YL/PK

CPG036(048)0901D SINGLE PHASE 240V/60HZ DIRECT DRIVE

HIGH VOLTAGE!

DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS

UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO

DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

 

 

 

 

 

YL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RD

 

 

 

 

 

 

 

RD

 

 

 

 

 

 

BK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BK

 

 

T1

 

 

T2

 

 

GND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COMP

 

BK

 

 

 

BL

 

 

 

 

 

YL

 

 

 

 

 

PU

 

 

 

 

 

L1

C

 

L2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BR

 

 

 

 

 

BL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CM

 

 

 

 

 

BK

 

 

 

208-240/1/60

 

 

 

 

 

 

 

 

 

 

 

 

 

SEE NOTE 5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PU

 

 

 

 

 

 

 

 

 

 

EM

 

BR

BC

 

 

 

 

 

 

 

 

 

 

 

 

3 SPEED

RD

 

 

1

2

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

208

240

 

 

FOR

 

 

 

BL

 

ALTERNATE

 

 

 

TR

 

 

 

 

 

 

 

LS

RD

 

24V

 

 

 

SMOKE/FIRE

 

 

RD

 

MOTOR

PU

 

 

 

 

DETECTOR

 

YL RD

 

 

 

 

 

 

 

 

BK

 

6-WIRES

 

 

 

PK

 

BL

 

 

REPLACE

 

 

 

 

RD

BL

GR

JUMPER

 

YL

PU

 

SEE NOTE 6 & 7

 

 

 

S1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EM

BR

BC

 

 

 

 

 

 

 

PK

 

 

 

3 SPEED

 

 

 

 

 

 

 

 

 

 

 

 

 

PU

 

 

 

 

 

 

 

 

TB1

S2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BL

 

SEE NOTE 7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RD

 

 

 

 

 

 

 

 

 

 

OR

 

 

 

 

 

ALS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PU

 

 

 

 

 

 

 

 

 

 

IIC

 

 

 

 

 

 

 

 

 

 

 

GR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PS

 

YL

 

 

 

 

 

 

 

 

YL

 

 

 

 

 

PU

 

 

 

 

 

 

 

 

 

YL

 

 

 

 

 

 

 

YL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BR

 

NOTE 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PLF

GR

 

 

 

 

 

 

 

 

 

 

 

 

 

RS

 

3

6

 

 

 

 

 

 

 

 

 

 

 

 

 

RD

 

YL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

5

 

 

 

 

 

 

 

 

 

 

 

 

BK

 

1

4

BL

 

 

 

 

 

 

 

 

 

 

 

 

PU

 

 

YL

 

 

 

 

 

 

 

 

 

 

 

 

 

BL

 

(ALT.) HONEYWELL

 

 

 

 

 

 

 

 

 

 

 

 

W. R.

 

 

 

 

 

 

 

 

 

 

 

 

 

GAS VALVE

GAS VALVE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PU

MV

 

 

 

 

 

 

 

BK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GV

 

BL

GV

 

 

 

 

 

 

 

 

 

 

 

YL/PK

LPS

 

 

MV

Y2 W2

C RY1W1 G

 

 

RD

 

 

 

 

 

 

 

 

 

SEE NOTE 8

 

 

 

 

 

 

 

BL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TB1

WH

 

GREEN JUMPER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VM

SEE

FS

RD

 

 

 

 

 

 

 

 

 

 

 

NOTE 9

 

 

 

 

 

 

 

 

 

 

 

 

 

RD

IGN

OR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BK

 

 

 

 

 

 

 

 

 

RCCF

 

BL/PK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HPS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BR

F

H

C

RD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YL

 

 

 

 

 

 

 

 

 

 

 

 

208-240/1/60

0140L00506

REV A

Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. 38