and other grounded surfaces, control box side, 42 in.

 

 

 

 

 

 

 

 

 

 

 

 

per NEC.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

h. Horizontal supply and return end, 0 inches.

 

 

 

 

 

 

 

 

 

 

 

 

6. With the exception of the clearance for the condenser coil and combustion side as stated in notes

 

 

 

 

 

 

 

 

 

 

 

5a, b and c, a removable fence or barricade requires no clearance.

 

 

 

 

 

 

 

 

 

 

 

7. Units may be installed on combustible floors made from wood or Class A, B, or C roof covering

 

 

 

 

 

 

 

 

 

 

 

material if set on base rail.

 

 

 

 

 

 

 

 

 

 

 

 

 

8. The vertical center of gravity is 1-6[457] up from the bottom of the base rail.

Fig. 5 — Base Unit Dimensions — 48HJ004-007

7

Page 7
Image 7
Carrier 48HJD005-007 specifications Base Unit Dimensions - 48HJ004-007, 1/2″, 3/4″